FCC ID:K6630323X30
IC: 511B-30323X30
Vertex Standard Co.,Ltd.
24
Available Values: 00 / 01 / 02 / 03
Default: 02
07 SnL (SCAN LAMP)
Function: Enable/Disable the automatic illumination of the lamp when a signal is received on a
channel during Scanning
Available Values: on / oFF
Default: oFF
08 SCn (SCAN DISPLAY)
Function: Selects the Scanning display mode
Available Values: nor (Normal) / SPL (Special)
Default: nor (Normal)
When this menu is set to “nor (Normal)” the channel numbers during scan will be shown as scrolling
on the display. When “SPL (Special)” is selected the channel numbers on the display do not change
unless a call was received. The channel shown is the last channel that was received.
09 dt (DUAL WATCH MODE)
Function: Selects dual or tri-watch as desired.
Available Values: d- (Dual Watch) / t- (Triple Watch)
Default: d- (Dual Watch)
See page
24 for details.
10 dUL (DW DISPLAY)
Function: Selects the Dual Watch scanning display mode.
Available Values: nor (Normal) / SPL (Special)
Default: nor (Normal)
When “SPL (Special)” is selected the channel shown on the display is the last channel the HX760S
received a call on. This is a handy feature if you cannot look at the radio the moment a transmission
was received.
11 bSY (BUSY LED)
Function: Enable/Disable the BUSY LED while the squelch is open.
Available Values: on / oFF
Default: on