background image

Instructions for Converting to a Permanently Wired Machine 

CAUTION:

The following instructions are intended to be used by a qualified 

electrician.  Local building codes should be checked for compliance.

 

1.

 

Disconnect power to the changer. 

2.

 

Remove hoppers from change machines if needed to access outlet box. 

3.

 

If used remove the two nuts holding cord retaining plate to the cabinet. 

4.

 

Pull the cord through outlet hole into the cabinet. 

5.

 

The hole in the cabinet is sized for 1-inch conduit fittings.  Some models have several 
cutouts allowing alternate wiring inlets. 

6.

 

Install conduit and supply lines (

NOTE:

for outdoor locations use water tight conduit 

and fittings). It is important to the operation of your changer that wiring be in 
properly grounded electrical conduit. (3

rd

wire ground back to the main service panel) 

We also recommend that the changer be wired on a dedicated line.  A dedicated line 
is a circuit which has no other equipment connected on the same circuit breaker or 
fuse.  The purpose of a dedicated line is to reduce the possibility of interference, 
which may cause the changer to malfunction. 

7.

 

Remove the screws from the outlet box cover.

8.

 

Pull the cover out to access the terminal block inside the box and disconnect the cord 
from the terminal block. No other wires should be removed. 

9.

 

Remove the power cord from the outlet box. 

10.

 

Route new supply line through cabinet to the outlet box supply line should be kept 
away from all low voltage cable to reduce risk of EMI interference. 

11.

 

The electrical connections should be as follows: 
 
The Neutral line (White wire) from the supply line must be connected to the White or 
Blue (Filter only) wire at the terminal block. 
 
The Hot Line (Black wire) from the supply line must be connected to the Black or 
Brown (Filter only) wire at the terminal block. 
 
The Ground (bare/green) supply line wire must be connected to the Green wire at the 
terminal block. 
 

12.

 

Reinstall cover onto outlet box. 

13.

 

With power OFF use an ohmmeter to check the connections making sure there are no 
shorts to the cabinet except for the ground connection and that hot and neutral are not 
shorted together. 

14.

 

Power on machine. 

15.

 

Test machine for proper operation. 

IMPORTANT NOTE: 

 
A WORD ABOUT GROUNDING 

Please insure your changer has a good ground.  Improper grounding of the changer will cause erratic 
operation and is unsafe for the people using the changer. 

 

Содержание BCX-FRONT

Страница 1: ...RNING Welding the cabinet to any kind of mounting could cause damage to electrical components within the machine Warping of the cabinet may also occur Welding of any kind to the cabinet during installation will void the manufacturer s warranty If welding is ultimately necessary all components within the machine must be removed prior to welding Please contact our Service Department with any questio...

Страница 2: ... straps from inside the cabinet Some items have yellow tags with removal instructions Outdoor Installations All Cabinets This machine can be used in protected outdoor locations Standard Change Makers Inc recommends the use of an awning canopy marquee or other protective screen to prevent machine damage from exposure to weather Caution Important Any open mounting holes in the top or sides of the ca...

Страница 3: ...pproximately the same dimensions as the changer should be welded to the post Bolt the changer to the steel plate through the four 1 4 inch mounting holes drilled into the plate Tack weld the heads of the mounting bolts to prevent their removal Four nuts and washers inside the changer can then secure the changer If this method is not feasible the bolts can be bent after installation to prevent remo...

Страница 4: ... the faceplate to cabinet joint so that when the changer is slid through the wall opening a tight weather poof seal is formed Any deviation of these guidelines will void the machine s warranty Installing Stand Mounted Changers Stand mounted changers can be mounted in between or with other vending machines Optional cap kits are available to make the changer the same height as other vending machines...

Страница 5: ...ger to malfunction Some models have several cut outs allowing alternate wiring inlets For outdoor locations permanent wiring is required See instructions below Important Note NOTE TEMPORARY HOOKUPS never allow access to the power plugs Power cable feed should not exceed 100 Feet in length NOTE An improperly connected machine may void your warranty NOTE Permanent outdoor installations require the u...

Страница 6: ...nger to malfunction 7 Remove the screws from the outlet box cover 8 Pull the cover out to access the terminal block inside the box and disconnect the cord from the terminal block No other wires should be removed 9 Remove the power cord from the outlet box 10 Route new supply line through cabinet to the outlet box supply line should be kept away from all low voltage cable to reduce risk of EMI inte...

Страница 7: ... include a second supply may require up to 160 Watts momentarily Ancillary items can increase the overall machine power consumption requirement An example would be the power consumption of a heater kit The power consumption of this device device draws 100 load when on is equal to the wattage of the heating element A 100 Watt heating element in addition to the momentary power supply draw of 80W wou...

Страница 8: ...TRAL and GROUND terminals a volt ohmmeter should indicate no more than 5 volts AC Readings greater than 5 volts AC indicate a poor grounding condition that could result in noise problems for the electronic circuitry If you are hard wiring the changer the same checks should be performed on the supply line going to the changer Any deviation from these requirements may result in unreliable performanc...

Страница 9: ...ver that protects the machine from direct exposure to sunlight and the elements is strongly recommended This simple precaution will not only reduce maintenance issues for the changer s major operating components it will also increase the potential operating life of the machine For climates that see sustained temperatures below the previously defined moderate levels 0o C 32o F an optional Heater Ki...

Страница 10: ...f the door when opened for removing and replenishing revenues User Access Easily accessed by customers and proper height from the floor The height will vary depending upon the changer model Accessibility for the handicapped as required by the Americans with Disabilities Act ADA specifies that all controls coin cup coin insertion slots and bill acceptor slots shall not be higher than 48 1220 mm or ...

Страница 11: ...MC350RL TIK 20 00 20 00 NA NA MC400RL 30 50 26 00 NA NA MC500RL DA 25 00 25 00 NA NA MC520 RL 28 00 24 50 NA NA MC525 535RL CC 28 00 24 50 NA NA MC600RL DA 25 00 25 00 NA NA MC700 Series 30 50 30 50 26 625 13 625 MC720 CC 30 50 30 50 26 625 13 625 MC720 CC with printer 26 625 26 625 26 625 13 625 MC800 DA 26 00 26 00 26 00 NA MC900 DA Console NA NA 6 030 BX FRONT FUJ 30 00 NA 30 00 14 00 BX REAR F...

Страница 12: ... used and a printer is added at a later date then the machine would no longer meet ADA Requirements Test the Machine Operation When installation is complete test each machine function for proper payout and operation 1 Fill the hoppers until the black area at the bottom is covered 2 Insert monetary bills in the bill acceptor 3 Count the coins dispensed FOR ADDITIONAL QUESTIONS OR ASSISTANCE IN INST...

Отзывы: