Texmate, Inc. Tel. (760) 598-9899

A Versatile Event Counter/Totalizer Featuring 19999 Counts with Overrange Indication, or 9999 Counts with Cascade 

Output, Contact Closure or Logic Signal Input, High Contrast LCD, 4-6 V DC Powered with Outputs for User Supplied 

NI-CAD Battery Back-Up, Capable of Signal Powered Operation. 

PC-45X  

4 1/2 DIGIT 

EVENT COUNTER

ORDERING INFORMATION

Order Part No.

 

 

 

 

               

STANDARD 1999 COUNTS EVENT COUNTER 

   PC-45X

ACCESSORIES: Edge Connector (20 pin solder tabs)

  

CN-L10

DESCRIPTION

Texmate's model PC-45X event counter/totalizer 

is a versatile, low cost DC powered LCD meter which 

features three user programmable count inputs and 

count rates. All count inputs are compatible with open 

collector sensing devices. The standard low range 

SPST or SPDT dry contact closure rate is 0~6000 CPM 

(0~100 CPS). The SPST switch input mode utilizes a low 

pass filter and a Schmitt trigger with 15% hysteresis for 

debouncing. The SPS T switch input mode which utilizes 

an R-S Flip-Flop for debouncing can accept high speed 

dry contact closure rates of 0~600,000 CPM (0~10,000 

CPS) if the low pass filter is reduced or eliminated. The 

PC-45X also accepts 3-30VDC positive going pulses 

or AC signal inputs up  to 15MHz. A 500mV hysteresis 

aids the accurate counting of slow changing waveforms.

Other features include logic controls such as inhibit, 

reset, display hold, carry output, overrange output, and 

outputs to continuously trickle charge an external user 

supplied Ni-Cad battery back-up which will prevent loss 

of data in case of intermittent or power-out situations.  

The unit is also capable of being programmed for sig-

nal powered operation. There are four programmable 

decimal points, and unlimited cascading to achieve 

multiples of four digits using two or more PC-45X units. 

In this type of operation only the left most meter will 

display a fifth digit. 

The display hold feature enables the user to latch 

the display while the counter continues counting. With-

out affecting the latched display, the counter may be 

reset to zero by the reset control or the counting function 

may be stopped and started by the inhibit control. When 

the Display Hold is released, the data present in the 

counter at that time is instantly displayed.

With external logic control, the PC-45X may be 

used as a frequency counter, RPM indicator or period 

counter. The large 0.48" LCD display has excellent read-

ability in both high and low ambient light conditions, 

and its low power consumption 5VDC-2mW or signal 

powered operation makes it especially useful in remote 

locations.

When PC-45X is programmed for signal powered 

operation (9 to 600V p-p @ 400µA), the back-up bat-

tery must be used unless the input signal pulses are 

continuous because power is required to maintain the 

count logic.

SPECIFICATIONS

COUNT INPUTS

SPST Contact Closure

:   0~6000 CPM (100Hz) with 500Hz Low Pass  

 

filter and Schmitt Trigger set at 15%  

 

 Hysteresis

SPDT Contact Closure

:   0~6000 CPM (100Hz) with 500Hz  Low Pass  

 

filter and R-S Flip-Flop.  0~600,000 CPM    

 

(10kHz) with filter removed

3-30V AC or DC Pulse:

  

0~500kHz with Schmitt Trigger threshold   of  

 

2V and 500mV Hysteresis. If the internal

 

100kΩ overvoltage protection resistor is    

 

removed the max count is 0~15MHz

Open Collector Sensing:

   All inputs are compatible with open collector  

 

sensing devices

Over Voltage Protection:

   Pins 6, E & F are protected up to ±100V peak  

 

overload with internal 100kΩ resistors.

 

Caution:

 All other input or control pins are  

 

  NOT PROTECTED against High Voltage.

CONTROLS & OUTPUTS

Reset:

  

Dry Switch closure to ground or Logic Low "0"  

 

input for min. 3µS resets counter to zero.    

 

(50µA pull-up current is provided).

Inhibit Count: 

 

Dry Switch closure to ground or Logic Low "0"  

 

input will prevent the D flip-flop on the count  

 

input from operating (10µA pull-up current is  

 provided)

Display Hold: 

 

An Open input or Logic High "1" input on this  

 

pin "freezes" the display while the counter   

 

continues to operate independently. A Dry   

 

Switch closure to ground or Logic low "0" input  

 

for min. 3µS updates the display (10µA pull up  

 

current is provided.) For continuous display of  

 

the counter input the display hold function   

 

should be connected to ground 

Carry Output

Internal solder pad SP2 provides a logic signal  

 

ouput that occurs each 10,000 counts for cas- 

 

cading the count in 4 digit mutilples

Overrange Output

:  

Internal solder pad SP1 goes to Logic High "1"  

 

when the count exceeds  20,000 counts

Display: 

0.48" LCD Max. 19999

Decimal:

 

User programmable to 4 positons

Overload Indications:

 

All digits blank except decimal points

Back-Up Battery: 

 

200µA output is provided to trickle charge a  

 

user supplied 3.6V Ni-Cad battery

Power Requirements

Regulated 4VDC to 6VDC at 400µA or Signal  

 Powered

Operating Temperature:   -20˚C to +60˚C