For rear load changers it may be necessary to temporally remove the power cord to make 
installation of the cabinet easier.  Cover or remove the hoppers to prevent debris or metal 
shavings from falling into the hopper mechanisms. To remove the cord, locate the cord 
retaining plate on the inside of the changer cabinet.  Remove the two nuts securing the 
cord to the inside of the changer.  Pull the cord into the inside of the changer.  After 
installing the cabinet, reverse the directions above to return the cord to its correct 
location. 

For Outdoor locations 

Use  either  silicone  or  RTV  caulking  for  a  watertight  fitting.    Place  a  large  continuous 
bead of caulking on the backside of the front plate around the changer cabinet and fill gap 
around  the  faceplate  to  cabinet  joint  so  that  when  the  changer  is  slid  through  the  wall 
opening a tight weather poof seal is formed.    
 

Any deviation of these guidelines will void the machine’s warranty. 
 

Installing Stand Mounted Changers 

Stand  mounted  changers  can  be  mounted  in  between  or  with  other  vending  machines. 
Optional  cap  kits  are  available  to  make  the  changer  the  same  height  as  other  vending 
machines. The changer is bolted to the stand (four mounting holes) and the stand can be 
bolted to the floor (four mounting holes) or to the wall for maximum security and safety.  
A floor template is included with the stand. 

WARNING: 

CHANGERS  MOUNTED  ON  THE  BASES  ARE  TOP  HEAVY.    The 

changer  must  be  secured  to  a  rigid  vertical  surface,  as  well  as  to  the  stand  to  provide 
appropriate security, stability, and safety. 

Figure 2 

Angle Iron to Secure 
Cabinet Sides 

Steel Shelf with
Steel Support Poles 

Angle Iron to Secure 
Cabinet Sides 

CINDER BLOCK WALL 

2 x 4 WALL

Содержание BCX-FRONT

Страница 1: ...RNING Welding the cabinet to any kind of mounting could cause damage to electrical components within the machine Warping of the cabinet may also occur Welding of any kind to the cabinet during installation will void the manufacturer s warranty If welding is ultimately necessary all components within the machine must be removed prior to welding Please contact our Service Department with any questio...

Страница 2: ... straps from inside the cabinet Some items have yellow tags with removal instructions Outdoor Installations All Cabinets This machine can be used in protected outdoor locations Standard Change Makers Inc recommends the use of an awning canopy marquee or other protective screen to prevent machine damage from exposure to weather Caution Important Any open mounting holes in the top or sides of the ca...

Страница 3: ...pproximately the same dimensions as the changer should be welded to the post Bolt the changer to the steel plate through the four 1 4 inch mounting holes drilled into the plate Tack weld the heads of the mounting bolts to prevent their removal Four nuts and washers inside the changer can then secure the changer If this method is not feasible the bolts can be bent after installation to prevent remo...

Страница 4: ... the faceplate to cabinet joint so that when the changer is slid through the wall opening a tight weather poof seal is formed Any deviation of these guidelines will void the machine s warranty Installing Stand Mounted Changers Stand mounted changers can be mounted in between or with other vending machines Optional cap kits are available to make the changer the same height as other vending machines...

Страница 5: ...ger to malfunction Some models have several cut outs allowing alternate wiring inlets For outdoor locations permanent wiring is required See instructions below Important Note NOTE TEMPORARY HOOKUPS never allow access to the power plugs Power cable feed should not exceed 100 Feet in length NOTE An improperly connected machine may void your warranty NOTE Permanent outdoor installations require the u...

Страница 6: ...nger to malfunction 7 Remove the screws from the outlet box cover 8 Pull the cover out to access the terminal block inside the box and disconnect the cord from the terminal block No other wires should be removed 9 Remove the power cord from the outlet box 10 Route new supply line through cabinet to the outlet box supply line should be kept away from all low voltage cable to reduce risk of EMI inte...

Страница 7: ... include a second supply may require up to 160 Watts momentarily Ancillary items can increase the overall machine power consumption requirement An example would be the power consumption of a heater kit The power consumption of this device device draws 100 load when on is equal to the wattage of the heating element A 100 Watt heating element in addition to the momentary power supply draw of 80W wou...

Страница 8: ...TRAL and GROUND terminals a volt ohmmeter should indicate no more than 5 volts AC Readings greater than 5 volts AC indicate a poor grounding condition that could result in noise problems for the electronic circuitry If you are hard wiring the changer the same checks should be performed on the supply line going to the changer Any deviation from these requirements may result in unreliable performanc...

Страница 9: ...ver that protects the machine from direct exposure to sunlight and the elements is strongly recommended This simple precaution will not only reduce maintenance issues for the changer s major operating components it will also increase the potential operating life of the machine For climates that see sustained temperatures below the previously defined moderate levels 0o C 32o F an optional Heater Ki...

Страница 10: ...f the door when opened for removing and replenishing revenues User Access Easily accessed by customers and proper height from the floor The height will vary depending upon the changer model Accessibility for the handicapped as required by the Americans with Disabilities Act ADA specifies that all controls coin cup coin insertion slots and bill acceptor slots shall not be higher than 48 1220 mm or ...

Страница 11: ...MC350RL TIK 20 00 20 00 NA NA MC400RL 30 50 26 00 NA NA MC500RL DA 25 00 25 00 NA NA MC520 RL 28 00 24 50 NA NA MC525 535RL CC 28 00 24 50 NA NA MC600RL DA 25 00 25 00 NA NA MC700 Series 30 50 30 50 26 625 13 625 MC720 CC 30 50 30 50 26 625 13 625 MC720 CC with printer 26 625 26 625 26 625 13 625 MC800 DA 26 00 26 00 26 00 NA MC900 DA Console NA NA 6 030 BX FRONT FUJ 30 00 NA 30 00 14 00 BX REAR F...

Страница 12: ... used and a printer is added at a later date then the machine would no longer meet ADA Requirements Test the Machine Operation When installation is complete test each machine function for proper payout and operation 1 Fill the hoppers until the black area at the bottom is covered 2 Insert monetary bills in the bill acceptor 3 Count the coins dispensed FOR ADDITIONAL QUESTIONS OR ASSISTANCE IN INST...

Отзывы: