S-WIGMA 225PMH S-WIGMA 255PMH
Input voltage
230V, 1-Phase
230V, 1-Phase
Frequency (Hz)
50Hz
50Hz
Input voltage
T 17A
T 20A
Open circuit voltage
40V
60V
Degree of protection for the
housing
IP21S
IP21S
Insulation class
F
F
Overvoltage protection
yes
yes
Cooling
fan
fan
Gas-magnetic valve
yes
yes
Duty cycle WIG
ED 225A/ 60%
ED 255A/ 60%
Duty cycle WIG
ED 163A/ 100%
ED 187A/ 100%
Welding current AC WIG
5 - 225A
5 - 255 A
Welding current E-Hand
5 - 225A
5 - 255A
Ignition WIG
HF
HF
Ignition MMA
Contact
Contact
Electrode diameter WIG
1 - 3,2mm
1 - 3,2mm
Electrode diameter MMA
1 - 4mm
1 - 4mm
Gas after-flow
1 - 10Sec.
1 - 10Sec.
Current reduction (Down
Slope)
0-10 s
0-10 s
Base current
10-90%
10-90%
Welding thickness
0,3 - 8 mm
0,3 - 10 mm
Pulse current
10 - 225A
10 - 255A
Pulse width
0,1 - 0,9 (10 - 90%)
0,1 - 0,9 (10 - 90%)
Pulse frequency
0,5 - 300Hz
0,5 - 300Hz
Hot-Start/Anti-Stick
yes
yes
Weight
13,2 kg
20 kg
Dimension (LxBxH)
440x218x355
555x220x355
Technical details
START-UP
A. Unpacking
Unpack all items from the package and ensure that all items, specified within the
scope of the delivery are present.
B. Work environment
It is necessary to ensure well ventilation within the working area. The device is cooled
by the fan which ensures cooling for all internal subassemblies of the device.
(Tip! The guards must be installed in such way that the vent holes could be located
at the front side of the device) In order to leave some space for cleaning and cooling,
the device should be located within the distance of at least 15 cm (from each side)
from other objects. If the device is not efficiently cooled, the make-time decreases.
C. Conduits connection
Each device is equipped with feeder cable which supplies it with electric voltage. If
the device is connected to the current source with the voltage exceeding supply
rated voltage or improper phase is connect, it may result in serious damage of the
machine. The device which has been damages in such course does not subject to
repair under the warranty terms.
D. WIG-welding
The handle has to be take by the hand. Unto the black closing cap. Next, it is necessa-
ry to insert wolframic electrode into the collet. Next put the housing onto the collet
and tighten the holder head (Nozzle).
EN