31
•
The Manoskop
®
may not be used for
uncontrolled loosening of nuts & bolts
— for example rusty joints. This may
cause damage to the torque wrench.
Correct torque settings ...
... can be lifesaving in some applications.
For this reason, please note the following
points:
Unless internal regulations at the place of
use say otherwise (e.g. test equipment
inspection to ISO 9000 et seq.) inspection
should take place after approx. 5000 uses
or every 12 months, whichever is the
shorter.
If an inspection shows that there is
excessive deviation, the torque wrench
will have to be readjusted (see page 44).
Additional important safety
points ...
... may apply depending on the
application. These are found in the
appropriate sections marked with danger
symbols
ã
.
ã
C A U T I O N !
In order to ensure the
cut-out is working
accurately, it should be
checked at regular
intervals.