Maintenance and repair
10.1 Maintenance
• Consult the relevant national regulations to determine the type and extent
of inspections.
• Adapt inspection intervals to the operating conditions.
During maintenance of the device, check at least:
• if the cables have been clamped properly;
• the enclosure, seals and surface of the plug pins for damage;
• sleeves for pollution;
• compliance with the permitted temperatures;
• if the device is used in accordance with its designated use.
10.2 Maintenance
10.3 Repair
CAUTION
Danger of electric shock due to energised parts!
Non-compliance can result in minor injuries!
• All connections must be disconnected from the power supply.
• Secure the connections against unauthorized switching.
DANGER
Overheating and explosion hazard due to defective switching contacts!
Non-compliance results in severe or fatal injuries.
• Replace the entire socket flange after each short circuit in the main
circuit of the switch because the state of the switching contacts cannot
be checked in hermetically sealed equipment.
Observe the relevant national regulations in the country of use.
DANGER
Explosion hazard due to improper repair!
Non-compliance results in severe or fatal injuries.
• Repair work on the devices must be performed only by
R. STAHL Schaltgeräte GmbH.