Safety Notes 

5

SolConeX Wall-Mounted Socket, 32 A

Series 8571/11

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN

3

Safety Notes

3.1

Operating Instructions Storage

• Read the operating instructions carefully and store them at the mounting location of 

the device.

• Observe applicable documents and operating instructions of the devices to be 

connected. 

3.2

Safe Use

• Read and observe the safety instructions in these operating instructions!

• Use the cable gland in accordance with its intended purpose only.

• We cannot be held liable for damage caused due to incorrect or unauthorized use or 

non-compliance with these operating instructions.

• Before installation and commissioning, make sure that the device is not damaged.

• Work on the cable gland (installation, maintenance, overhaul, repair) may only be 

carried out by appropriately authorized and trained personnel.

• During installation and operation observe the information (characteristic values and 

rated operating conditions) on the rating and data plates and the information plates 

located on the device containing the cable glands.

• Always consult with R. STAHL Schaltgeräte in case of operating conditions which 

deviate from the technical data.

3.3

Modifications and Alterations

4

Function and Device Design

4.1

Function

The wall-mounting socket 8571/11 is an explosion-protected electric equipment. 

It connects portable and stationary electric equipment as well as electric lines and circuits 

in hazardous areas.

It is approved for use in hazardous areas of Zones 1, 2, 21 and 22.

WARNING

Danger due to modifications and alterations to the device! 

Explosion protection is impaired!

• Do not modify or change the device. 

• No liability or warranty for damage resulting from modifications and 

alterations.

WARNING

Danger due to improper use!

Explosion protection is impaired!

• The device may only be used according to the operating conditions 

described in these operating instructions.

• Use the device in hazardous areas only according to these 

operating instructions.

Содержание SolConeX 8571/11 Series

Страница 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages www stahl ex com EN SolConeX Wall Mounted Socket 32 A Series 8571 11...

Страница 2: ...ns 3 2 2 Warning Notes 4 2 3 Symbols on the Device or in the Circuit Diagrams 4 3 Safety Notes 5 3 1 Operating Instructions Storage 5 3 2 Safe Use 5 3 3 Modifications and Alterations 5 4 Function and...

Страница 3: ...601300 Publication Code 2014 01 21 BA00 III en 08 Hardware version n a Software version n a The original instructions are the English edition They are legally binding in all legal affairs 1 3 Further...

Страница 4: ...he danger damage 2 3 Symbols on the Device or in the Circuit Diagrams DANGER Danger for persons Non compliance with the instruction results in severe or fatal injuries to persons WARNING Danger for pe...

Страница 5: ...nstallation and operation observe the information characteristic values and rated operating conditions on the rating and data plates and the information plates located on the device containing the cab...

Страница 6: ...T6 Ta 30 40 C E II 2 G Ex d e ia IIC T5 Ta 30 55 C Certifications and certificates Certificates IECEx ATEX Brazil INMETRO China China Ex India PESO Canada CSA Kazakhstan operating license Korea KCs R...

Страница 7: ...ntacts 2 optional auxiliary contacts ON delayed OFF leading Switching handle lockable in 0 and I position Material Enclosure polyamide glass fibre reinforced Degree of protection IP66 acc to IEC EN 60...

Страница 8: ...h contact sleeve Position clock hour position View front side of the socket Arrangement of socket contacts and terminal markings Arrangement of the socket contacts and terminal markings in the 6h posi...

Страница 9: ...according to IEC 60309 2 1 Mainly for ship installations 2 Frequencies 100 Hz lead to higher heating behaviour This must be compensated by max ambient temperature 40 C temperature class T5 or reductio...

Страница 10: ...nnection chamber upwards Fasten the wall mounting socket by means of four screws in the vertical operating position on an even wall Mounting auxiliary contacts If mounted outdoors equip the enclosure...

Страница 11: ...permissible conductor temperatures are not exceeded When using the core end sleeves attach them using a suitable tool Observe the insulating capacity and separation distances between intrinsically saf...

Страница 12: ...h the clamping plate Check if the conductors are clamped properly Align the conductors the clamping units must not be under tension Tighten the cable gland s Close the enclosure For the tightening tor...

Страница 13: ...l the unused cable entries with plugs certified to Directive 94 9 EC and unused bores with stopping plugs certified to Directive 94 9 EC Use only in completely mounted state 9 Operation Only Type 8571...

Страница 14: ...EC EN 60079 0 whether the device is used according to its designated use 10 2 Maintenance WARNING Unauthorized work being performed on the device Risk of injuries and material damage Work performed on...

Страница 15: ...aning with a damp cloth use water or mild non abrasive non scratching cleaning agents Do not use aggressive detergents or solvents Prevent water and cleaning agents from penetrating the socket contact...

Страница 16: ......

Отзывы: