Safety information 

 

Read the safety information listed in section 8 carefully to avoid injury 
and damage to equipment! 

 

8.1 

General safety information 

  All relevant accident prevention regulations and the rules for electric installations have to 

be  observed  during  installation,  maintenace  and  operations.  All  persons  involved  in 
installation, commission, maintenance and repairs of this device and its accessories must 
be qualified accordingly and must have familiarised themselves with this manual and any 
associated documentation. 

  In case of non-compliance or contravention of the above protection is no longer guaranteed 

and all warranty claims shall be null and void. 

  National safety and accident prevention rules apply. 

  Use the device for its intended purpose only. 

  No changes to the device are permitted. The enclosure may only be opened by R. STAHL 

HMI Systems GmbH. 

  The first four digits of the serial number on the type plate stand for the year of manufacture. 

8.2 

Cautionary note 

 

This is a Class A product. 
In a domestic environment this product may cause radio interference 
in which case the user may be required to take adequate measures. 

 

8.3 

Installation safety information 

  The applicable national assembly and installation rules and the generally accepted technical 

rules must be observed. The device and its accessories must be connected and operated 
according  to  applicable  standards,  directives  and  installation  guidelines.  Only  quali

fied 

personnel  or  personnel  that  has  been  instructed  accordingly  are  allowed  to  install  the 
device.  

  The device has been certified as a fixed, stationary device. The device must be mounted 

on a bracket or be fixed to a specified place in another way. 

  The device may only be moved when it is disconnected from the mains. Keep in mind the 

EPL. 

  Only appropriate tools must be used for the installation. 

  The wire used for earthing must have a minimum cross section of 4 mm² ! Make sure that 

there is equipotential bonding between the devices. 

  We recommend you use screened cables with the device. Routing of the data cable may 

reduce performance.  

  The maximum voltage of 250 V and a short current of 1500 A must not exceed at the place 

of installation. 

 

 

 

CAUTION

 

 

CAUTION

 

Содержание OS-IT-479-2TX

Страница 1: ...vice platform IT xx9 SERIES 400 Panel PC SERIES 500 Thin Clients R STAHL HMI Systems GmbH Adolf Grimme Allee 8 D 50829 Cologne HW Rev IT 4x9 01 00 11 HW Rev IT 5x9 01 00 11 Operating Instructions Vers...

Страница 2: ...written consent of the publisher This document may be subject to change without notice Any warranty claims are limited to the right to demand amendments Liability for any damage that might result from...

Страница 3: ...may result in injury if ignored Information highlighted by this symbol indicates measures for the prevention of damage to machinery or equipment Information highlighted by this symbol indicates impor...

Страница 4: ...eneral safety information 11 8 2 Cautionary note 11 8 3 Installation safety information 11 8 4 Safety information for operation 12 9 Mounting and dismounting 12 9 1 General information 12 10 Commissio...

Страница 5: ...tion system via the external serial interfaces RS 232 Ethernet The USB interfaces also external can be used for the connection of various peripheral devices Furthermore the interfaces for keyboard mou...

Страница 6: ...60 Hz Rated operational power typ 50 W 170 BTU Power consumption AC 1 1 A Fuses AC 4 AT Connections via standard plug Plug version AC IEC plug female Plug version USB USB A connector Further connectio...

Страница 7: ...C the display will need a certain amount of time to warm up until everything is clearly visible Depending on how low the temperature is this process may last up to 3 hours Temperature note general Th...

Страница 8: ...1000 6 4 2007 A1 2011 Interference emission EN 55032 2012 EMC interference emission EN 55024 2010 Interference resistance properties Low voltage directive Directive 2014 35 EU IEC 60950 1 2005 A1 2009...

Страница 9: ...aa bb cc dd ee C0 gg hh ii jj kk ll No internal card reader IT 479 aa bb cc dd ee ff P2 hh ii jj kk ll AMD GX 217GA processor IT 479 aa bb cc dd ee ff gg R3 ii jj kk ll 4 GB RAM IT 479 aa bb cc dd ee...

Страница 10: ...ii jj kk ll No Bluetooth IT 579 aa bb cc dd ee C0 gg hh ii jj kk ll No internal card reader IT 579 aa bb cc dd ee ff P2 hh ii jj kk ll AMD GX 217GA processor IT 579 aa bb cc dd ee ff gg R3 ii jj kk l...

Страница 11: ...and for the year of manufacture 8 2 Cautionary note This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequat...

Страница 12: ...be replaced In general and particularly when opening and closing enclosures users must take care not to get injured by getting caught trapped 9 Mounting and dismounting 9 1 General information Assembl...

Страница 13: ...terface connection type A USB2 0 LAN1 Data 4 1 8 RJ 45 connector Ethernet interface copper connection 1 LAN2 Data 5 1 8 RJ 45 connector Ethernet interface copper connection 2 COM1 serial 6 9 pin sub D...

Страница 14: ...P enclosure 2 P 3 LSP Loudspeaker output optional 4 LSP 5 GND 12 VDC output 1 A 6 12 V DC F 13 for wire L Fuses 2x for wire N max recommended cable length for USB keyboard mouse RS 232 and audio 3 m T...

Страница 15: ...cluded in the delivery to enable you to restore your HMI device to its original state This recovery stick USB drive also optionally available intrinsically safe contains the factory image with which t...

Страница 16: ...I devices the C system drive can be protected from unauthorised writing EWF This is not the case for other Windows operating systems R STAHL HMI Systems GmbH recommends you leave the write protection...

Страница 17: ...We have to ask you not to return a unit if you are unable to completely remove any hazardous substances We shall bill you for any costs arising from insufficiently cleaned units such as disposal or da...

Страница 18: ...Operating Instructions OS IT xx9 Declaration of EC conformity Page 18 of 20 R STAHL HMI Systems GmbH OI_IT_xx9_en_V_01_00_01 docx 19 12 2017 15 Declaration of EC conformity...

Страница 19: ...s all the changes made in every version of the operating instructions Version 01 00 00 Original version of the operating instructions Version 01 00 01 Addition of warning according to Batteries Additi...

Страница 20: ...I Systems GmbH Adolf Grimme Allee 8 D 50829 Cologne Phone switchboard 49 0 221 76 806 1000 hotline 5000 Fax 4100 E mail switchboard office stahl hmi de hotline support stahl hmi de www stahl de www st...

Отзывы: