Operating Instructions OS-IT-xx9 

Technical data 

Page 6 of 20 

 R. STAHL HMI Systems GmbH / OI_IT_xx9_en_V_01_00_01.docx / 19.12.2017 

Technical data 

Function / Equipment 

OS-IT-479-2TX 

OS-IT-579-2TX 

General information 

HMI-type 

Operator station 

Technology 

Panel PC 

Thin Client 

Explosion protection 

Application range (Zones) 

non-Ex (safe area) 

Electrical data 

Processor 

AMD GX-217GA 

Processor details 

AMD GX-217GA 1.65 GHz; Dual Core 

Main memory 

4 GB 

Data memory 

64 GB MLC 

128 GB MLC 

64 GB MLC 

Graphics controller 

AMD Radeon HD 8280E 

Memory technology 

SSD solid state flash drive 

Operating System 

Windows Embedded Standard 7 (64-Bit) 

Windows 7 Ultimate (64-Bit) 

Windows 10 (32-Bit and 64-Bit) 

Windows 10 IoT Enterprise 

Language support 

via Windows operating system 

HMI Image 

Remote Firmware 

Input voltage range 

85 

– 250 VAC 

Nominal voltage range 

100 

– 240 VAC 

Frequency range 

50 - 60 Hz 

Rated operational power 

typ. 50 W (170 BTU) 

Power consumption AC 1 

1 A 

Fuses AC 

4 AT 

Connections 

via standard plug 

Plug version AC 

IEC plug (female) 

Plug version USB 

USB-A connector 

Further connections 

12 VDC Output 

external on / off switch (pre-mounted at enclosure) 

Loudspeaker output (optional) 

Further connections - note 

Only accessories approved by STAHL HMI may be connected to the 12 VDC output. 

Plug version further connections 

pluggable screw terminal, green, 6-pin 2.5 mm² 

Fuses 

2x 4A time-lag, 250 V 

Ethernet / Data 

2x 10/100/1000Base-TX 

Interface medium 

CAT7 Data transmission 

USB interface 

4x USB 

Interface serial 

2x RS-232 

Interface audio 

1 x Audio Line in / out 

Connection impedance 

12 W at 4 Ohm 

Data cable 

CAT7 installation cable AWG 23 

Length of data cable 

max. 100m 

Minimum requirement connection cable 
supply 

3 x 1.5 mm² 

Minimum requirement connection cable 
Ethernet 

CAT6 

Real-time clock 

Yes 

Real-time clock data buffer 

Lithium battery and capacitor buffered, maintenance-free 

Battery type 

B

R2032 

Battery buffer 

> 5 years 

Capacitor buffer 

at least 4 days 

Содержание OS-IT-479-2TX

Страница 1: ...vice platform IT xx9 SERIES 400 Panel PC SERIES 500 Thin Clients R STAHL HMI Systems GmbH Adolf Grimme Allee 8 D 50829 Cologne HW Rev IT 4x9 01 00 11 HW Rev IT 5x9 01 00 11 Operating Instructions Vers...

Страница 2: ...written consent of the publisher This document may be subject to change without notice Any warranty claims are limited to the right to demand amendments Liability for any damage that might result from...

Страница 3: ...may result in injury if ignored Information highlighted by this symbol indicates measures for the prevention of damage to machinery or equipment Information highlighted by this symbol indicates impor...

Страница 4: ...eneral safety information 11 8 2 Cautionary note 11 8 3 Installation safety information 11 8 4 Safety information for operation 12 9 Mounting and dismounting 12 9 1 General information 12 10 Commissio...

Страница 5: ...tion system via the external serial interfaces RS 232 Ethernet The USB interfaces also external can be used for the connection of various peripheral devices Furthermore the interfaces for keyboard mou...

Страница 6: ...60 Hz Rated operational power typ 50 W 170 BTU Power consumption AC 1 1 A Fuses AC 4 AT Connections via standard plug Plug version AC IEC plug female Plug version USB USB A connector Further connectio...

Страница 7: ...C the display will need a certain amount of time to warm up until everything is clearly visible Depending on how low the temperature is this process may last up to 3 hours Temperature note general Th...

Страница 8: ...1000 6 4 2007 A1 2011 Interference emission EN 55032 2012 EMC interference emission EN 55024 2010 Interference resistance properties Low voltage directive Directive 2014 35 EU IEC 60950 1 2005 A1 2009...

Страница 9: ...aa bb cc dd ee C0 gg hh ii jj kk ll No internal card reader IT 479 aa bb cc dd ee ff P2 hh ii jj kk ll AMD GX 217GA processor IT 479 aa bb cc dd ee ff gg R3 ii jj kk ll 4 GB RAM IT 479 aa bb cc dd ee...

Страница 10: ...ii jj kk ll No Bluetooth IT 579 aa bb cc dd ee C0 gg hh ii jj kk ll No internal card reader IT 579 aa bb cc dd ee ff P2 hh ii jj kk ll AMD GX 217GA processor IT 579 aa bb cc dd ee ff gg R3 ii jj kk l...

Страница 11: ...and for the year of manufacture 8 2 Cautionary note This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequat...

Страница 12: ...be replaced In general and particularly when opening and closing enclosures users must take care not to get injured by getting caught trapped 9 Mounting and dismounting 9 1 General information Assembl...

Страница 13: ...terface connection type A USB2 0 LAN1 Data 4 1 8 RJ 45 connector Ethernet interface copper connection 1 LAN2 Data 5 1 8 RJ 45 connector Ethernet interface copper connection 2 COM1 serial 6 9 pin sub D...

Страница 14: ...P enclosure 2 P 3 LSP Loudspeaker output optional 4 LSP 5 GND 12 VDC output 1 A 6 12 V DC F 13 for wire L Fuses 2x for wire N max recommended cable length for USB keyboard mouse RS 232 and audio 3 m T...

Страница 15: ...cluded in the delivery to enable you to restore your HMI device to its original state This recovery stick USB drive also optionally available intrinsically safe contains the factory image with which t...

Страница 16: ...I devices the C system drive can be protected from unauthorised writing EWF This is not the case for other Windows operating systems R STAHL HMI Systems GmbH recommends you leave the write protection...

Страница 17: ...We have to ask you not to return a unit if you are unable to completely remove any hazardous substances We shall bill you for any costs arising from insufficiently cleaned units such as disposal or da...

Страница 18: ...Operating Instructions OS IT xx9 Declaration of EC conformity Page 18 of 20 R STAHL HMI Systems GmbH OI_IT_xx9_en_V_01_00_01 docx 19 12 2017 15 Declaration of EC conformity...

Страница 19: ...s all the changes made in every version of the operating instructions Version 01 00 00 Original version of the operating instructions Version 01 00 01 Addition of warning according to Batteries Additi...

Страница 20: ...I Systems GmbH Adolf Grimme Allee 8 D 50829 Cologne Phone switchboard 49 0 221 76 806 1000 hotline 5000 Fax 4100 E mail switchboard office stahl hmi de hotline support stahl hmi de www stahl de www st...

Отзывы: