background image

Operating Instructions Industrial Box PC 

Safety information 

Page 10 of 24 

 R. STAHL HMI Systems GmbH / OI_Industrial_Box_PC_en_V_01_00_00.docx / 26.09.2018 

Safety information 

 

Read  the  safety  information  listed  in  section  7.1  carefully  to  avoid 
injury and damage to equipment! 

 

7.1 

General safety information 

  For  the  installation  and  operation  of  the  device,  please  note  the  information  on  ambient 

conditions and the chapter headed "Commissioning". 

  When replacing the lithium battery on the mainboard, please follow the instructions in the 

chapter headed "Replacing the lithium battery". 

  Caution: system components may heat up. 

  The activities described in these instructions require special care. 

  Repairs  may  only  be  carried  out  by  authorised, qualified  staff.  Faulty  pairs  may  result  in 

risks to life (electrical shock, energy risk, fire risk) or damage to the device. 

  Operate the device only when it is closed. 

7.1.1 

Power line and power adapter 

  The power line included in the delivery meets the requirements of the country in which you 

have purchased the device. Make sure the power cable is approved for use in the country 
in which you are using it. 

  The power cable of the power adapter must only be connected to a socket if the device is 

connected. 

  Do not use the power adapter with other devices. 

  Only use the power adapter intended for the device. 

  Ensure  that  the  power  consumption  of  the  power  adapter  does  not  exceed  that  of  the 

electric circuit to which it is connected. 

  On/off switches do not isolate the device from the line voltage. For a complete separation 

from the line voltage you need to pull the plug from the socket. 

7.1.2 

Transporting the device 

  Transport all devices individually and only in their original packaging or in a different kind 

of packaging that provides protection against shock and impact. 

  Unpack the devices at the point of installation only. 

  If  the  device  is  brought  in  from  a  cold  environment  to  the  operating  room,  condensation 

might  form.  Before  operating  the  device,  wait  until  it  has  acclimatised  and  is  absolutely 
dry. 

 

 

CAUTION

 

Содержание IBPC-5x1

Страница 1: ...OperatingInstructions Industrial Box PC R STAHL HMI Systems GmbH Adolf Grimme Allee 8 D 50829 Cologne Version 01 00 00 Issue date 26 09 2018...

Страница 2: ...n consent of the publisher The information in this document is subject to change without notice Any warranty claims are limited to the right to demand amendments Liability for any damage that might re...

Страница 3: ...injury if ignored This sign alerts users to hazards that may damage machinery or equipment or result in injury if ignored Information highlighted by this symbol indicates measures for the prevention o...

Страница 4: ...0 7 1 2 Transporting the device 10 7 1 3 Cleaning the device 11 8 Installing the device 11 8 1 Vertical operation 12 8 2 Horizontal operation 13 9 Commissioning 14 9 1 Connections 14 9 1 1 Front 14 9...

Страница 5: ...00 docx 26 09 2018 Page 5 of 24 10 4 Retrieving the BIOS set up 18 11 System modifications 18 11 1 Notes on assemblies 18 11 2 Opening the enclosure 19 11 3 Closing the enclosure 19 11 4 Replacing the...

Страница 6: ...ructions enclosed in this delivery as well as the operating instructions of the additional equipment to be connected 2 Function The type IBPC 5x1 Industrial Box PCs are powerful reliable Thin Clients...

Страница 7: ...B DDR3 1600 Data memory 32 GB Memory technology Flash drive solid state drive SSD MLC Operating system Windows 10 IoT Enterprise 2016 LTSB 64 bit Language support via operating system Image Remote fir...

Страница 8: ...n IEC 60950 1 2005 Am 1 2009 Information technology devices Safety General Requirements RoHS directive 2011 65 EU Classification EN 50581 2012 Technical documentation evaluating electric and electroni...

Страница 9: ...PC 5x1 aa AC cc dd ee ff gg hh ii jj kk ll mm Power supply 100 240 VAC 50 60 Hz IBPC 5x1 aa bb W00 dd ee ff gg hh ii jj kk ll mm no WLAN IBPC 5x1 aa bb cc B0 ee ff gg hh ii jj kk ll mm no Bluetooth IB...

Страница 10: ...dapter The power line included in the delivery meets the requirements of the country in which you have purchased the device Make sure the power cable is approved for use in the country in which you ar...

Страница 11: ...ry substantial risks for the user e g electric shock Make sure that no liquid reaches the inside of the devices Clean the outside of the enclosure with a dry cloth If the device is very dirty you may...

Страница 12: ...symbols indicating the direction in which to slide the foot when mounting dismounting it attach and lock foot into position slide to the left closed lock unlock and detach foot slide to right open loc...

Страница 13: ...enings in the enclosure 1 The feet have lock symbols indicating the direction in which to slide the foot when mounting dismounting it attach and lock foot into position slide to the left closed lock u...

Страница 14: ...onnection Meaning 1 Voltage connector Connection for power supply adapter DC IN 2 Security lock mechanism 3 DVI I connector DVI screen connection 4 Display port Display port 5 9 pin sub D plug male Se...

Страница 15: ...a cable always do so by pulling at the plug Do not pull the cable 9 2 1 Power supply adapter Connect the power line 1 to the power supply adapter Connect the power supply adapter cable 2 to the voltag...

Страница 16: ...tch the Box PC back on 9 2 5 Network LAN Connect the power line to one of the two RJ45 LAN interfaces 9 2 6 USB A great variety of external devices e g printer scanner modem can be connected to the US...

Страница 17: ...ces have already been registered and activated The EOL End of Life date for Windows 10 IoT Enterprise 2016 LTSB for support and updates has been set by Microsoft to 2026 07 31 10 1 1 Recovery If a Box...

Страница 18: ...ke sure you do not trap any cables when installing or removing any components 11 1 Notes on assemblies Be careful with the locking mechanisms detents and centring bolts when you replace assemblies or...

Страница 19: ...sed again Carefully open the enclosure because there are electrical lines from the enclosure lid to the system which may rip Remove any plugged lines that are in the way Remove the screws on the back...

Страница 20: ...The lithium battery must only be replaced with an identical type or one recommended by the manufacturer Do not dispose of the battery as household waste It will be taken back by the manufacturer shop...

Страница 21: ...ctive applies The Box PCs are classified according to the table below old new Directive WEEE I Directive 2002 96 EC WEEE II Directive 2012 19 EU Valid until 2018 08 14 from 2018 08 15 Category 9 Monit...

Страница 22: ...Operating Instructions Industrial Box PC Declaration of EC conformity Page 22 of 24 R STAHL HMI Systems GmbH OI_Industrial_Box_PC_en_V_01_00_00 docx 26 09 2018 13 Declaration of EC conformity...

Страница 23: ...es R STAHL HMI Systems GmbH OI_Industrial_Box_PC_en_V_01_00_00 docx 26 09 2018 Page 23 of 24 14 Release notes The chapter entitled Release Notes contains all the changes made in every version of the O...

Страница 24: ...Systems GmbH Adolf Grimme Allee 8 D 50829 Cologne Phone switchboard 49 0 221 76 806 1000 hotline 5000 Fax 4100 E mail switchboard office stahl hmi de hotline support stahl hmi de www r stahl com www s...

Отзывы: