background image

260520 / 640960300090

2018-11-08·BA00·III·en·02

Mounting and installation  

17

Emergency Luminaire with LED

Series EXLUX 6409/1

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN

8.2

Mounting / dismounting, operating position

15780E00

03257E00

Wall mounting bracket 

fitted in mounting rail

Bracket for wall mounting with 

pipe section

17756E00

Dimen

-

sions

Luminaire
28 W

52 W

L1

1135 [44.69]

1744 [68.66]

L2

390 [15.35]

338 [13.31]

Linear luminaire EXLUX with pole mounting sleeve

DANGER

Explosion hazard due to electrostatic discharge

Non-complicance results in severe or fatal injuries.

Do not use the luminaire in strong charge generating environments!

The following processes/activities should be avoided:

• accidental friction

• particle currents

Dimensional drawings for assembly parts and accessories  

(all dimensions in mm [inches]) - Subject to alterations

186 [7,32]

146 [5,75]

200 [7,87]

80

[3,15]

Ø

42

± 0,60

[

1,65

]

Ø

± 0,02

Содержание EXLUX 6409/1 Series

Страница 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Operating instructions Additional languages www stahl ex com EN Emergency Luminaire with LED Series EXLUX 6409 1...

Страница 2: ...5 3 2 Safe use 5 3 3 Intended Use 5 3 4 Modifications and alterations 5 4 Function and device design 6 4 1 Function 6 4 2 Device design 6 5 Technical data 8 6 Engineering 12 6 1 Mains operation 12 6...

Страница 3: ...eet For further languages see www stahl ex com 1 4 Conformity with standards and regulations See certificates and EU Declaration of Conformity www stahl ex com The device has IECEx approval See IECEx...

Страница 4: ...e and source of danger damage Consequences of danger Taking countermeasures to avoid the danger damage Symbol Meaning Tips and recommendations on the use of the device General danger Danger due to exp...

Страница 5: ...urpose only We cannot be held liable for damage caused by incorrect or unauthorized use or by non compliance with these operating instructions Before installation and commissioning make sure that the...

Страница 6: ...case of power failure switching off the equipment by means of a central lock optional when the luminaire is opened weekly functional test permanently integrated annual rated operating time test 4 2 D...

Страница 7: ...409 1 EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN 18638E00 1 Translucent cover 7 Luminaire enclosure 2 Control gear 8 Battery enclosure 3 Battery 9 Mounting plate top si...

Страница 8: ...ications and certificates Certificates IECEx ATEX Technical Data Electrical data Control gear AC 110 V 240 V 10 50 60 Hz Inrush current Ipeak 62 A t 122 ms maximum number of luminaires per miniature c...

Страница 9: ...temperature K 5 000 5 000 5 700 5 700 without diffuser Luminous flux lm typ 3 100 typ 6 200 typ 3 400 typ 6 800 Luminaire efficacy lm W typ 111 typ 119 typ 121 typ 131 with diffuser Luminous flux lm...

Страница 10: ...nt cover Polycarbonate Seal Silicone foam gasket in the lamp cover Luminaire locking Central locking which can be opened closed using a socket key M8 wrench size 13 hinged lamp cover Mounting Installa...

Страница 11: ...gear is disconnected by means of a switch The battery set can be replaced after disconnecting the plug in contacts Technical Data Through wiring Standard luminaire Luminaires are equipped with interna...

Страница 12: ...N EN EN EN EN EN EN EN EN 6 Engineering 6 1 Mains operation 6 1 1 Stand by operation The light fitting is switched off 6 1 2 Continuous operation The light fitting is switched on 6 1 3 Normal lighting...

Страница 13: ...erminals Remote switch of the control gear 6 2 1 Connection version remote switch The remote switch is directly connected to the control gear The following connection versions are possible Point to po...

Страница 14: ...ry place no condensation and vibration free Do not drop the device 7 2 Batteries Do not transport in explosive dust atmosphere Do not transport together with other materials Handle with care Store pro...

Страница 15: ...affected due to external influences i e pressure conditions chemical mechanical thermal and electric impact such as vibration humidity and corrosion see IEC EN 60079 14 The device must only be install...

Страница 16: ...ssembly parts and accessories all dimensions in mm inches Subject to alterations 15778E00 15779E00 Mounting rail 15782E00 15781E00 15783E00 Ring bolt fitted in insert nut of the luminaire Mounting bra...

Страница 17: ...E00 Dimen sions Luminaire 28 W 52 W L1 1135 44 69 1744 68 66 L2 390 15 35 338 13 31 Linear luminaire EXLUX with pole mounting sleeve DANGER Explosion hazard due to electrostatic discharge Non complica...

Страница 18: ...with upward light emission in outdoor areas is prohibited DANGER Explosion hazard due to inadmissible heating Non compliance results in severe or fatal injuries Avoid external heat sources and or dire...

Страница 19: ...N EN EN EN EN EN EN EN EN EN Pole mounting using pole mounting sleeve Pole mounting using pipe clamps When mounting the luminaire using top rails ensure that the mounting surface is flat Otherwise the...

Страница 20: ...16328E00 Version L4 mm L mm 28 W 320 80 52 W 670 130 For pipe clamp mounting use the solution of R STAHL Schaltger te GmbH with integrated mounting rail providing reliable and stable four point fixing...

Страница 21: ...Version without switch Disconnect the luminaire from the power supply secure it against being switched on again and open the battery box in order to disconnect the battery Version with switch The lum...

Страница 22: ...ver 2 Closing Close the battery cover 2 Tighten the screws 1 cross head H2 firmly 2 Nm 8 3 2 Electrical connections Electrical connection Observe the maximum clamping possibility of the connecting ter...

Страница 23: ...the grid which functions as charging phase for the battery Optional screw terminals Firmly tighten screws tightening torque 2 Nm for unused clamping units 0 7 Nm Connection terminals Through wiring of...

Страница 24: ...ed dust resistance the required type of protection the required temperature resistance the IP degree of protection according to the rating plate the operating instructions of the cable glands and stop...

Страница 25: ...l screws and nuts have been tightened firmly Check whether all the cable entries and stopping plugs have been tightened firmly Check if all conductors have been clamped firmly Check if the line voltag...

Страница 26: ...ol gear 10 2 Functional and rated operating time test To carry out the test the following prerequisites must be fulfilled the time interval has expired the power supply operation was active for at lea...

Страница 27: ...ire during emergency light mode is repeated after 14 days if rated operating time test is faulty 10 3 Indications When connecting to the power supply Initialisation within 10 seconds After that the LE...

Страница 28: ...ady for operation Blinking green Luminaire is ready for operation Function and rated operating time test activated Red Error Battery is defective or electric circuit is interrupted Blinking red Error...

Страница 29: ...y be carried out by appropriately authorized and qualified electricians Observe the relevant national regulations in the country of use Check Measures the permissible ambient temperature If exceeding...

Страница 30: ...nslucent cover to detach it from the hinge Insert new translucent cover into the hinge All hinges must engage properly Close the luminaire Observe safety notes DANGER Explosion hazard due to explosive...

Страница 31: ...nd store it in the battery case Close the battery case and ensure that the conductors do not get jammed Tighten the screws 1 cross head H2 firmly 2 Nm Resetting the error indication blinking red after...

Страница 32: ...damp cloth Use water or mild cleaning agents Do not use abrasive scratching and aggressive detergents or solvents Never clean the device with a strong water jet e g using a high pressure washer Cause...

Страница 33: ...ending it for recycling Ensure environmentally friendly disposal of all components according to the statutory regulations 13 Accessories and Spare parts CAUTION Danger due to chemical reactions Human...

Страница 34: ......

Отзывы: