background image

2    

       

Content 

 
1

 

Safety instructions ....................................................................................................... 3

 

2

 

Conformity to standards .............................................................................................. 3

 

3

 

Function ...................................................................................................................... 4

 

4

 

Marking and technical data ......................................................................................... 4

 

5

 

Engineering ................................................................................................................. 5

 

5.1

 

Max. ambient temperatures .................................................................................. 5

 

5.2

 

Power dissipation ................................................................................................. 5

 

5.3

 

Engineering of the power dissipation in cabinets .................................................. 6

 

6

 

Arrangement and fitting ............................................................................................... 7

 

6.1

 

Dimensions .......................................................................................................... 7

 

6.2

 

Installation............................................................................................................ 7

 

6.3

 

Mounting and dismounting ................................................................................... 7

 

7

 

Commissioning ........................................................................................................... 8

 

7.1

 

Connections ......................................................................................................... 8

 

7.2

 

Engineering .......................................................................................................... 8

 

7.3

 

Settings ................................................................................................................ 9

 

8

 

Operation and operational states ................................................................................ 9

 

9

 

Maintenance and repair ............................................................................................ 10

 

10

 

Accessories and spare parts .................................................................................. 10

 

 
 

EC-Declaration of Conformity ........................................................................................... 11

 

EC-Type Examination Certificate ..................................................................................... 12

 

 

 

Содержание 9170/12-12-13

Страница 1: ...Type 9170 Switching Repeater 1 1 1 Operating Instructions Type 9170 2 Switching Repeater...

Страница 2: ...Engineering of the power dissipation in cabinets 6 6 Arrangement and fitting 7 6 1 Dimensions 7 6 2 Installation 7 6 3 Mounting and dismounting 7 7 Commissioning 8 7 1 Connections 8 7 2 Engineering 8...

Страница 3: ...lly recognised technical regulations Safety guidelines in these operating instructions Any damage can compromise and even neutralise the explosion protection The following requirements apply if used i...

Страница 4: ...ternal capacitance Ci Internal inductance Li Max connectable capacitance Co IIC IIB I Max connectable inductance Lo IIC IIB I Insulation voltage Um 9 6 V 9 6 V 10 mA 20 mA 24 mW 48 mW 2 42 nF 4 84 nF...

Страница 5: ...F 149 F 9170 22 12 23 131 F 149 F Ventilation With ventilation Installation Single unit DIN rail Orientation any vertical horizontal Channels Type 1 9170 12 12 13 158 F 158 F 158 F 9170 12 12 23 158...

Страница 6: ...e lower and upper ends of the cabinet the air flow path must be kept free from obstacles Result Depending on the engineering the improvement can reach a two times higher power dissipation as with a c...

Страница 7: ...napping onto the pac Bus Note In order to prevent pole reversal during installation the pac Bus elements have been equipped with a keyed connection plug see photo The module is fitted with a matching...

Страница 8: ...t identification volt free contacts at the input Open circuit identification 22 k or 33 k in parallel Short circuit identification 2 7 k in series The loading has to carry out in direct proximity of t...

Страница 9: ...ized Electronic output activated Relay not energized Electronic output deactivated Line fault detection LF activated Open circuit IE 0 05 0 35mA Relay not energized Electronic output deactivated Relay...

Страница 10: ...neration of High Level is missing The High Level can be generated if an resistor is connected externally to the supply voltage e g 5V Self test In order to check basic functions of the device you may...

Страница 11: ...11 EC Declaration of Conformity...

Страница 12: ...12 EC Type Examination Certificate...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...R STAHL Schaltger te GmbH Am Bahnhof 30 74638 Waldenburg W rtt Germany www stahl de ID Nr 9170611310 S BA 9170 2 001 en 06 2009...

Отзывы: