INSTALLATION AND USER MANUAL
200TDHW
8
V0REV1EN0218
-
Distances to 200TDHW:
The maximum allowed distance from the panel to the 200TDHW is 12 meters.
In the picture below is shown the dimensions of the panel:
5.2.
Anchoring panel
Beside the panel, it is supplied a bag with anchoring elements that contains the following pieces:
-
6 x Aluminium support (L shape)
-
6 x Screws M5
-
12 x Nuts M5
-
18 x Washer 5
-
18 x Sheet Metal Screws
-
18 x Blocks M6
Anchor the panels using the lateral and front holes to the suitable surface.
1700
800
1700
800
1700
800
1700
800
1700
800
If the panel is installed at
horizontal position, refrigerant
inlet pipe should be connected
into the bottom connection.
When the panel is installed in
vertical position, always the inlet
and outlet connection has been
at the bottom. (It is not allow to
install the reverse)