![Stafor COMBI 200TDHW Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/stafor/combi-200tdhw/combi-200tdhw_installation-and-user-manual_1357178006.webp)
INSTALLATION AND USER MANUAL
200TDHW
6
V0REV1EN0218
3.1.
Technical data
4.
INSTALLATION STEPS
Before starting the installation, check the availability of all the necessary components and tools:
-
High and low pressure manometers
-
Vacuum pump
-
Scales
-
Nitrogen bottle
-
Refrigerant quality copper pipe
-
Pipe-cutter
-
Tube bender
Cylinder
200DHW
Capacity, L
200
Maximum operating pressure, bar
6
Heat pump data
Energy Efficiency Class
A
Load profile
L
Heating capacity range *, W
1430-2560
Input power range *, W
450-540
Maximum temp. HP, ºC
60
Maximum temp. electric element, ºC
62
Coolant
R134A
Electric data
Power supply, V/ph/Hz
230/1/50
Electric element power, W
1500
Maximum current, A
10,1
Maximum power absorbed, W
2100
Thermodynamic panel
Number of panels
1
Dimensions, mm
1700x800
Maximum operating pressure, bar
10
Refrigerant inlet/ outlet, inch
3/8 - 3/8