Page
ST315B User Handbook
14
Adjusting While Firing
Firing values can be adjusted while the ST315B is firing. Also there are
program pause/un
-
pause and segment advance features that are particular-
ly useful for glass work.
Adjusting Firing Values
While firing operate the
key to select the required parameter as shown by
a flashing lamp on the mimic display. The firing value is shown on the main
display and can now be adjusted with the
&
keys in the usual way. The
contents of the current segment or any segment still to be executed can be
changed. Firing will still carry on as normal while these changes are being
made. The ST315B will return to its normal running display 10 seconds
after key presses cease (or immediately after
is displayed).
Changes made to programs in this way are stored and are used for
subsequent firings.
Segment Advance Facility
While firing press and hold down the
key for about 4 seconds. The
ST315B will sound a short beep and the executing program will immedi-
ately advance one step as indicated by lamps on the mimic panel. The
effect of this is as follows:
-
If a start delay is currently executing then the ST315B will terminate this
and start firing immediately.
If ramping is currently executing then the ST315B will switch to soak at
the current kiln temperature.
If currently soaking then the ST315B will advance to the next segment if
any, or else it will end the firing.
Changes made to the operation of the ST315B in this way are temporary
and are not stored.
Ad
just
ing
Whil
e Firing