background image

5

INSTALLATION 

Installation of filter should only be done by qualified, licensed personnel. For assem-
bly and filling instructions, see pages 6 and 7.

Filter mount must:

• Provide weather and freezing protection.

• Provide space and lighting for easy access for routine maintenance. (See Figure I

and Table 1, Page 4, for space requirements.)

• Be on a reasonably level surface and provide adequate drainage.

• Be as close to pool as possible to reduce line loss from pipe friction.

Piping:

• Piping must conform to local/state plumbing and sanitary codes.

• Use pipe joint sealing compound or Teflon tape on all male  connections of metal

pipe and fittings (except unions). Use Teflon tape or Plasto-Joint Stik

®

on all male

connections of plastic pipe and fittings. DO NOT use pipe dope on plastic pipe; it
will cause stress cracking of the pipe. Do not use sealant or tape on unions – as-
semble them dry and hand tight.

• Do not damage union sealing surfaces and O-Rings.

• Support pipe independently to prevent strains on filter or valve.

• Use 2” pipe to reduce pressure losses as much as possible.

NOTICE: Filter may be located away from pool, but for adequate flow larger pipe
may be needed. For more information about hydraulic design, call 
Sta-Rite Customer Service.

• Fittings restrict flow; for best efficiency use fewest possible fittings.

• Keep piping tight and free of leaks: pump suction line leaks may cause trapped air

in filter tank or loss of prime at pump; pump  discharge line leaks may show up as
dampness or jets of water.

• NOTICE: Overtightening can crack filter ports.

Valves:

• A check valve installed ahead of filter inlet will prevent contaminants from draining

back into pool.

• A check valve installed between filter and heater will prevent hot water from back-

ing up into filter and deforming internal components.

• Install Sta-Rite Two Position Slide Valve or Multiport Selector Valve with filter. See

Table lll.

• Filter ports and valve ports are furnished with union connections.

DO NOT use pipe sealants on union collar (nut).

• Use care before assembly not to damage union sealing surfaces or O-Ring.

Wastewater:

• Be sure all provisions for waste water disposal meet applicable local, state or na-

tional codes. 100 gallons (379 liters) or more of pool water will be discharged dur-
ing filter backwashing. Do not discharge where water will cause flooding or
damage.

Assembly:

See Pages 6 and 7 for assembly filling instructions.

Port

Part

Size

Number

Multi-port

2"

18202-0200

1-1/2"

18202-0150

Brass Slide

2"

WC212-136D

Plastic Slide

2"

WC212-134P

TABLE III - Sta-Rite valves
for use with filters

NOTICE: Use of
valves other than
those listed above
could cause      re-
versed water flow
through filters and
damage to internal fil-
ter components.

Plasto-Joint Stik® is a registered trademark of La-Co Industries, Inc. 

Содержание System 3

Страница 1: ...aimers System 3 Sta Rite and Pentair Water Pool and Spa are trademarks and or registered trademarks of Pentair Water Pool and Spa Inc and or its affiliated companies in the United States and or other counties Unless noted names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair ...

Страница 2: ...W SAFETY IN STRUCTIONS This is the safety alert symbol When you see this symbol on your valve or in this manual look for one of the following signal words and be alert to the po tential for personal injury DANGER warns about hazards that will cause serious personal injury death or major property damage if ignored WARNING warns about hazards that can cause serious personal injury death or major pro...

Страница 3: ...r in system before testing Tighten Sta Rite pump trap lids to 30 ft lbs 4 1 kg cm torque for testing Water pressure for test must be less than 25 PSI 172 kPa Water temperature for test must be less than 100 F 38 C Limit test to 24 hours After test visually check system to be sure it is ready for operation Remove pump trap lid and retighten hand tight only NOTICE These parameters apply to Sta Rite ...

Страница 4: ...008 liters 40 800 Gal 154 428 liters Qty of Media Required Cu Ft 2 56 540cm3 3 84 960cm3 Weight Pounds 200 90 7 kg 300 136 kg Freeboard is the open space between the top of the sand bed and the tank backwash outlet NOTICE 1 cubic foot 28 320 cm3 of sand weighs approximately 100 lbs 45 4kg DO NOT use a finer grade of sand than recommended RECOMMENDED SAND GRADES Use only 20 Silica Sand Size Range 4...

Страница 5: ...fewest possible fittings Keep piping tight and free of leaks pump suction line leaks may cause trapped air in filter tank or loss of prime at pump pump discharge line leaks may show up as dampness or jets of water NOTICE Overtightening can crack filter ports Valves A check valve installed ahead of filter inlet will prevent contaminants from draining back into pool A check valve installed between f...

Страница 6: ...inside and check internal assembly Key No 8 Page 10 for broken or loose laterals Key No 8A Page 10 caused by shipping damage Replace if necessary 3 To eliminate stress on laterals Key No 8A fill tank half full of water be fore loading sand 4 When full top of sand bed should be about 12 1 2 31 75 cm below top of distributor about 1 1 2 3 8 cm below tank flange see Figure 2 5 Wash all sand and dirt ...

Страница 7: ...lter in service Startup Slide Valve 1 With pump OFF raise handle to fully extended position 2 Open air release valve Key No 1 Page 10 3 Start pump circulating water backwards through filter to waste 4 Close air release valve when a steady stream of water is expelled 5 Run pump five minutes or until waste water is clear this purges excess fine particles from system 6 Stop pump lower handle complete...

Страница 8: ...ds through filter to waste 4 Close air release valve when a steady stream of water is expelled 5 Backwash until water runs clear 6 Stop pump lower handle completely to FILTER position and pin in place 7 Filter is now ready for service 8 Open air release valve and release ALL pressure from tank and system 9 Follow Run filter procedure above to restart system MAINTENANCE General Wash outside of filt...

Страница 9: ...ut of tank Figure 6 5 Twist lock new laterals into hub on new internal assembly Figure 7 6 Remove old O Rings on tank fittings Key Nos 19 and 20 and install new O Rings provided Be sure sealing area is clean 7 Drop new internal assembly into tank and secure with tank fittings Key Nos 19 and 20 Figure 8 8 To refill reassemble and restart filter follow instructions in owner s manual To avoid severe ...

Страница 10: ...10 2859 0597 19 19a 20 13 12 14 15 12 16 8 9 10 11 7 0 5 1 0 1 5 2 0 25 30 3 5 4 0 4 5 5 0 5 5 6 0 3 2 1 4 5 6 17 18 21 22 16 ...

Страница 11: ...n Fitting 1 24900 0505 24900 0505 15 1 1 2 NPT Plug 1 27001 0022S 27001 0022S 16 O Ring 2 35505 1425 35505 1425 17 Tank Fitting 1 24900 0500 24900 0500 18 Tank Fitting 1 24900 0501 24900 0501 19 Clamp Assembly 24850 0200 24850 0200 19A Clamp Bolt 24850 0010 24850 0010 20 Tank Lower Half 1 24850 0102S 24851 0103S 21 Cord Ring 1 24850 0008 24850 0009 22 Valve and Gauge Assembly Includes Key Nos 1 5 ...

Страница 12: ... too large consult dealer for recom mendation 3 Low Flow Low Pressure A Pump too small consult dealer for recommendations B Plugged pump plugged line or plugged hair and lint trap clean thoroughly 4 Pool Water Not Clear A Water is chemically out of balance consult pool professional B Inadequate turnover rate consult dealer about equipment sizing C Sand in pool means broken lateral To avoid severe ...

Страница 13: ...13 Blank Page ...

Страница 14: ...14 Blank Page ...

Страница 15: ...Blank Page ...

Страница 16: ...S282 Rev A ...

Отзывы: