Incorrectly installed or tested equipment may fail, causing se-
vere injury or property damage. Read and follow instructions
in owner's manual when installing and operating equipment.
Have a trained pool professional perform all pressure tests.
1. Do not connect system to a high pressure or city water system.
2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE all air is out of
system before operating or testing equipment.
Before pressure testing, make the following safety checks:
• Check all clamps, bolts, lids, and system accessories before testing.
• Release all air in system before testing.
• Tighten Sta-Rite pump trap lids to 30 ft. lbs. (4.1 kg-cm) torque for testing.
• Water pressure for test must be less than 25 PSI (172 kPa).
• Water temperature for test must be less than 100˚ F. (38˚ C).
• Limit test to 24 hours. After test, visually check system to be sure it is
ready for operation. Remove pump trap lid and retighten hand tight only.
NOTICE: These parameters apply to Sta-Rite equipment only. For non
Sta-Rite equipment, consult manufacturer.
If filter clamp is
adjusted under pres-
sure, tank will blow
off of base, causing
severe injury or major
property damage.
BEFORE WORKING
ON FILTER:
1. Stop pump.
2. Open air release
valve.
3. Release all pressure
from system.
Filter pumps require
hazardous voltage
which can shock,
burn, or cause death
BEFORE WORKING
ON PUMP OR MOTOR
Disconnect power to
motor.