background image

19

 

MAINTENANCE 

Pump Strainer Basket

The pump strainer basket (or ‘strainer pot’, ‘hair and lint 

pot’), is located in front of the volute. Inside the chamber 

is the basket which must be kept clean of leaves and 

debris at all times. View basket through the ‘See Through 

Lid’ to inspect for leaves and debris. 
Regardless of the length of time between filter cleaning, 

it is most important to visually inspect the basket at least 

once a week. A dirty basket will reduce the efficiency of 

the filter and heater and also put an abnormal stress on 

the pump motor which would result in a costly repair bill. 

DO NOT open the strainer pot if SuperFlo

® 

VS Variable Speed Pump fails to prime or if pump has been operating without water in 

the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding 
hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the 
suction and discharge valves are open and strainer pot temperature is cool to touch, then open with extreme caution.
To prevent damage to the pump and for proper operation of the system, clean pump strainer and skimmer baskets regularly.

Cleaning the Pump Strainer Basket

1.  Turn off the pump at the circuit breaker.
2.  Relieve pressure in the system by allowing the water to 

cool. 

3.  Gently tap the clamp in a counter-clockwise direction to 

remove the clamp and lid.

4.  Remove debris and rinse out the basket. Replace the 

basket if it is cracked.

5.  Put the basket back into the housing.

 

Be sure to align the 

notch in the bottom of the basket with the rib in the bottom 

of the volute.

6.  Fill the pump pot and volute up to the inlet port with water.
7.  Clean the cover, O-ring, and sealing surface of the pump 

pot.  Note: It is important to keep the lid O-ring clean and 

well lubricated.

8.  Reinstall the lid by placing the lid on the pot. Be sure the 

lid O-ring is properly placed.  Seat the clamp and lid on the 

pump then turn clockwise until the handles are horizontal.

9.     Turn the power “ON” at the house circuit breaker. Reset 

the pool time clock to the correct time, if applicable. 

10.   Open the High Flow

 manual air relief valve on top of the 

filter.

11.   Stand clear of the filter. Start the pump.
12.   Bleed air from the filter until a steady stream of water 

comes out. Close the High Flow

 Manual Air Relief Valve.

THIS SYSTEM OPERATES UNDER HIGH PRESSURE. 

When any part of the circulating system (e.g., 

Lock Ring, Pump, Filter, Valves, etc.) is serviced, 

air can enter the system and become pressurized. 

Pressurized air can cause the lid to separate which 

can result in serious injury, death, or property 

damage. To avoid this potential hazard, follow 

above instructions.

Strainer Pot Assembly

Winterizing

You are responsible for determining when freezing 

conditions may occur. If freezing conditions are 

expected, take the following steps to reduce the risk of 

freeze damage. Freeze damage is not covered under 

warranty. 
To prevent freeze damage, follow the procedures below:
1.  Shut off electrical power for the pump at the circuit 

breaker.

2.  Drain the water out of the pump housing by 

removing the two thumb-twist drain plugs from the 

housing. Store the plugs in the pump basket.

3.  Cover the motor to protect it from severe rain, snow 

and ice.

CLAMP

LID

O-RING

BASKET

VOLUTE

Note:  Do not wrap motor with plastic or other air tight 

materials during winter storage. The motor may be 

covered during a storm, winter storage, etc., but never 

when operating or expecting operation.
Note:  In mild climate areas, when temporary freezing 

conditions may occur, run your filtering equipment all 

night to prevent freezing. 

English 

Содержание S5P1R-VS

Страница 1: ...NG BEDIENUNGSANLEITUNG GUIDE DE L INSTALLATION GUIA DE INSTALACION GUIDE ALL INSTALLAZIONE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WATER SOLUTIONS P INSB...

Страница 2: ...and Functions Quick Start Guide Factory Default Schedule User Defined Schedule Control Panel Overview Navigation Operating the Pump Keypad Overview Setting a Schedule Schedule Tables Pump Operation f...

Страница 3: ...THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAIN AND AWAY FROM ALL SUCTION OUTLETS F THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG...

Страница 4: ...pecific application and properly installed Fitting a non return valve after the pump on the installation will prevent the impeller from unwinding and is strongly recommended Pumps improperly sized or...

Страница 5: ...40 years Compact rugged and easy to maintain the SuperFlo VS pump will deliver years of reliable service SuperFlo VS Pump PUMP OVERVIEW Pump Controller Features Simple user interface Motor design red...

Страница 6: ...ine the most satisfactory settings as dictated by the conditions In most cases setting the pump at the lowest speed for the longest duration is the best strategy to minimize energy consumption However...

Страница 7: ...view X Power START FAULT STEP1 STEP2 STEP3 OVERRIDE SETTING SETTING BARGRAPH X Step1 X X X Step2 X X X Step3 X X X Override X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X LED Indi...

Страница 8: ...P 1 key again to change the SPEED setting The SPEED setting LED will illuminate The bar graph will show default SPEED for STEP 1 see figure 2 3 Press UP or DOWN arrows to change the SPEED 4 Press any...

Страница 9: ...he pump is capable of operating Pressing the stop button will turn off the START LED and stop the motor if running If power is connected to the SuperFlo VSVariable Speed Pump motor pressing any of the...

Страница 10: ...er to program an overlap between different STEPs of the schedule The STEP currently being set will always take priority over any previous settings In the event a user attempts to program with a combin...

Страница 11: ...finitely until the user presses the STOP key Note Pressing a STEP key other than for the STEP currently running will cause an immediate transition to the newly selected STEP The pump will continue wit...

Страница 12: ...der to change the OVERRIDE settings if the duration is set to 0 HRS Schedule Advance The Schedule Advance mode allows the user to press the START button at one time of the day with the 24 hour schedul...

Страница 13: ...r more than three 3 seconds The START and OVERRIDE buttons will blink once every second indicating that the time out feature is enabled These LEDs will stop blinking once this feature is cancelled Tem...

Страница 14: ...d to factory defaults Priming The pump will always run the PRIMING sequence when starting from the OFF state except when starting in OVERRIDE The factory Prime settings are 2850 RPM for three 3 minute...

Страница 15: ...National Electrical Code and all applicable local codes and ordinances When in doubt use a heavier gauge larger diameter wire Heavier gauge will allow the motor to run cooler and more efficient 4 Be s...

Страница 16: ...35 mm and will handle any commonly available mating connectors For a direct wire connection the wire insulation should be stripped to a length of approximately 8 mm The terminal block is capable of h...

Страница 17: ...g this area External Supply Range 18 30V AC 24V AC 20 9 30V DC 12 24V DC 20 Figure 6 Wiring Diagram for Automation Control System Inputs UI DIGITAL INPUT CONNECTOR J202 STEP 1 pin 1 STEP 2 pin 2 STEP...

Страница 18: ...oncept can be applied to a solar system or any other type of control system Note There is no schedule for automation system inputs The timing for each speed is controlled directly by the inputs Note T...

Страница 19: ...of the pump pot Note It is important to keep the lid O ring clean and well lubricated 8 Reinstall the lid by placing the lid on the pot Be sure the lid O ring is properly placed Seat the clamp and lid...

Страница 20: ...Inordertoavoidthepossibilityofpersonalinjury makesurethesuctionanddischargevalvesare open and strainer pot temperature is cool to touch then open with extreme caution Besurenottoscratchormarthepolishe...

Страница 21: ...valve close the valve The system should now be free of air and recirculating water to and from the pool Pump Reassembly 1 When installing the replacement seal into the seal plate use soapy water to we...

Страница 22: ...ot drawing air Turn off electrical power to the pump Disassemble see page 20 Pump Disassembly Clean debris from impeller If debris cannot be removed complete the following steps 1 Remove left hand thr...

Страница 23: ...oblem Possible Cause Corrective Action Pump runs without flow Impeller is loose Air leak Clogged or restricted plumbing Check that pump is spinning by looking at fan on back of SuperFloVS Variable Spe...

Страница 24: ...r is running then the FAULT LED will illuminate During the FAULT condition the bar graph LEDs on the interface will turn OFF However the power LED start LED active STEP LED will remain illuminated 3 W...