background image

12

 

Override

The SuperFlo

® 

VS Variable Speed Pump is equipped 

with an OVERRIDE feature, which can be engaged 

to temporarily run at higher or lower speeds ranging 

between 600 to 3450 RPM.  Once the OVERRIDE 

duration has elapsed, the pump will automatically return 

to the programmed schedule.

1.  Pressing the OVERRIDE key while the pump is 

running will cause the pump to start running in the 

OVERRIDE mode at the programmed DURATION 

and SPEED.  The “active LED” for OVERRIDE will 

illuminate.  The DURATION and SPEED setting 

LEDs along with its respective bar graph LED will 

blink back and forth at three (3) second intervals.

2.  The UP (+) / DOWN (-) arrows allow the user to 

configure OVER RIDE DURATION and SPEED. 

These settings can be changed while the pump is 

running. These settings are stored each time the 

UP (+) / DOWN (-) arrows are pressed.

Note: When the OVERRIDE duration ends, the 

pump resumes the 24 hour schedule at the point 

in the currently programmed 24 hour schedule 

where it normally would be running at that time.  

The OVERRIDE duration will not affect the start or 

stop times of the 24 hour schedule. For example, if 

OVERRIDE runs during a period overlapping with a 

later part of STEP 1 and an early part of STEP 2, the 

start time of STEP 3 is not affected.

Note: Pressing/Holding OVERRIDE key for more than 

three (3) seconds will cancel OVERRIDE mode. 

Note: During the OVERRIDE mode, the pump will not 
start with the priming sequence.

Note: It is recommended that you do not set the 
OVERRIDE duration to 0 HRS. Setting the OVERRIDE 

duration to 0 HRS will not allow you to change the 

duration setting while the motor is running. The 

motor will have to be stopped in order to change the 

OVERRIDE settings if the duration is set to 0 HRS. 

Schedule Advance

The Schedule Advance mode allows the user to 

press the START button at one time of the day, 

with the 24-hour schedule starting at a different 

time of day.  The pump can run in the Schedule 

Advance mode (by using the OVERRIDE button) 

and upon completion will begin the programmed 24 

hour schedule at STEP 1 DURATION and SPEED. 
The following steps should be followed to set 
Schedule Advance mode:

Note:

 The OVERRIDE 

button will still function when 

the Schedule Advance mode 

is active.  This will allow the 

user to run the pump during 

the period of the Schedule 

Advance mode.

Note:

 While the pump is 

in the Schedule Advance 

mode, if a user presses 

STEP 1, STEP 2, STEP 3 or 

the START key, the system 

will start the normal schedule and the Schedule Advance 

mode will be canceled.

Note:

 While the pump is in the Schedule Advance mode, 

if a user presses the STOP key, then the Schedule 
Advance mode is canceled.

Note

: If power is lost while the pump is in the Schedule 

Advance mode, then the 24-hour schedule will 
automatically start when power is restored.

1.  With the pump stopped, press and hold 

the START key for more than three (3) 

seconds. The START LED will blink at a rate 

of one second per pulse.  The DURATION 

setting LED and respective bar graph LED 

will remain turned ON until the Schedule 

Advance mode is complete.

2.  Press the UP (+) or DOWN (-) arrows to set 

the desired delay time after which the 24-

hour schedule should start.  The Schedule  

Advance mode will automatically start after 

the desired delay time is selected.  The 

Schedule Advance mode can be cancelled 

by pressing the STOP key. 

Do not perform any maintenance on the motor while the motor is in 
Schedule Advance Mode. The motor may start without warning. This 

event could cause death or serious personal injury.

English          

Содержание S5P1R-VS

Страница 1: ...NG BEDIENUNGSANLEITUNG GUIDE DE L INSTALLATION GUIA DE INSTALACION GUIDE ALL INSTALLAZIONE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WATER SOLUTIONS P INSB...

Страница 2: ...and Functions Quick Start Guide Factory Default Schedule User Defined Schedule Control Panel Overview Navigation Operating the Pump Keypad Overview Setting a Schedule Schedule Tables Pump Operation f...

Страница 3: ...THE OWNER S MANUAL MUST BE LEFT WITH THE POOL OWNER SUCTION ENTRAPMENT HAZARD STAY OFF THE MAIN DRAIN AND AWAY FROM ALL SUCTION OUTLETS F THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG...

Страница 4: ...pecific application and properly installed Fitting a non return valve after the pump on the installation will prevent the impeller from unwinding and is strongly recommended Pumps improperly sized or...

Страница 5: ...40 years Compact rugged and easy to maintain the SuperFlo VS pump will deliver years of reliable service SuperFlo VS Pump PUMP OVERVIEW Pump Controller Features Simple user interface Motor design red...

Страница 6: ...ine the most satisfactory settings as dictated by the conditions In most cases setting the pump at the lowest speed for the longest duration is the best strategy to minimize energy consumption However...

Страница 7: ...view X Power START FAULT STEP1 STEP2 STEP3 OVERRIDE SETTING SETTING BARGRAPH X Step1 X X X Step2 X X X Step3 X X X Override X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X LED Indi...

Страница 8: ...P 1 key again to change the SPEED setting The SPEED setting LED will illuminate The bar graph will show default SPEED for STEP 1 see figure 2 3 Press UP or DOWN arrows to change the SPEED 4 Press any...

Страница 9: ...he pump is capable of operating Pressing the stop button will turn off the START LED and stop the motor if running If power is connected to the SuperFlo VSVariable Speed Pump motor pressing any of the...

Страница 10: ...er to program an overlap between different STEPs of the schedule The STEP currently being set will always take priority over any previous settings In the event a user attempts to program with a combin...

Страница 11: ...finitely until the user presses the STOP key Note Pressing a STEP key other than for the STEP currently running will cause an immediate transition to the newly selected STEP The pump will continue wit...

Страница 12: ...der to change the OVERRIDE settings if the duration is set to 0 HRS Schedule Advance The Schedule Advance mode allows the user to press the START button at one time of the day with the 24 hour schedul...

Страница 13: ...r more than three 3 seconds The START and OVERRIDE buttons will blink once every second indicating that the time out feature is enabled These LEDs will stop blinking once this feature is cancelled Tem...

Страница 14: ...d to factory defaults Priming The pump will always run the PRIMING sequence when starting from the OFF state except when starting in OVERRIDE The factory Prime settings are 2850 RPM for three 3 minute...

Страница 15: ...National Electrical Code and all applicable local codes and ordinances When in doubt use a heavier gauge larger diameter wire Heavier gauge will allow the motor to run cooler and more efficient 4 Be s...

Страница 16: ...35 mm and will handle any commonly available mating connectors For a direct wire connection the wire insulation should be stripped to a length of approximately 8 mm The terminal block is capable of h...

Страница 17: ...g this area External Supply Range 18 30V AC 24V AC 20 9 30V DC 12 24V DC 20 Figure 6 Wiring Diagram for Automation Control System Inputs UI DIGITAL INPUT CONNECTOR J202 STEP 1 pin 1 STEP 2 pin 2 STEP...

Страница 18: ...oncept can be applied to a solar system or any other type of control system Note There is no schedule for automation system inputs The timing for each speed is controlled directly by the inputs Note T...

Страница 19: ...of the pump pot Note It is important to keep the lid O ring clean and well lubricated 8 Reinstall the lid by placing the lid on the pot Be sure the lid O ring is properly placed Seat the clamp and lid...

Страница 20: ...Inordertoavoidthepossibilityofpersonalinjury makesurethesuctionanddischargevalvesare open and strainer pot temperature is cool to touch then open with extreme caution Besurenottoscratchormarthepolishe...

Страница 21: ...valve close the valve The system should now be free of air and recirculating water to and from the pool Pump Reassembly 1 When installing the replacement seal into the seal plate use soapy water to we...

Страница 22: ...ot drawing air Turn off electrical power to the pump Disassemble see page 20 Pump Disassembly Clean debris from impeller If debris cannot be removed complete the following steps 1 Remove left hand thr...

Страница 23: ...oblem Possible Cause Corrective Action Pump runs without flow Impeller is loose Air leak Clogged or restricted plumbing Check that pump is spinning by looking at fan on back of SuperFloVS Variable Spe...

Страница 24: ...r is running then the FAULT LED will illuminate During the FAULT condition the bar graph LEDs on the interface will turn OFF However the power LED start LED active STEP LED will remain illuminated 3 W...

Отзывы: