Performance / Installation

3

PERFORMANCE

GPH (LITERS) AT DISCHARGE FT. OF HEAD

Model

5 (1.5m)

10 (3m)

15 (4.6m)

20 (6.1m)

S44018T

3900(14,763) 2550(9,653)

960(3,634)

0

INSTALLATION

NOTICE:

Install pump on a hard, level surface (cement, asphalt, etc.). Never place

pump directly on earth, clay or gravel surfaces.

Piping – Effluent Applications (3/4" or Less Solids)

Piping must be 1-1/2" minimum to carry volume of pump discharge. Check local
codes to determine if a check valve is required in your system. In cold climates,
check valves are not used to prevent effluent from freezing in piping.

If using as a sump pump, a check valve is recommended.

Piping – Sewage Applications (2" or Less Solids)

In any case, piping must not be smaller than pump discharge.

When installed in a sewage system, pipe must be capable of handling semi-solids of
at least 2" (5.1 cm) diameter.

The rate of flow in the discharge pipe must keep any solids present in suspension in
the fluid. To meet minimum flow requirements (2 feet (.6 m) per second in discharge
line), size pipe as follows:

A Pipe Size Of:

Will Handle a Flow Rate Of:

1-1/2" (3.8 cm)

12 GPM (45 LPM)

2" (5.1 cm)

21 GPM (79 LPM)

2-1/2" (6.3 cm)

30 GPM (113 LPM)

3" (7.6 cm)

48 GPM (181 LPM)

Use a 2" (5.1 cm) swing check valve in pump discharge to prevent backflow of liquid
into sump basin. Check valve should be a free flow valve that will easily pass solids.

NOTICE:

For best performance of check valve when handling solids, do not install it

with discharge angled more than 45° above the horizontal. Do not install check valve
in a vertical position as solids may settle in valve and prevent opening on startup.

Drill a 3/16" (4.7mm) hole in discharge pipe about 1"-2" (2.5 - 5.1cm) above pump
discharge connection (but below check valve) to prevent airlocking the pump.

Содержание S44018T

Страница 1: ...MANUAL Sewage Ejector Pump 2005 S587 Rev 6 2 05 Model S44018T Installation Operation Parts For further operating installation or maintenance assistance Call 1 888 782 7483 293 Wright Street Delavan W...

Страница 2: ...t they will be free from defects in material and workman ship for the Warranty Period from the date of original installation or manufacture as noted Product Warranty Period Water Systems Products jet...

Страница 3: ...be capable of handling semi solids of at least 2 5 1 cm diameter The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid To meet minimum flow requirements 2 feet...

Страница 4: ...upply informa tion Voltage Hertz Phase on pump motor nameplate matches incoming power supply exactly Install pump according to all electrical codes that apply FPSE Individual Branch Circuit Dual Eleme...

Страница 5: ...n reconnect to power source Check for cause of overheating overloading 1 Be sure all valves in discharge valve are fully open 2 Clean out discharge pipe and check valve 3 Check for blockage in pump in...

Страница 6: ...Part S440118T No Description Qty 115 Volt 1 Lower Volute 1 PW1 11P 2 Impeller 1 PW5 15P 3 Upper Volute 1 PW1 10P 4 Power Cord 1 PS117 53 TSE 5 Automatic Float Switch 1 PW217 179B 4 3 2 1 5 IF MOTOR F...

Страница 7: ...para aguas residuales 2005 S587 Rev 6 2 05 Modelo S44018T Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 888 782 7483 2...

Страница 8: ...Al hacer una reparaci n reemplace este aceite por aceite nuevo ADVERTENCIA ADVERTENCIA PRECAUCI N ADVERTENCIA PELIGRO GARANTIA LIMITADA Sta Rite Industries garantiza al consumidor original de los pro...

Страница 9: ...a velocidad del flujo en la tuber a de descarga debe poder mantener los s lidos en suspensi n en el l quido Para mantener el caudal m nimo necesario velocidad de 2 pies o 0 6 m por segundo en el ca o...

Страница 10: ...n mero de fases inscrita en la chapa del motor de la bomba corresponde exactamente a la de la corriente el ctrica utilizada Instale la bomba en conformidad con todos los c digos de electricidad que c...

Страница 11: ...corriente el ctrica Investigue la causa del sobrecalentamiento o sobrecarga 1 Aseg rese de que todas las v lvulas en la tuber a de descarga est n totalmente abiertas 2 Limpie el ca o de descarga y ve...

Страница 12: ...zas Cantidad 115 Volt 1 Voluta inferior 1 PW1 11P 2 Rodete 1 PW5 15P 3 Voluta superior 1 PW1 10P 4 Cable de alimentaci n 1 PS117 53 TSE 5 Interruptor autom tico de flotador 1 PW217 179B 4 3 2 1 5 LIST...

Отзывы: