background image

9

ADAPTER INSTALLATION

Use PVC cement to attach a 1-1/2” PVC socket-to-thread adapter (not sup-
plied) to raised collar on filter base to allow attachment of an elbow and hose
for:
1. vacuuming pool, putting water to waste (see Page 12);
2. draining;
3. lowering water level in pool or spa/tub (see Figure 17).

Flammable and poisonous fumes. Use cement only in a well

ventilated area away from flame;  follow manufacturer’s instructions.

FILTER ASSEMBLY

1. Replace plugs or close valves in Tank Drain and Auxiliary Drain ports.
2. Push clean air bleed filter all the way down on tube. If tube has been re-

moved, push it into socket seat in base until it bottoms.

3. Set filter element on base.

NOTICE: 

Be sure blue end marked “TOP” is on top and red end is on bot-

tom. Do not reverse element.

4. Push filter element into base between two circular ribs until it bottoms.
5. Inspect and clean the tank flanges and upper and lower O-Ring seats. If

flanges are deformed, cracked, or corroded, replace entire filter.

6. Reinstall O-Ring. Reinstall tank head. See below for a list of approved 

O-Ring lubricants. 

NOTICE: 

On multiple-clamp units, clamp/O-Ring sets are not interchange-

able. When replacing more than one clamp, refer to Parts List, Page 14, for
correct location.

Do not remove or damage safety and instruction labels during

cleaning. Replace any decals which may have been damaged.

7. If bottom clamp was removed, BE SURE bottom of tank body is clean; set 

tank body evenly on base and “O” Ring.

8. Install clamp(s) and knob assembly(s); Tighten clamps equipped with 

knobs

firmly hand tight. Tighten clamps equipped with 

nuts

to 20-30 in. lbs. (23-35

cm-kg) torque. The final gap between the clamp ends should be 1/4 to 3/8”
(6 to 9.5 mm).

9. Clean pump strainer basket.

10. Open system valves as needed.

11. Proceed to “Startup”, Page 7.

STA-RITE APPROVED O-RING LUBRICANTS

Petroleum Jelly (Vaseline)

Semi-Permanent Lubrication

Parker Super-O-Lube*

Semi-Permanent Lubrication

Aqua-Lube by Allube**

Semi-Permanent Lubrication

5% or less Mild Soap Solution

Assembly Lubrication

* Parker Seal Group, Lexington, KY

** Allube Div. of Far Best Corp., Los Angeles, CA

Filter
Base

Filter
Element

Air Bleed Tube

Air Bleed Tube Filter

Move Filter

Element to one

side to Break 

Bottom Seal

Bottom

Seal Ring

574 0993

1-1/2" Female

Pipe Thread

Socket End

1-1/2" PVC

Socket to

Female

Thread Adapter

Filter

Base

Built In

Raised Collar

559 0993

Final gap
should be
1/4-3/8"

2030 0995

Discard clamp if 
it is bent or
twisted

Discard clamp if 
rivets are corroded
or cracked or welds
are broken

Discard clamp
if threads of 
bolt, nut, or knob
 are stripped or worn

FIGURE 7B – Clamp Inpection
Procedure

FIGURE 10

FIGURE 8

LIFT FILTER ELEMENT

STRAIGHT UPWARD

TO REMOVE

Filter Base

803 0294

FIGURE 9

Содержание PTM100

Страница 1: ...ION PARTS MODELS PTM50 PTM70 PTM100 PTM135 Sta Rite Pool Spa Group 2004 Sta Rite Industries Printed in U S A S294 Rev 3 30 04 Furnish this manual to the end user of this filter its use will reduce ser...

Страница 2: ...reliable Table of Contents Safety Instructions 3 General Information 4 Installation General 5 Installation Assembling Filter 6 7 Startup 7 Filter Disassembly Assembly 8 9 Filter Cleaning Procedure 10...

Страница 3: ...ssure or city water system 2 Use equipment only in a pool or spa installation 3 Trapped air in system can cause explosion BE SURE all air is out of system before operating or testing equipment Before...

Страница 4: ...amps are in place and knobs are securely tightened before starting filter Maintain pressure gauge in good working order Replace gauge if it fails or is damaged Make sure internal air bleed tube and ai...

Страница 5: ...ency use fewest possible fittings Keep piping tight and free of leaks pump suction line leaks may cause trapped air in filter tank or loss of prime at pump pump discharge line leaks may show up as dam...

Страница 6: ...y have to push down on top of tank head while installing clamp 10 Tighten clamp firmly hand tight tap clamp around tank with rubber ham mer while tightening to aid sealing 11 Attach pressure gauge and...

Страница 7: ...rtup open the air release valve and make sure that it is running a solid stream of water before putting the filter in service 2 Start pump 3 When a steady stream of water comes from air release valve...

Страница 8: ...To prevent severe or fatal injury make sure that all pressure has been released from filter tank before proceeding 6 Remove clamp fastener from clamp indicated in Figures 6A and 6B 7 Loosen indicated...

Страница 9: ...mage safety and instruction labels during cleaning Replace any decals which may have been damaged 7 If bottom clamp was removed BE SURE bottom of tank body is clean set tank body evenly on base and O...

Страница 10: ...ssible Figure 14 NOTICE BE SURE all dirt and foreign materials are washed away from INSIDE pleats of element SPECIAL CLEANING INSTRUCTIONS Risk of fire or explosion Isolate filter from system before c...

Страница 11: ...to waste bypass ing filter is desirable proceed as follows 1 Disassemble filter Hazardous pressure Filter may explode if incorrectly disas sembled To avoid severe injury or major property damage exac...

Страница 12: ...an cause components to explode with risk of severe injury or death to anyone nearby Use only a low pressure below 5 PSI high volume blower when air purging the pump filter or piping NOTICE Filter must...

Страница 13: ...impeller and diffuser worn replace with new parts Consult pump owner s manual for in formation 6 Pump too small for system replace with larger pump C Pool Water Not Clear 1 Chlorine dosage too low ma...

Страница 14: ...104 78P WC104 78P 11 Pipe Plug 2 WC78 38T WC78 38T WC78 38T WC78 38T 12 Clamp Nut 1 WC36 1 WC36 1 WC36 1 WC36 1 13 Air Bleed Tube 1 25010 0007 25010 0007 25010 0008 25010 0010 14 Air Bleed Filter 1 WC...