background image

12

LIMITED WARRANTY

Sta-Rite warrants to the original consumer of the products listed below, that they will be free from defects in
material and workmanship for the Warranty Period from the date of original installation or manufacture as noted.

Product

Warranty Period

Water Systems Products – jet pumps,

whichever occurs first:

small centrifugal pumps, submersible pumps

1 year from date of original installation, or

and related accessories

2 years from date of manufacture

Con-Aire

®

tanks

5 years from date of original installation

Epoxy-Line Tanks

3 years from date of original installation

Environmental Products

1 year from date of original installation, or
2 years from date of manufacture

Our warranty will not apply to any product that has been subject to negligence, misapplication, improper instal-
lation or maintenance. In the event a three phase submersible motor is operated with single phase power
through a phase converter, or if three-leg ambient compensated, extra-quick trip overload relays of recom-
mended size are not used, our warranty is void.

Buyer’s only remedy and Sta-Rite’s only duty is to repair or replace defective products (at Sta-Rite’s choice).
Buyer agrees to pay all labor and shipping charges associated with this warranty and to request warranty ser-
vice through the installing dealer as soon as a problem is discovered. If warranty service is requested more
than 30 days after the Warranty Period has ended, it will not be honored.

STA-RITE SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAM-
AGES WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WAR-
RANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE
WARRANTY PERIOD PROVIDED HEREIN.

Certain states do not permit the exclusion or limitation of incidental or consequential damages or the placing of
limitations on the duration of an implied warranty, therefore, the limitations or exclusions herein may not apply.
This warranty sets forth specific legal rights and obligations, however, additional rights may exist, which may
vary from state to state.

Supersedes all previous publications

Sta-Rite Industries, Inc. 293 Wright St., Delavan, WI  53115

Содержание PNB-1L

Страница 1: ...ON AND OPERATING INSTRUCTIONS REPAIR PARTS LIST Corrosion Resistant Shallow Well Jet Pump PRINTED IN U S A S151 Rev 4 17 95 MODELS 1 3 HP 1 2 HP 3 4 HP PNB 1L PNC 1L PND 1L PNCSS STA RITE INDUSTRIES INC DELAVAN WISCONSIN 53115 ...

Страница 2: ...areas To avoid over pressure hazard and possible injury install pressure relief valve capable of passing full pump flow at 75 PSI Pressurized suction may cause pump body to explode Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling IMPORTANT TANK SYSTEMS Be sur...

Страница 3: ...servicing Leave room to use wrenches 10 Pump body may explode if used as booster pump unless relief valve capable of passing entire pump flow at 75PSI is installed 11 Be sure to prime pump before starting Water acts as lubricant Starting without water will cause internal damage and void war ranty PUMP PIPING INSTALLATION PUMP INSTALLATION NOTICE Use Teflon tape supplied with pump for making all th...

Страница 4: ... and AVC for details PRE CHARGED TANK CONNECTION FIG 5 When pre charged tank is used no AVC is necessary Pre charged tank contains factory provided air charge NOTICE Your pump pressure switch is set for a 30 50 PSI range and requires tank pre charge of 28 PSI for proper operation See tank owner s manual for instructions on checking tank air charge An annual check on tank charge is recommended to p...

Страница 5: ...rime and fail to pump Install foot valve 10 20 ft below lowest level to which water will drop while pump is oper ating pumping water level Contact your local well driller for more information 3 To prevent sand and sediment from entering pumping system foot valve strainer should be at least 5 ft above bottom of well 4 When proper depth is reached install sanitary well seal over pipe and in well cas...

Страница 6: ... is perma nently grounded otherwise serious or fatal electrical shock haz ard may be caused 4 For best ground connection connect to grounded lead in service panel or to metal underground water pipe or well casing at least 10 ft long If plastic pipe or insulated fittings are used run ground wire directly to metal well casing or use ground electrode furnished by the power company TO CONNECT PRESSURE...

Страница 7: ...nnect power 2 Remove pressure switch tube from pump body and allow pump to drain 3 Remove four hexnuts Key No 23 Page 11 which hold the pump body to the motor 4 Remove motor seal plate impeller and diffuser Key Nos 1 3 7 9 Page 11 as a unit 5 Carefully insert an icepick or other small diameter pointed tool into venturi Key No 17 Page 11 and into nozzle behind ven turi Key No 16 Page 11 dislodging ...

Страница 8: ... sure it is free of dirt foreign particles scratches and grease 6 Inspect shaft to be sure it is free of nicks and scratches 7 Reinstall seal plate on motor flange making sure that it is right side up index pins down top of plate is marked 8 Apply liquid detergent sparingly to inside diameter of rotating seal member 9 Slide rotating seal member carbon face first onto shaft until rub ber drive ring...

Страница 9: ... 17 Since the gases rise in the well casing the water sucked down through the pipe and into the suction pipe is free of gas This type of well must be vented to the outside of any enclo sure AIR CONTROL IN FLOWING WELLS Flowing wells or wells with little or no drawdown could create a special problem in air control in the operation of your water sys tems In such cases install a Con Aire Tank It does...

Страница 10: ...ry pipes below frost line Heat pit or pump house Foot valve and or strainer are Raise foot valve and or strainer above well bottom buried in sand or mud Water level in well A deep well jet pump or submersible is needed is below 25 Pump does not Water level in well is lower than A larger pump may be needed deliver water to full estimated capacity Steel piping if used is corroded or Replace with pla...

Страница 11: ...8SS U30 738SS U30 738SS 11 Tank Body Ass y incl 12 thru 18 1 N176 35P N176 35P N176 35PA N176 35P 12 Tank Body 1 N76 35P N76 35P N76 35P N76 35P 12A Pipe Plug 1 8 NPT Taped 1 WC78 41T WC78 41T WC78 41T WC78 40T 13 Gasket Plastic 1 J20 18 J20 18 J20 18 J20 18 14 Tank Jet Body Insert 1 N76 29P N76 29P N76 29P N76 29P 15 Capscrew 10 16 4 U30 742SS U30 742SS U30 742SS U30 742SS 16 Nozzle 1 N34P 19 N34...

Страница 12: ...warranty is void Buyer s only remedy and Sta Rite s only duty is to repair or replace defective products at Sta Rite s choice Buyer agrees to pay all labor and shipping charges associated with this warranty and to request warranty ser vice through the installing dealer as soon as a problem is discovered If warranty service is requested more than 30 days after the Warranty Period has ended it will ...

Отзывы: