background image

8

Drain all water from pump and piping when expecting freezing temperatures
or when storing pump for a long time (see instructions below).
Keep motor dry and covered during storage.
To avoid condensation/corrosion problems, do not cover pump with plastic.
For outdoor/unprotected installations:
1. Enclose entire system in a weatherproof enclosure.

2. To avoid condensation/corrosion damage, allow ventilation; do not wrap

system in plastic.

3. Use a 40% propylene glycol/60% water solution to protect pump to -50°F

(-46°C).

Draining Pump

1. Pump down water level below all inlets to the pool.

To avoid dangerous or fatal electrical shock hazard, turn OFF power to

motor before draining pump.

2. Remove trap cover and use low pressure air to blow accumulated water

from the piping system. Use a Sta-Rite U79-11 Lid Wrench to remove trap
covers that have been overtightened or have taken a set and cannot be re-
moved by hand.

3. Cap inlet piping after draining to keep water out of the pipes.

4. To prevent pump from freezing, remove the trap cover and drain the tank

body through the two drain plugs provided. Clean pump thoroughly; re-
place trap cover.

NOTICE: Tighten trap cover by hand only (no wrenches)! Use a wrench
only if necessary to remove cover.

5. Be sure motor is kept dry and covered.

Startup For Winterized Equipment

1. Remove any temporary weather protection placed around system for shut-

down.

2. Follow filter manufacturer’s instructions for reactivation of the filter.

3. Inspect all electrical wiring for damage or deterioration over the shutdown

period. Have a qualified serviceman repair wiring as needed.

4. Inspect and tighten all watertight connections.

5. Open all valves in suction and return piping.

6. Remove any winterizing plugs in piping system.

7. Drain all antifreeze from system.

8. Close all drain valves and replace all drain plugs in piping system.

9. Prime pump according to instructions on Page 7.

Hazardous voltage.
Can shock, burn,
or cause death.

Disconnect power
before working
on pump or motor.

Содержание PE5YD-133L

Страница 1: ...ta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728 4461 TELEX ITT 4970245 Oxnard CA Union City TN Delavan WI M...

Страница 2: ...ULLY The Sta Rite PE and PEA Series Self priming Centrifugal pumps Are designed for use with swimming pools or as centrifugal pumps Are excellent performers durable reliable Table of Contents Safety I...

Страница 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Страница 4: ...to pump with union half use Teflon tape or Plasto Joint Stik between pipe and union adapter Union collar to pump should be assembled dry and hand tight NOTICE Pump suction and discharge connections h...

Страница 5: ...conform to International Association of Plumbing and Mechanical Officials IAPMO standards Use only non entrapping suction fitting or double suction TABLE I RECOMMENDED FUSING AND WIRING DATA Serv to...

Страница 6: ...e required by code Connect motor ground terminal to electrical service ground Bond motor to pool structure Use a solid copper conductor size No 8 AWG 8 4 sq mm or larger Run wire from external bonding...

Страница 7: ...er fill trap and pump with water Lubricate trap cover O Ring with petroleum jelly each time it is removed Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to...

Страница 8: ...d by hand 3 Cap inlet piping after draining to keep water out of the pipes 4 To prevent pump from freezing remove the trap cover and drain the tank body through the two drain plugs provided Clean pump...

Страница 9: ...ure in trap body remove cover unscrew by turn ing counterclockwise 3 Remove clamp holding pump halves together 4 Remove pump base mounting bolts if used Motor and seal plate assem bly can now be pulle...

Страница 10: ...l in seal plate NOTICE On 2 HP models install impeller screw left hand thread turn counterclockwise 8 Mount diffuser on seal plate tighten screws to 10 14 inch lbs 11 2 16 1 kg cm torque 9 Assemble mo...

Страница 11: ...er is not clogged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 10 for reassembly 8 Impeller and diffuser...

Страница 12: ...12 1 2 3 4 19 20 8 5 6 9 10 11 14 15 16 12 13 17 18 7 21 2243 0196 PE and PEA Series MAX E GLAS 2 Speed Pool Pump 3 4 1 and 2 HP Models...

Страница 13: ...s U27 67 Tag CAUTION This pump equipped C63 13 with mech shaft seal Tag CAUTION Securely tighten and C63 10 center trap cover prior to pressure testing Nameplate U33 121 Not illustrated Models PEAXYG...

Страница 14: ...haul Kits HP Parts Pak Number 3 4 PP1014 1 PP1016 Kit includes Impeller Diffuser Shaft Seal Gaskets O Rings Hardware Shims Wear Rings and Inserts Seal Gasket Kit Kit includes Shaft Seal Gaskets and O...

Страница 15: ...nce misapplication im proper installation or maintenance or other circumstances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...

Страница 16: ...16...

Отзывы: