READ AND FOLLOW SAFETY 
INSTRUCTIONS!

This is the safety alert symbol. When you see this symbol on your system

or in this manual, look for one of the following signal words and be alert

to the potential for personal injury.

warns about hazards that will cause death, serious personal 

injury, or major property damage if ignored.

warns about hazards that can cause death, serious personal 

injury, or major property damage if ignored.

warns about hazards that will or can cause minor personal injury

or property damage if ignored.

NOTICE indicates special instructions not related to hazards.

Carefully read and follow all safety instructions in this manual and on equip-
ment. 
Keep safety labels in good condition; replace if missing or damaged.

Incorrectly installed or tested equipment may fail, causing
severe injury or property damage. 
Read and follow instructions in owner's manual when installing
and operating equipment. Have a trained pool professional per-

form all pressure tests.
1. Do not connect system to a high pressure or city water system.
2. Use equipment only in a pool or spa installation.
3. Trapped air in system can cause explosion. BE SURE all air is out of system

before operating or testing equipment.

Before pressure testing, make the following safety checks:

• Check all clamps, bolts, lids, and system accessories before testing.
• Release all air in system before testing.
• Tighten Sta-Rite trap lids to 30 ft. lbs. (4.1 kg-m) torque for testing.
• Water pressure for test must be less than 25 PSI (7.5 kg/cm2).
• Water Temperature for test must be less than 100

o

F. (38

o

C).

• Limit test to 24 hours. After test, visually check system to be sure it is ready

for operation. Remove trap lid and retighten hand tight only.
NOTICE: These parameters apply to Sta-Rite equipment only. For 
non-Sta-Rite equipment, consult manufacturer.

IMPORTANT
SAFETY 
INSTRUCTIONS

Always follow basic safety pre-
cautions with this equipment, in-
cluding the following.

To reduce the risk of

injury, do not permit children to
use this product unless they are
closely supervised at all times.

This pump is for use

with permanently installed pools
and may also be used with hot
tubs and spas if so marked. Do
not use with storable pools. A
permanently installed pool is con-
structed in or on the ground or in
a building such that it cannot be
readily disassembled for storage.
A storable pool is constructed so
that it may be readily disassem-
bled for storage and reassembled
to its original integrity.

SAVE THESE 
INSTRUCTIONS

Содержание PE5YD-133L

Страница 1: ...ta Rite Pool Spa Group 293 Wright Street Delavan WI 53115 North America 800 752 0183 FAX 800 582 2217 International 414 728 5551 FAX 414 728 4461 TELEX ITT 4970245 Oxnard CA Union City TN Delavan WI M...

Страница 2: ...ULLY The Sta Rite PE and PEA Series Self priming Centrifugal pumps Are designed for use with swimming pools or as centrifugal pumps Are excellent performers durable reliable Table of Contents Safety I...

Страница 3: ...BE SURE all air is out of system before operating or testing equipment Before pressure testing make the following safety checks Check all clamps bolts lids and system accessories before testing Releas...

Страница 4: ...to pump with union half use Teflon tape or Plasto Joint Stik between pipe and union adapter Union collar to pump should be assembled dry and hand tight NOTICE Pump suction and discharge connections h...

Страница 5: ...conform to International Association of Plumbing and Mechanical Officials IAPMO standards Use only non entrapping suction fitting or double suction TABLE I RECOMMENDED FUSING AND WIRING DATA Serv to...

Страница 6: ...e required by code Connect motor ground terminal to electrical service ground Bond motor to pool structure Use a solid copper conductor size No 8 AWG 8 4 sq mm or larger Run wire from external bonding...

Страница 7: ...er fill trap and pump with water Lubricate trap cover O Ring with petroleum jelly each time it is removed Clean and inspect O Ring reinstall on trap cover Replace trap cover on trap turn clockwise to...

Страница 8: ...d by hand 3 Cap inlet piping after draining to keep water out of the pipes 4 To prevent pump from freezing remove the trap cover and drain the tank body through the two drain plugs provided Clean pump...

Страница 9: ...ure in trap body remove cover unscrew by turn ing counterclockwise 3 Remove clamp holding pump halves together 4 Remove pump base mounting bolts if used Motor and seal plate assem bly can now be pulle...

Страница 10: ...l in seal plate NOTICE On 2 HP models install impeller screw left hand thread turn counterclockwise 8 Mount diffuser on seal plate tighten screws to 10 14 inch lbs 11 2 16 1 kg cm torque 9 Assemble mo...

Страница 11: ...er is not clogged follow steps 1 through 7 under Removing Old Seal Page 9 check impeller for clogging follow steps 7 through 11 under Installing New Seal Page 10 for reassembly 8 Impeller and diffuser...

Страница 12: ...12 1 2 3 4 19 20 8 5 6 9 10 11 14 15 16 12 13 17 18 7 21 2243 0196 PE and PEA Series MAX E GLAS 2 Speed Pool Pump 3 4 1 and 2 HP Models...

Страница 13: ...s U27 67 Tag CAUTION This pump equipped C63 13 with mech shaft seal Tag CAUTION Securely tighten and C63 10 center trap cover prior to pressure testing Nameplate U33 121 Not illustrated Models PEAXYG...

Страница 14: ...haul Kits HP Parts Pak Number 3 4 PP1014 1 PP1016 Kit includes Impeller Diffuser Shaft Seal Gaskets O Rings Hardware Shims Wear Rings and Inserts Seal Gasket Kit Kit includes Shaft Seal Gaskets and O...

Страница 15: ...nce misapplication im proper installation or maintenance or other circumstances which are not in Sta Rite s direct control Full warranty coverage is in effect for one year after instal lation The pro...

Страница 16: ...16...

Отзывы: