background image

10 

MAX-E-PRO

®

 Pool and Spa Pump Installation and User’s Guide

Parts List 

(for Models P6EA6D36-204 and P6EA6E36-205)

For quick disconnect pipe connections, 
purchase separately: 
Pkg. 188 2” Slip 1/2 Union Kit or
Pkg. 189 2” NPT 1/2 Union Kit.

Kit Includes:

U11-200PS Union Collar
U9-362 O-Ring
U11-196PS 2” Slip adapter OR
U11-199P 2” NPT adapter.

Box A

Item #

Part #

Part Description

Qty.

1

See Table on 

Page 11

Motor

1

2

U30-692SS

Screw, #10-32 x 1/2”

1

2A

U43-22SS

Lock Washer

1

3

U17-568

Bonding Lug

1

4

C2-84

Pump Adapter

1

5

U30-74SS

Screw, 3/8-16 x 1” Hex Head

4

6

U30-754SS

Stub Shaft Pins

3

7

C10-41SS

Stub Shaft

1

8

17351-0009

Water Slinger

1

9

C203-194P

Seal Plate Kit (Incl. Item# 10-11)

1

10

U9-228A

O-Ring, Seal Plate to Housing (for 

pumps built before January 2015)

1

357099

Gasket, Seal Plate to Housing (for 

pumps built in February 2015 or later)

11

17351-0101S

Shaft Seal

1

12

C19-37A

Band Clamp

1

13

WC36-22

Band Clamp Knob

1

14

See Table on 

Page 11

Impeller

1

-

35505-1426

Impeller Screw O-Ring

1

-

See Table on 

Page 11

Impeller Screw

1

15

See Table on 

Page 11

Diffuser

1

16

U9-374

Diffuser O-Ring

1

16

357098Z

Diffuser O-Ring (Blue Coating)

1

17

U43-21SS

Lock Washer, #8

5

18

U30-922SS

Screw (w/C1-271P Diffuser)

5

U30-542SS

Screw (w/C1-271P1 Diffuser)

Item #

Part #

Part Description

Qty.

19

17307-0110S

Trap Body Assembly (Incl. Item# 20-23)

1

20

17307-0111S

Trap Cover Assembly (Incl. Trap Cover  
and Item# 21)

1

21

35505-1440

Trap O-Ring

1

22

C8-58P

Basket

1

23

U178-920P

Drain Plug, 1/4” NPT

2

24

U43-41SS

Washer, Motor Base

2

25

U30-918SS

Screw, Motor Base

2

26

See Table on 

Page 11

Motor Base

1

27

See Table on 

Page 11

Motor Pad

1

(-) 

Note

: Not shown

1

6

9

15

18

17

14

8

25

7

26

27

13

10

11

24

3

2

2A

5

4

23

21

20

22

19

16

12

See Box A for Union 

Part Numbers

Exploded Parts View 

(for Models P6EA6D36-204 and P6EA6E36-205)

Содержание MAX-E-PRO P6E6C-204L

Страница 1: ...MAX E PRO POOL AND SPA PUMP IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE...

Страница 2: ...DOES NOT PROTECT AGAINST BODY OR LIMB ENTRAPMENTS DISEMBOWELMENTS WHEN A PERSON SITS ON A BROKEN OR UNCOVERED POOL DRAIN OR HAIR ENTANGLEMENTS THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A...

Страница 3: ...vacuum release system SVRS meeting ASME ANSI A112 19 17 Manufactured Safety Vacuum Release systems SVRS for Residential and Commercial Swimming Pool Spa Hot Tub and Wading Pool Suction Systems and or...

Страница 4: ...and P6EA6E36 205 Motor Impeller Diffuser Table 6 6 6 7 8 9 9 9 10 10 11 Customer Service and Technical Support USA 8 A M to 4 30 P M Eastern Pacific Times Phone 800 831 7133 Fax 800 284 4151 Web site...

Страница 5: ...systems must have a gate valve in both the suction and discharge pipes 6 For most installations Pentair recommends installing a valve on both the pump suction and return lines so that the pump can be...

Страница 6: ...ning see Figure 2 However if two main drains run into a single suction line the single suction line may be equipped with a valve which will shut off both main drains from the pump see Figure 2 More th...

Страница 7: ...anadian installations a 6 AWG or larger solid copper bonding conductor is required Run a wire from the external bonding screw or lug to the bonding structure 2 Connect the wire from the accessible bon...

Страница 8: ...ain proper water level If the water level falls below the suction port the pump will draw air through the suction port losing the prime and causing the pump to run dry resulting in a damaged seal Cont...

Страница 9: ...porary weather protection placed around system for shutdown 2 Follow filter manufacturer s instructions for reactivation of the filter 3 Inspect all electrical wiring for damage or deterioration over...

Страница 10: ...rds the pipe connection port between ribs provided If the basket is replaced backwards the lid will not fit on the strainer pot 7 Clean and inspect the lid O Ring and reinstall on strainer groove 8 Cl...

Страница 11: ...diameter of the rotating seal member 6 Slide the rotating seal member polished carbon face outwards over the impeller sleeve until rubber drive ring hits the back of the impeller Note Be sure not to s...

Страница 12: ...s clean the basket and pot Ensure impeller is not clogged Disassemble the pump according to Pump Disassembly on page 6 If a blockage in the impeller if found clear the blockage and reassemble the pump...

Страница 13: ...peller 1 8 35505 1426 Impeller Screw O Ring 1 9 See Table on Page 11 Impeller Screw 1 10 See Table on Page 11 Diffuser 1 11 U9 374 Diffuser O Ring 1 357098Z Diffuser O Ring Blue Coating 12 U43 21SS Lo...

Страница 14: ...r pumps built in February 2015 or later 11 17351 0101S Shaft Seal 1 12 C19 37A Band Clamp 1 13 WC36 22 Band Clamp Knob 1 14 See Table on Page 11 Impeller 1 35505 1426 Impeller Screw O Ring 1 See Table...

Страница 15: ...238PBA C105 238PDBA C105 238PEBA C105 238PLA C1 271P C1 271P1 C1 271P1 C1 271P C105 238PA C105 238PBA C105 238PDBA C105 238PDBA C1 271P P6EA6F36 206 1 1 2 62001 1019S P6EA6G36 207 2 62003 2087 P6E6H36...

Страница 16: ...d brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Those...

Отзывы: