background image

MAX-E-PRO

®

 Pool and Spa Pump Installation and User’s Guide

This pool pump must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical 
Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious 
injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.

Always disconnect power to the pool pump at the circuit breaker before servicing the pump. Failure to do so could result in death 
or serious injury to serviceman, pool users or others due to electric shock.

Read all servicing instructions before working on the pump.

MAINTENANCE

Cleaning the Strainer Basket 

The only routine maintenance needed is inspection/
cleaning of the strainer basket. Debris or trash that collects 
in the basket will choke off water flow through the pump. 
Follow the instructions below to clean the strainer basket:
1.  Disconnect power to the pump at the circuit breaker.
2.  Close all gate valves in the suction and discharge lines.
3.  Release all pressure from the pump and piping system.
4.  Remove strainer lid (turn counter-clockwise). If 

necessary, tap handles gently with a rubber mallet.

5.  Remove the strainer basket and clean. Be sure all holes 

in basket are clear. 

6.  Flush basket with water and place back into the strainer 

pot.

 

Note:

 Ensure the large opening in the basket is 

oriented towards the pipe connection port (between ribs 
provided). If the basket is replaced backwards the lid 
will not fit on the strainer pot.

7.  Clean and inspect the lid O-Ring and reinstall on 

strainer groove.

8.  Clean the O-Ring groove on the strainer pot and 

reinstall the lid/locking ring. 

 

Note: 

To prevent sticking, hand tighten only.

9.  Prime the pump (see 

Priming the Pump, 

page 4).

Pump Disassembly / Removing Old Seal

1.  Disconnect power to the pump at the circuit breaker.
2.  Close all gate valves in the suction and discharge 

lines.

3.  Release all pressure from the pump and piping 

system.

4.  Drain the pump by removing the drain plugs at the 

bottom of the strainer pot.

5.  Remove the band clamp that holds the pump halves 

together. The motor and seal plate assembly can now 
be pulled away from pump body.

6.  Remove the five (5) screws and washers securing the 

diffuser to the seal plate. Remove the diffuser.

7.  Carefully remove the motor canopy, being sure not to 

touch the capacitor terminals. Loosen the capacitor 
clamp and move it to one side.

8.  Hold the motor shaft with a 1/2” open-end wrench on 

the motor shaft flats.

9.  Unscrew the impeller from the motor shaft (turning 

counterclockwise when facing the impeller).
For models including a center impeller screw, remove 
the impeller screw (left-hand thread) and gasket before 
removing the impeller. Inspect the gasket for damage 
or cracks and replace if damaged.

10.  Remove the rotating seal member from the motor 

shaft.

11.  Remove the four (4) screws securing the seal plate to 

the motor.

12.  Place seal plate face down on a flat surface and tap 

out white ceramic seal (see 

Figure 4

).

13.  Clean the seal plate’s seal cavity and the motor shaft.

Figure 4

Содержание MAX-E-PRO P6E6C-204L

Страница 1: ...MAX E PRO POOL AND SPA PUMP IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTALLATION AND USER S GUIDE...

Страница 2: ...DOES NOT PROTECT AGAINST BODY OR LIMB ENTRAPMENTS DISEMBOWELMENTS WHEN A PERSON SITS ON A BROKEN OR UNCOVERED POOL DRAIN OR HAIR ENTANGLEMENTS THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A...

Страница 3: ...vacuum release system SVRS meeting ASME ANSI A112 19 17 Manufactured Safety Vacuum Release systems SVRS for Residential and Commercial Swimming Pool Spa Hot Tub and Wading Pool Suction Systems and or...

Страница 4: ...and P6EA6E36 205 Motor Impeller Diffuser Table 6 6 6 7 8 9 9 9 10 10 11 Customer Service and Technical Support USA 8 A M to 4 30 P M Eastern Pacific Times Phone 800 831 7133 Fax 800 284 4151 Web site...

Страница 5: ...systems must have a gate valve in both the suction and discharge pipes 6 For most installations Pentair recommends installing a valve on both the pump suction and return lines so that the pump can be...

Страница 6: ...ning see Figure 2 However if two main drains run into a single suction line the single suction line may be equipped with a valve which will shut off both main drains from the pump see Figure 2 More th...

Страница 7: ...anadian installations a 6 AWG or larger solid copper bonding conductor is required Run a wire from the external bonding screw or lug to the bonding structure 2 Connect the wire from the accessible bon...

Страница 8: ...ain proper water level If the water level falls below the suction port the pump will draw air through the suction port losing the prime and causing the pump to run dry resulting in a damaged seal Cont...

Страница 9: ...porary weather protection placed around system for shutdown 2 Follow filter manufacturer s instructions for reactivation of the filter 3 Inspect all electrical wiring for damage or deterioration over...

Страница 10: ...rds the pipe connection port between ribs provided If the basket is replaced backwards the lid will not fit on the strainer pot 7 Clean and inspect the lid O Ring and reinstall on strainer groove 8 Cl...

Страница 11: ...diameter of the rotating seal member 6 Slide the rotating seal member polished carbon face outwards over the impeller sleeve until rubber drive ring hits the back of the impeller Note Be sure not to s...

Страница 12: ...s clean the basket and pot Ensure impeller is not clogged Disassemble the pump according to Pump Disassembly on page 6 If a blockage in the impeller if found clear the blockage and reassemble the pump...

Страница 13: ...peller 1 8 35505 1426 Impeller Screw O Ring 1 9 See Table on Page 11 Impeller Screw 1 10 See Table on Page 11 Diffuser 1 11 U9 374 Diffuser O Ring 1 357098Z Diffuser O Ring Blue Coating 12 U43 21SS Lo...

Страница 14: ...r pumps built in February 2015 or later 11 17351 0101S Shaft Seal 1 12 C19 37A Band Clamp 1 13 WC36 22 Band Clamp Knob 1 14 See Table on Page 11 Impeller 1 35505 1426 Impeller Screw O Ring 1 See Table...

Страница 15: ...238PBA C105 238PDBA C105 238PEBA C105 238PLA C1 271P C1 271P1 C1 271P1 C1 271P C105 238PA C105 238PBA C105 238PDBA C105 238PDBA C1 271P P6EA6F36 206 1 1 2 62001 1019S P6EA6G36 207 2 62003 2087 P6E6H36...

Страница 16: ...d brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa Inc Those...

Отзывы: