![ST ST802RT1A Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/st/st802rt1a/st802rt1a_operation-manual_1356154042.webp)
Device operation
ST802RT1A, ST802RT1B
42/58
Doc ID 17049 Rev 1
Write 0180h to RN12 to set INT_EN and INT_OE_N;
Write 0010h to RN12 to set LK_DWN_EN;
Monitor PWRDWN/MDINT.
When the PWRDWN/MDINT pin asserts low, the user should read the RN11 register to see
if the LK_DWN is set, i.e. which source caused the interrupt.
7.11
LED display operation
The ST802RT1x provides 3 LED pins.
Table 31
contains a detailed description of the
operating modes, also described in
Table 4: Pin functions of the ST802RT1x
.
●
Link LED: On when 100 M or 10 M link is active. It also blinks at 10 Hz for transmit and
receive.
●
Speed LED: 100 Mbps(on) or 10 Mbps(off)
●
Activity LED: Blinks at 20 Hz when there is a half-duplex activity on the media. It is
driven on continuously if full-duplex configuration is detected, or blinks when a collision
is detected.
Table 31.
LED configuration
Mode
RN1B[9]
LED link
LED speed
LED act/col
1
1
ON for link-up
OFF for no link
BLINK for link-up + activity
ON for 100Mb
OFF for 10Mb
ON for full-duplex
BLINK for collision
2
0
ON for link-up
OFF for no link
ON for 100Mb
OFF for 10Mb
BLINK for activity
Figure 6.
LED connections