![ST ST802RT1A Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/st/st802rt1a/st802rt1a_operation-manual_1356154032.webp)
Registers and descriptors description
ST802RT1A, ST802RT1B
32/58
Doc ID 17049 Rev 1
Bit
Bit name
Description
Default
RW
Type
Type
7
Parallel Detection
Fault
1 -> A fault has been detected via the parallel detection
function (updated on read)
0 -> A fault has not been detected
0
RO
LH
6
Remote Fault
1 -> Remote fault condition detected
0 -> No remote fault condition detected
Set when link partner signaled a remote fault condition (RN05 -
bit 13) or a far-end-fault indicator was asserted. Latched, so
the occurrence of a remote fault causes the remote fault bit to
become set and remain set until it is cleared (by register read,
if no more fault is present).
0
RO
LH
5
Page Received
1 -> Link code word received (updated on read)
0 -> LCW not yet received
0
RO
LH
4
Link Partner Auto-
Negotiation Able
1 -> LP supports auto-negotiation (updated on read)
0 -> LP does not support auto-negotiation
0
RO
-
3
SP100 indicate
1 -> Speed is 100 Mb/s
0 -> Speed is 10 Mb/s
Set by auto-negotiation 100BASE-TX link control
0
RO
-
2
Link Status
1 -> Link is up (10–100 Mb/s)
0 -> Link is down
This bit is cleared at link failure and set after a register read if a
valid link is established
0
RO
LL
1
Auto-negotiation
enable
1 -> Auto-negotiation enabled
0 -> Auto-negotiation disabled
Set by RN00[12], if RN11[10] is 0 (not FX-mode)
0
RO
-
0
Jabber Detect
1 -> Jabber condition detected
0 -> No jabber condition detected.
Set at jabber condition detection, cleared only after register
read (if no more jabber condition is present).
Fixed to 0 in 100Base-X modes.
Same as RN01[1]
0
RO
LH
Table 25.
RN19 [0d25, 0x19]: Auxiliary status register (continued)