![ST L6470H Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/st/l6470h/l6470h_manual_1355485043.webp)
L6470
Programming manual
Doc ID 16737 Rev 2
43/64
9.1.17 OCD_TH
The OCD_TH register contains the overcurrent threshold value (see paragraph
for
details). The available range is from 375 mA to 6 A, steps of 375 mA as shown in
9.1.18 STALL_TH
The STALL_TH register contains the stall detection threshold value (see paragraph
for
details). The available range is from 31.25 mA to 4 A with a resolution of 31.25 mA.
9.1.19 STEP_MODE
The STEP_MODE register has the following structure:
The STEP_SEL parameter selects one of eight possible stepping modes:
Table 14.
Overcurrent detection threshold
OCD_TH [3..0]
Overcurrent detection threshold
0
0
0
0
375 mA
0
0
0
1
750 mA
…
…
…
…
…
1
1
1
0
5.625 A
1
1
1
1
6 A
Table 15.
Stall detection threshold
STALL_th [6..0]
Stall detection threshold
0
0
0
0
0
0
0
31.25 mA
0
0
0
0
0
0
1
62.5 mA
…
…
…
…
…
…
…
…
1
1
1
1
1
1
0
3.969 A
1
1
1
1
1
1
1
4 A
Table 16.
STEP_MODE register
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
SYNC_EN
SYNC_SEL
0
STEP_SEL