Only sequence switched safety transducers are permitted, as parallel connections can
lead to system errors and the activation of individual transducers cannot be identified
correctly.
n
The controllers must only be used in a room with a minimum protection of IP54.
n
The correct functioning of the systems must be checked at least once a day.
n
The user must follow the valid safety regulations and accident prevention regulations.
n
The controllers can only be used on currency circuits that have the same safety standards.
n
To protect against independent restart after a power cut or an emergency stop the
appropriate provisions have to be made.
n
The deformation distance of the safety edges and safety bumpers must be longer than
the stop path of the protected device.
n
The ventilation gaps on the back of the bumper must not be covered.
n
Walking sticks, crutches or zimmer frames may not trigger a switching command.
n
The transducer should be kept clean to ensure a safe switching command.