www.sstcomm.com
9
Index
BAUD2
BAUD1
BAUD0
Baud Rate (bps)
0
0
0
0
Reserved, don’t use
1
0
0
1
Reserved, don’t use
2
0
1
0
9600
3
0
1
1
19200
4
1
0
0
38400
5
1
0
1
57600
6
1
1
0
115200
7
1
1
1
230400
2.5 Reset Signal
GS11-MT RESET (Pin 14) is hardware reset signal input. When the RESET pin is pulled down to GND or
low to 2.88V lasting for 1 millisecond, the module will be forced to reset, and the host must wait for 250
milliseconds (typical value, after reset the module), and then the host must check the PIN10 (/RUN) and PIN20
(/ DATAEXCH). If the two pins are Logic 0, then the host can exchange data.
Содержание GS11-MT
Страница 11: ...www sstcomm com 11 3 2 The Flowchart of User Program...
Страница 17: ...www sstcomm com 17 4 2 The Flowchart of User Program...
Страница 25: ...www sstcomm com 25 6 Dimension Unit mm Front...
Страница 26: ...www sstcomm com 26 Side PCB dimension...
Страница 47: ...www sstcomm com 47 Enter the new configuration interface All of the data is set up with factory defaults...
Страница 49: ...www sstcomm com 49 If the GS11 MT has no password setting you can directly enter the save window...
Страница 58: ...www sstcomm com 58...