www.sstcomm.com
19
12
Default Gateway Address, high-byte first
13
14
15
16
Reserved, always 0
17
Reserved, always 0
18
Reserved, always 0
19
Check sum, byte 0+byte 1+…+byte 18
2. Response message--- (module->user board)
byte
Correct Response
Incorrect Response
0
Data length is 2
Data length is 2
1
0: Correct
Error code (not 0)
2
0
Extra error code
3
Check sum, byte 0+byte 1+byte 2
Check sum, byte 0+byte 1+byte 2
3. Error code
Index
Error Code
Explanation
0
1
Check sum error.
1
2
Data length error.
2
3
IP configuration mode does not exist.
4. Extra error code is always 0xFF
GS11-MT also has sending IP address reporting function (via UART).To enable the function, you must meet
the following two conditions: 1. The module is set to DHCP; 2. In the above request message table, the Byte 2 is
set to 0x01; After the user transmits the setting IP address message, the user will receive "0x2E" per second, until
the GS11-MT successfully obtain an IP address. Then the user will receive a message, and its format is shown as
follows:
IP Address Report
Содержание GS11-MT
Страница 11: ...www sstcomm com 11 3 2 The Flowchart of User Program...
Страница 17: ...www sstcomm com 17 4 2 The Flowchart of User Program...
Страница 25: ...www sstcomm com 25 6 Dimension Unit mm Front...
Страница 26: ...www sstcomm com 26 Side PCB dimension...
Страница 47: ...www sstcomm com 47 Enter the new configuration interface All of the data is set up with factory defaults...
Страница 49: ...www sstcomm com 49 If the GS11 MT has no password setting you can directly enter the save window...
Страница 58: ...www sstcomm com 58...