background image

Positioning the cabinet 

10

Operation 10
Chiller dimensions 

11

installation Procedure 

12

Step A - Place Dispenser into the hole in the bench  

12

Step B - Connect drain hose 

12

Step C - Mount Control Unit and connect Control to Pump cable 

12

Step D - Connect fluid product lines to Chiller 

13

Step E - Connect fluid product lines inside Chiller 

13

Step F - Connect Data cables 

13

Step G - Fix Dispenser in place 

14

Step H - Commissioning Freepour 

14

Step I - Assess Chiller drain plug 

14

Before first service 

14

optional procedures  

14

Changing the Dose Time 

14

Changing the Flow Rate 

15

Changing the product type badges 

15

3. oPerAting FreePour 

16

operating Modes 

16

On 16
 Manual backup 

16

bladders 16

Handling bladders 

16

daily setup Procedure 

17

operating Freepour - during service 

18

dispensing product 

18

reloading during service 

18

Reloading a 'Connect 4' Chiller 

18

Reloading a 'Connect 8' Chiller 

18

blanking 18
operating Freepour - After service 

19

daily Cleaning routine 

19

Leaving Freepour overnight 

19

Contents  

l

  

3

tAbLe oF Contents

About this guide 

1

hACCP 1

iMPortAnt inForMAtion 

4

safety First! 

4

Cleaning 5
refrigeration 5
Airflow 5
Lifting  

5

environment  

5

ALLergen AdViCe 

5

1. ProduCt oVerView 

6

system Components 

6

Services required on site 

6

overview 7
basic dosing Functions 

7

Manual dispense 

7

Dose Time                   

7

Automatic Reverse Flow 

7

2. instALLAtion oVerView & ProCedure 

8

Planning the dispense station 

8

General layout 

8

Maximum permissible distances 

8

Freepour dispenser and Control unit 

9

Positioning the Dispenser 

9

Dispenser dimensions 

9

Bench cut-out dimensions 

9

Control Unit dimensions 

9

Under bench clearance 

9

Freepour Chiller 

10

Operating temperature range 

10

Locating the cabinet 

10

Contents

2

  

l

  

Содержание Freepour

Страница 1: ...User Manual and Installation Guide This guide applies to Freepour 1 0 dispenser range Item codes JUG2 0 CM 13 JUG2 0 CM 23 JUG2 0 CM 14 JUG2 0 CM 14 www sixsimplemachines com au D00142 A05...

Страница 2: ...HACCP based Food Safety Programme This HACCP endorsement is conditional to the following requirements 1 Freepour must not be operated for more than one day without performing a full clean sanitise usi...

Страница 3: ...During Service 18 Dispensing product 18 Reloading During Service 18 Reloading a Connect 4 Chiller 18 Reloading a Connect 8 Chiller 18 Blanking 18 Operating Freepour After Service 19 Daily Cleaning Rou...

Страница 4: ...ned by a water jet This unit can be used up to an altitude of 2000 meters above sea level The unit is designed to operate in ambient temperatures between 16 C to 38 C If the unit is to be installed wh...

Страница 5: ...ternal configuration you may be able to connect all bladders loaded or as few as one bladder at time IMPORTANT Only approved varieties of milk and fruit juice may be dispensed Approved varieties of mi...

Страница 6: ...lows for a variety of installation configurations to suit your dispense station layout When deciding where each of the three units will be located consider how the machine will be used in service relo...

Страница 7: ...ed to site on standard height castors Short roller style castors can be supplied by request and fitted on site Operation Automatic Start Up Connect the cabinet to the mains power supply and check oper...

Страница 8: ...firmly up to the fitting at the base of the tap Observe the stickers on the protective sleeves showing the tap and Chiller ends of the sleeve 2 Feed insulation over the fluid product lines Fasten in...

Страница 9: ...hanged for example to slow the rate of dispense into an unusual shaped vessel to reduce the chance of overfilling Changing the Dose Time Use the interface on the Control Unit to change the Dose Time 1...

Страница 10: ...g features are not active In the event that the electronics are malfunctioning Freepour can still dispense milk as long as the internal power supply and pumps are still active No dosing and programmin...

Страница 11: ...e Control Unit MENU CLEANING ROUTINE 2 Remove trays with empty bladders Discard empty bladders and wash the trays 3 Remove trays with partially full bladders To prevent bladders leaking from the cap f...

Страница 12: ...setpoint be changed unless it is absolutely necessary and then only by small increments at a time To view and adjust the temperature setpoint 1 Press and hold the set button until the controller displ...

Страница 13: ...or more frequently if required See page 23 for instructions on how to clean the condenser coil IMPORTANT Unplug the cabinet from the power supply before cleaning the condenser coil Over time dust may...

Страница 14: ...shown on screen If the NO CURRENT error is displayed on screen The pump cable may have become disconnected The circuit breaker s may have tripped A pump may be jammed or The pump s may have failed Rec...

Страница 15: ...where this is not permitted If the red caps are being used to in the BLANK orientation on certain connectors in the Chiller small amounts of milk will spray into the Chiller after each dose and Automa...

Страница 16: ......

Страница 17: ...mple Machines we are always looking for ways to improve our products The illustrations in this guide may differ slightly from the actual product Made in Australia D00142 A05 l 2020 SIX SIMPLE MACHINES...

Отзывы: