FreePour disPenser And ControL unit

Positioning the disPenser

There is no set distance that the Dispenser needs to be relative to the edge of the bench. Consider that the 

height of the bench and how far the Dispenser is placed in from the edge of the bench will effect access to 

the Dispenser for people of different heights.

disPenser diMensions

 

Single 

Double 

Triple 

Single Tall 

Double Tall 

Triple Tall

benCh Cut-out diMensions

A rectangular hole in the bench is required to set the dispenser into the bench surface. A flange runs around 

the perimeter of the dispenser and covers the edge of the cut-out similar to a top mount sink.  

 

Single 

Double 

Triple 

Single Tall 

Double Tall 

Triple Tall

ControL unit diMensions

If a triple tap dispenser has been chosen or 2 x 

double tap dispensers are running from a single 

chiller, 2 x Control Units will have been supplied.

under benCh CLeArAnCe

Space is required below the Dispenser to allow 

room for the dispenser drain. This is measured 

from the TOP surface of the bench.

max

400

<400

<400

PLAnning the disPense stAtion

The modular design of Freepour allows for a variety of installation configurations to suit your dispense station 

layout. When deciding where each of the three units will be located, consider how the machine will be used 

in service, reloaded by staff and cleaned at the end of the day. 

You should also consider whether the Chiller will be set on castors and therefore will be movable allowing 

staff to clean under and behind it, or whether the Chiller will be on a plinth and will not be movable. Flexible 

fluid product lines and data cables run between the Chiller and the dispenser. It is important that these lines 

are not kinked, squashed or disconnected when moving the Chiller or accessing adjacent equipment.

generAL LAyout

The Dispenser may be placed to the left, right or directly above the Chiller. The Control Unit is most 

commonly mounted on the side of the Chiller that is closest to the Dispenser. It can however be set 

elsewhere so long as the maximum permissible distances and clearances are observed.

MAxiMuM PerMissibLe distAnCes

The maximum distance between the Dispenser and Chiller is 400mm, measured from the centre of the 

Dispenser to the closest edge of the Chiller.  

The maximum distance between the Dispenser and Control Unit is 1.2 meters. The Control Unit must be no 

more than 2 meters from the Chiller measured from the centre of the Control Unit to the centre of the Chiller.

<1200

<2000

>1200

<2000

Dimensions shown in mm

2. Installation Overview & Procedure

Installation Overview & Procedure  

l

  

9

8

  

l

  

Содержание Freepour

Страница 1: ...User Manual and Installation Guide This guide applies to Freepour 1 0 dispenser range Item codes JUG2 0 CM 13 JUG2 0 CM 23 JUG2 0 CM 14 JUG2 0 CM 14 www sixsimplemachines com au D00142 A05...

Страница 2: ...HACCP based Food Safety Programme This HACCP endorsement is conditional to the following requirements 1 Freepour must not be operated for more than one day without performing a full clean sanitise usi...

Страница 3: ...During Service 18 Dispensing product 18 Reloading During Service 18 Reloading a Connect 4 Chiller 18 Reloading a Connect 8 Chiller 18 Blanking 18 Operating Freepour After Service 19 Daily Cleaning Rou...

Страница 4: ...ned by a water jet This unit can be used up to an altitude of 2000 meters above sea level The unit is designed to operate in ambient temperatures between 16 C to 38 C If the unit is to be installed wh...

Страница 5: ...ternal configuration you may be able to connect all bladders loaded or as few as one bladder at time IMPORTANT Only approved varieties of milk and fruit juice may be dispensed Approved varieties of mi...

Страница 6: ...lows for a variety of installation configurations to suit your dispense station layout When deciding where each of the three units will be located consider how the machine will be used in service relo...

Страница 7: ...ed to site on standard height castors Short roller style castors can be supplied by request and fitted on site Operation Automatic Start Up Connect the cabinet to the mains power supply and check oper...

Страница 8: ...firmly up to the fitting at the base of the tap Observe the stickers on the protective sleeves showing the tap and Chiller ends of the sleeve 2 Feed insulation over the fluid product lines Fasten in...

Страница 9: ...hanged for example to slow the rate of dispense into an unusual shaped vessel to reduce the chance of overfilling Changing the Dose Time Use the interface on the Control Unit to change the Dose Time 1...

Страница 10: ...g features are not active In the event that the electronics are malfunctioning Freepour can still dispense milk as long as the internal power supply and pumps are still active No dosing and programmin...

Страница 11: ...e Control Unit MENU CLEANING ROUTINE 2 Remove trays with empty bladders Discard empty bladders and wash the trays 3 Remove trays with partially full bladders To prevent bladders leaking from the cap f...

Страница 12: ...setpoint be changed unless it is absolutely necessary and then only by small increments at a time To view and adjust the temperature setpoint 1 Press and hold the set button until the controller displ...

Страница 13: ...or more frequently if required See page 23 for instructions on how to clean the condenser coil IMPORTANT Unplug the cabinet from the power supply before cleaning the condenser coil Over time dust may...

Страница 14: ...shown on screen If the NO CURRENT error is displayed on screen The pump cable may have become disconnected The circuit breaker s may have tripped A pump may be jammed or The pump s may have failed Rec...

Страница 15: ...where this is not permitted If the red caps are being used to in the BLANK orientation on certain connectors in the Chiller small amounts of milk will spray into the Chiller after each dose and Automa...

Страница 16: ......

Страница 17: ...mple Machines we are always looking for ways to improve our products The illustrations in this guide may differ slightly from the actual product Made in Australia D00142 A05 l 2020 SIX SIMPLE MACHINES...

Отзывы: