SR Instruments SR Scales SR725i Скачать руководство пользователя страница 22

Model SR725

i

 Wheelchair Scale 

Operating and Service Manual  
Part No.  MAN725

i

_MICROBAN_200603 

 

Page 22 of 24 

 

S

Instruments, Inc.

600 Young Street, Tonawanda, NY  14150 

Tel: 716-693-5977     Fax: 716-693-5854    URL

www.srscales.com

 

email: 

[email protected]

     

  

Copyright 2020 

S

Instruments, Inc. 

WARRANTY 

 

FOUR YEAR LIMITED WARRANTY 

Each

  S

  system.  is  manufactured  with  high  quality  components.    SR  Instruments,  Inc. 

warrants  that  all  new  equipment  will  be  free  from  defects  in  material  or  workmanship,  under 
normal  use  and  service,  for  a  period  of  four  (4)  years  from  the  date  of  purchase  by  the  original 
purchaser.    Normal  wear  and  tear,  injury  by  natural  forces,  user  neglect,  and  purposeful 
destruction are not covered by this warranty.  Warranty service must be performed by the factory 
or  an  authorized  repair  station.    Service  provided  on  equipment  returned  to  the  factory  or 
authorized repair station includes labor to replace defective parts.  Goods returned must be shipped 
with transportation and/or broker charges prepaid.  SR Instruments, Inc.’s obligation is limited to 
replacement  of  parts  that  have  been  so  returned  and  are  disclosed  to  SR  Instruments,  Inc.’s 
satisfaction  to  be  defective.    The  provisions  of  this  warranty  clause  are  in  lieu  of  all  other 
warranties,  expressed  or  implied,  and  of  all  other  obligations  or  liabilities  on  SR  Instruments, 
Inc.’s part, and it neither assumes nor authorizes any other person to assume for SR Instruments, 
Inc.  any  other  liabilities  in  connection  with  the  sale  of  said  articles.    In  no  event  shall  SR 
Instruments,  Inc.  be  liable  for  any  subsequent  or  special  damages.    Any  misuse,  improper 
installation, or tampering, shall void this warranty. 

 

DAMAGED SHIPMENTS 

Title  passes  to  purchaser  upon  delivery  to  Transportation  Company.    Purchaser  should  file  any 
claims for shortage or damage with  the delivery carrier and should refuse any shipment  that has 
obvious external damage.  

RETURN POLICY 

All products being returned to SR Instruments, Inc. require a Return Goods Authorization number 
(RGA).  To receive an RGA, call our Customer Service at 716-693-5977 ext 103 or toll-free in the 
USA and Canada at 800-654-6360 ext 103. 

When  inquiry  is  made,  please  supply  model  and  serial  numbers,  purchase  order  and  reason  for 
return.  

Generally,  deleted,  damaged,  and  outdated  merchandise  will  not  be  accepted  for  credit.    A 
minimum restocking charge of 15% will be assessed on return of current merchandise unless scale 
is returned because of SR error.  

No returns will be accepted after 30 days. 

All  returns  are  to  be  shipped  FREIGHT  PREPAID  to:    SR  Instruments,  Inc.,  600  Young  Street, 
Tonawanda, NY 14150. 

RESTOCKING FEE 

 

15% fee

 will be assessed on return of current merchandise 

 

No fees

 will be charged if the scale is returned because of an error on the part of SR 

Instruments, Inc. 

 

No returns 

accepted after 30 days

.

  

Содержание SR Scales SR725i

Страница 1: ...AN_200603 Page 1 of 24 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstruments Inc S by S In...

Страница 2: ...N 9 STORAGE AND TRANSPORTATION 10 CLEANING AND DISINFECTING 11 SPECIFICATIONS 12 BUTTON FUNCTIONS 13 BASIC SYSTEM OPERATION 14 BATTERY REPLACEMENT 16 THEORY OF OPERATION 17 CALIBRATION 18 CONFIGURING...

Страница 3: ...20 SInstruments Inc PACKING CHECKLIST Model SR725i Wheelchair Scale System DESCRIPTION QUANTITY Box 1 SCALE ASSEMBLY 32 in x 30 in 81 cm x 76 cm 1 ea PACKAGE OF SIX 6 D CELL BATTERIES 1 ea CALIBRATION...

Страница 4: ...0 SInstruments Inc PACKING CHECKLIST Model SR725i L Wheelchair Scale System DESCRIPTION QUANTITY Box 1 SCALE ASSEMBLY 36 in x 30 in 91 cm x 76 cm 1 ea PACKAGE OF SIX 6 D CELL BATTERIES 1 ea CALIBRATIO...

Страница 5: ...Diagram Figure 2 Parts Identification List STEP 3 Figure 1 Lay the scale on the floor with the feet on the floor STEP 4 Adjust leveling feet located in each of the four corners of the underside of the...

Страница 6: ...r bumper from the display base Figure 3 Rotate the display 180 degrees Re insert mounting screw and rubber bumper and tighten Note To provide correct alignment and to secure the display to the mast pr...

Страница 7: ...the top of the Mast Tighten the two 2 set screws to secure the Printer Mounting Collar to the Mast NOTE The three 3 holes on the Printer Mounting Collar should be towards the top of the Mast facing th...

Страница 8: ...om email sri srinstruments com Copyright 2020 SInstruments Inc REPLACEMENT PARTS and ACCESSORIES Part Description SR8219 Printer Kit optional contains all printer parts listed below FRAP1300 Printer F...

Страница 9: ...p to 400 hours of weight readings before needing replacement This eliminates the need for an external battery charger or the danger of an AC power supply cord on a portable scale The patient s weight...

Страница 10: ...ns should not vary outside the following conditions Relative Humidity 0 to 85 Ambient Temperature 14 F to 122 F 10 C to 50 C TRANSPORTATION To transport the scale pull up on the Snap Lock Figure 7 Fol...

Страница 11: ...eas Use a soft cloth dampened with disinfectant or a damp disposable disinfectant cloth Cloth cannot be dripping wet Follow manufacturer s instruction on the proper use of commercially available disin...

Страница 12: ...ge AUTO ZERO One button operation AUTO POWER DOWN Approximately 30 seconds adjustable to 300 seconds ENTER Stores displayed reading in memory RECALL Recalls last stored stable weight height and BMI AV...

Страница 13: ...en stable Auto stores stable weight in memory SEND PRINTER EHR Press to send stored values to EHR or to printer Output values include time date weight height and BMI Also indicated on display when pap...

Страница 14: ...selected digit when setting time and date BASIC SYSTEM OPERATION SETTING SYSTEM ZERO Make sure the scale is free and clear of any obstructions and press and hold the ZERO WEIGH button The displayed me...

Страница 15: ...5 in Use the UP or DOWN arrows to adjust the default height to the value of the patient s height NOTE To calculate the BMI a patient s stable weight needs be stored as indicated in WEIGHING above if n...

Страница 16: ...he panel screw on the Battery Compartment Cover 13 and remove the battery compartment cover STEP 3 Remove and replace ALL six 6 D cell batteries Refer to diagram in the battery compartment for placeme...

Страница 17: ...rs serving to normalize the sensitivity voltage out per unit of weight applied of each bridge The offset potentiometer produces a small current which nulls the output of the amplifier for an unloaded...

Страница 18: ...second weight should be less than half of the first weight DO NOT USE barbells or un calibrated weights STEP 2 Zero the scale by pressing and holding ZERO WEIGH button STEP 3 Place the first calibrate...

Страница 19: ...f the first weight DO NOT USE barbells or uncalibrated weights STEP 3 Press the MENU button until FULL 1000 00 Lb is displayed Set the FULL value of the first selected calibrated weight Use the UP arr...

Страница 20: ...ING SEND BUTTON STEP 1 Press the MENU key until DATA OUT PRINT is displayed STEP 2 Press UP or DOWN key to select between EHR and PRINT STEP 3 Press the ENTER key to save EHR OUTPUT Electronic Medical...

Страница 21: ...k but do not respond to button activation Check to ensure the membrane switch label is correctly plugged into display board Check to ensure the calibration switch is not in the Calibration Mode Figure...

Страница 22: ...iabilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no...

Страница 23: ...and Service Manual Part No MAN725i_MICROBAN_200603 Page 23 of 24 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments co...

Страница 24: ...MAN725i_MICROBAN_200603 Page 24 of 24 SInstruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2020 SInstrument...