Safety
(menu option)
From the initial menu screen select Safety using the Plus and Minus button and press Enter.
Safety:
This setting determines what course of action will take place during an error condition. This also controls the
built in safety relay. Once the error condition is corrected the device will return to normal operations.
INDIVIDUAL OUTPUTS:
This option is the default setting and does not enable the built in safety relay. During an error condition it turns
off the output that has the error. High/Low alarms will not shut off the output.
INDIVIDUAL OUTPUTS: Include High / Low
This option does not enable the
built in safety relay. During an error condition it turns off the output that has
the error. High/Low alarms will shut off the output that is out of range.
ALL OUTPUTS: Any Error
This option enables the built in safety relay. If any error condition occurs all outputs will be turned off and the
safety relay is triggered, which cuts the main power to all the outputs.
ALL OUTPUTS: High/Low Error
This option enables the built in
safety relay. If any High/Low alarm condition is set and is breached all outputs
will be turned off and the safety relay is triggered, which cuts the main power to all the outputs.
ALL OUTPUTS: Low Alarm Error
This option enables the built in safety relay. If any Low alarm condition is set and is breached all outputs will be
turned off and the safety relay is triggered, which cuts the main power to all the outputs.
ALL OUTPUTS: High Alarm Error
This option enables the built in safety relay. If any
High alarm condition is set and is breached all outputs will
be turned off and the safety relay is triggered, which cuts the main power to all the outputs.