d. Apply grease again. Slip bearing cup over roller
assembly. Install both inner and outer spacers.
Place remaining cup onto outer spacer and press on
the remaining cone and roller assembly. (See Table
4 on Page 35.)
Be sure outer spacer is concentric on shaft.
Gear Case Assembly
1. Shaft Installatlon
Front Bearing Grease Seals
-
5080 only
a. Place bearing gear case on arbor press. Install
front bearing grease seals, with lip towards center of
cavity, flush with back face of bore.
b. Coat lip seals with grease.
ROLLER
CUP
SPACERS
CUP
ROLLER
5080 ONLY
Shims - ALL MODELS
c. To determine the shim thickness required for the
front bearing, measure dimension "
A
" in the gear
case and dimension "
B
" on the shaft to three
decimal places (1.000, for example).
Using these values to calculate the shim thickness
as follows:
Dimension "
A
" minus dimension "
B
" = required
shim thickness.
d. Use standard shim packs to equal the required
shim thickness. Place against shoulder in front
bearing bore. (Also see Page 35.)
(SUGGESTED SHIMS)
FLUSH
GREASE
GEAR CASE
FRONT FACE
SHIM
RECONDITIONED
SHAFT
Model OLD SHAFT NEW SHAFT
R1
R2
.090
.090
INSTALL SHAFTS
Install shaft assemblies in gear case with spline
end up and the drive shaft in proper location to give
top or bottom drive as required. Press shafts into
gear case until seated against shim pack.
95-03012
29
.116 - .120
.110
ALL
12-18-2015
12-18-15
5080 ONLY
Содержание Universal 5000 Industrial Series
Страница 6: ...4 95 03012 SECTION II INSTALLATION...
Страница 40: ...38 95 03012 5040 UNIVERSAL INDUSTRIAL PUMP SECTION XII UNIVERSAL INDUSTRIAL PARTS LIST 5040 2 17 99...
Страница 42: ...40 95 03012 5050 UNIVERSAL INDUSTRIAL PUMP 5050 2 17 99...
Страница 44: ...42 95 03012 5060 UNIVERSAL INDUSTRIAL PUMP 5060 2 17 99...
Страница 46: ...44 95 03012 5070 UNIVERSAL INDUSTRIAL PUMP 5070 2 17 99...
Страница 48: ...46 95 03012 5080 UNIVERSAL INDUSTRIAL PUMP 5080 2 17 99...
Страница 55: ...95 03012 53...
Страница 57: ......