![SPX S2045 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/spx/s2045/s2045_instruction-manual_1352686028.webp)
Operation
Waukesha Cherry-Burrell
Page 28
95-03080
12/2010
Operation
Before proceeding, make sure your pump has been correctly
installed as described in “Installation” on page 23.
Starting the Pump
1.
If pump has a flush seal option, start the flow of flush water
(approximately 5 US gallons per hour recommended rate)
before operating the pump.
2.
Prime the pump by flooding the pump casing with liquid
BEFORE
starting the pump to avoid damage to pump parts.
See “Priming the Pump With the Feed Source Above Pump
Level” on page 28 or “Priming the Pump With the Feed
Source Below Pump Level” on page 29.
3.
Start the pump motor and check the motor rotation to make
sure it is in the same direction as the arrow on the pump.
4.
Check the pump to see that liquid is flowing and that all piping
connections and seals are leak-free.
5.
Make sure that the pump is not operating against a closed
discharge. Continued operation against a closed discharge
will heat the liquid in the casing to boiling and lead to pump
damage.
6.
Slowly open the discharge valve until the desired flow is
obtained. Observe pressure gauges and if pressure is not
attained quickly, stop the pump and prime it again.
Priming the Pump
Priming the Pump With the Feed Source Above
Pump Level
1.
Fill the supply tank with liquid; open the supply line valve
(suction) (item B).
2.
Vent any air trapped in the supply line or casing by opening
the discharge valve. (item A).
3.
Start the pump.
Figure 22 - Pump Below Supply
(Feed Source Above Pump Level)
Содержание S2045
Страница 2: ......
Страница 52: ...Parts Lists Waukesha Cherry Burrell Page 52 95 03080 12 2010 Seal Components All Pumps...
Страница 64: ...Parts Lists Waukesha Cherry Burrell Page 64 95 03080 12 2010 Pedestal Mounted Pumps Small Bore...
Страница 66: ...Parts Lists Waukesha Cherry Burrell Page 66 95 03080 12 2010 Pedestal Mounted Pumps Small Bore cont d...
Страница 68: ...Parts Lists Waukesha Cherry Burrell Page 68 95 03080 12 2010 Pedestal Mounted Pumps Large Bore...
Страница 70: ...Parts Lists Waukesha Cherry Burrell Page 70 95 03080 12 2010 Pedestal Mounted Pumps Large Bore cont d...
Страница 76: ...Troubleshooting Waukesha Cherry Burrell Page 76 95 03080 12 2010 Notes...
Страница 77: ......