Display features

14

15

25

16

20

21

24

Name

Information and use

14

Date

Provides date information to stored files

15

Cursor 1

Position for accurate measurement to discontinuities

16

Cursor 2

Position for accurate measurement to discontinuities

17

Launch pulse

The pulse sent out by the TDR

18

Reflected pulse(s)

Pulse(s) reflected by a cable discontinuity

19

Time measurement

Time for the pulse to reach the discontinuity

20

Distance measurement

Distance along the cable to the discontinuity

21

dBRL measurements

dB of Return Loss at cursor 1 and 2

22

WAVE

form submenu

Use, with the arrow keys, to Zoom and Move 
waveforms

23

CUR

sor submenu

Select cursor 1 or 2. Move cursors with left and right 
arrow keys

24

C

on

F

i

G

uration 

submenu

Change selected parameter with arrow keys

25

Time

Provides time information to stored files

26

Battery status

Shows battery charge

17

18

19

23

22

Содержание RADIODETECTION 1205CXB

Страница 1: ...1205CXB Time Domain Reflectometer and Cable Analyser User Guide 90 1205CXB UG ENG 02...

Страница 2: ......

Страница 3: ...place after this user manual was published Contact your local Radiodetection dealer or visit www radiodetection com for the latest information about the 1205CXB product family including this guide CA...

Страница 4: ...g documentation the safety of the operator may be compromised Do not expose the equipment to extreme temperatures Store the instrument indoors during extreme hot or cold temperatures and bring the ins...

Страница 5: ...able must contain at least two conductors or one conductor and screen This can be generalized to include other multi conductor set ups such as district heating systems Velocity of Propagation VOP The...

Страница 6: ...Select cursor 1 or 2 7 WAVEform Select move or zoom function for a waveform 8 MENU Select units a pre loaded cable and system settings 9 SAVE Save waveform to 1205CXB s memory or USB 10 LOAD Load a w...

Страница 7: ...able discontinuity 19 Time measurement Time for the pulse to reach the discontinuity 20 Distance measurement Distance along the cable to the discontinuity 21 dBRL measurements dB of Return Loss at cur...

Страница 8: ...cable from memory and saving and recalling waveforms can be accessed via the MENU button 8 For details please refer to the 1205CXB Operation Manual 9 Press the Power button 4 to turn 1205CXB off Wavef...

Страница 9: ...However you can extend your equipment s life by following these care and maintenance guidelines Store the equipment in a clean and dry environment Ensure connection sockets are clean free of debris an...

Страница 10: ...itted modified or used in whole or in part without the prior written consent of Radiodetection Ltd Visit www radiodetection com Follow us on USA Raymond ME Kearneysville WV Canada Vaughan ON Mississau...

Отзывы: