background image

Function buttons

1

TEMP DOWN Button    

 

Push this button to decrease set temperature, in
increments of 2°F (1°C). Lowest is 62°F (17°C°)

2

TEMP UP Button    

 

Push this button to increase set temperature, in 
increments of 2°F (1°C). Highest 88°F (30°C°)

 Each time the button is pressed, the operation 
 mode is selected in the following sequence:   
  

3

MODE  Button    

 

TEMP

AUTO 
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

MODE

FAN SPEED

SWING

TIMER ON

ECONOMY

ON/OFF

TIMER OFF

RESET LOCK

1

2

4

3

6

5

7

8

9

10

11

SET TEMPERATURE(   C)

        LED
    DISPLAY

4

SWING Button

Press to start/stop auto swing feature. Or to set
desired angle for directional airflow.

5

6

RESET Button    

 

If the recessed RESET button is pressed, all 
current settings will be cancelled and the
controller will return to the default settings.

7

ON/OFF Button    

 

Power button, press to turn unit ON/OFF.

NOTE:  

Heat mode is for Cooling & Heating  models only.

AUTO

COOL

DRY

HEAT

FAN 

 

Press to select the fan speed in four steps: 

    Auto     Low     Med     High

FAN SPEED Button    

 

12

TIMER ON Button    

 

8

Press to activate Auto-on timer. Each press
increases the timer setting by 30-minutes, up
to 10 hours. Then at 1-hour increments, up 
to 24 hours. To cancel the Auto-on timer, press
the button until time setting is 0.0.

9

ECONOMY(SLEEP) Button    

 

Press to engage Sleep mode. Select this
function for the sleeping hours to maintain the
most comfortable temperature and save energy.
This function is only available under AUTO,
COOL and HEAT (heating models) modes.

NOTE: 

SLEEP function would be cancelled if 

ON/OFF, FAN SPEED, SLEEP or MODE button
is pressed.

HANDLING  THE  REMOTE  CONTROLLER

17

TIMRT OFF Button    

 

LOCK Button    

 

10

11

Press this recessed button to lock all current 
settings (a lock symbol will appear on the LCD).
When the remote is locked, it will not respond 
to any actions except LOCK. Use the LOCK
mode when you want to prevent any accidental
setting changes. Press again to unlock

Press this button to turn off the display on the 
unit, press it again to light the display .

LED Display Button    

 

12

Press to activate Auto-off timer. Each press
increases the timer setting by 30-minutes, up
to 10 hours. Then at 1-hour increments, up 
to 24 hours. To cancel the Auto-off timer, press
the button until time setting is 0.0.

Содержание WA-1240AE

Страница 1: ...WA 1240AE 12 000 BTU Cooling only...

Страница 2: ...ies 4 Names of parts 5 Electronic control operating instructions 6 Operating instructions 7 Location 9 Window kit installation 9 Exhaust hose installation 12 Though the wall connection 12 Water draina...

Страница 3: ...t least free of charge to the user C As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your health when haza...

Страница 4: ...und the unit for proper airflow from walls furniture and curtains If the unit is knocked over during use turn off power immediately and unplug from power source Never leave the unit unsupervised when...

Страница 5: ...any other appliance Avoid fire hazard or electric shock Do not use an extension cord or an adaptor plug Do not remove any prong from the power cord WARNING Electrical Information IDENTIFICATION OF PA...

Страница 6: ...11 Upper air intake 12 Fig 1 13 1 2 4 Fig 2 5 7 9 8 15 14 13 12 5 Upper air filter Behind the grille 6 10 11 Air outlet Heating models only Power cord outlet Power cord bracket for storage purposes on...

Страница 7: ...AN and HEAT heating models only The corresponding mode indicator light will illuminate MODE select button Power switch press to turn on off POWER button 2 UP and DOWN button 6 TIMER button Used to ini...

Страница 8: ...e auto stop program the TIMER OFF indicator light will illuminate Press the or buttons to set the time for unit to turn off Press the TIMER button again within 5 seconds will initiate the auto start p...

Страница 9: ...nd down Press SWING button again at desired angle for set air flow Please do not adjust the louver manually Air flow direction adjustment Swing automatically If unit is running in COOL mode when SLEEP...

Страница 10: ...wall for efficient air conditioning Your window slider kit has been designed to fit most standard vertical and horizontal window applications However it may be necessary for you to improvise or modif...

Страница 11: ...lider kit to window stool on top of foam seal Fig 9 3 Trim another foam seal with adhesive to the proper length and place on top of the slider kit Fig 10 4 Close the window sash securely against the k...

Страница 12: ...3 3 Trim another foam seal with adhesive to the proper length and attach it to the open side of slider kit Fig 14 4 Slide window close against the slider kit 5 Trim the last foam seal to the proper le...

Страница 13: ...ugh the wall connection NOTE It is necessary to purchase the following parts for through the wall installation IMPORTANT DO NOT OVER BEND THE EXHAUST HOSE SEE Fig 19 The exhaust hose can be compressed...

Страница 14: ......

Страница 15: ...filters and allow to dry completely in a shady area do not place under direct sunlight Mounting Replace upper filter according to arrow direction in Fig 24 Replace lower filter and reinsert the screw...

Страница 16: ...The windows or doors in the room are not closed There are heat sources inside the room Exhaust air duct is not connected or blocked Temperature setting is too high Air filters are dirty 2 Not cool eno...

Страница 17: ...and ends correctly 3 Replace cover by sliding it back into position NOTE When the batteries are removed any programming will be erased After inserting the new batteries the remote controller can be re...

Страница 18: ...activate Auto on timer Each press increases the timer setting by 30 minutes up to 10 hours Then at 1 hour increments up to 24 hours To cancel the Auto on timer press the button until time setting is...

Страница 19: ...no display This indicator will be displayed when the unit is operating Indicates the selected fan speed AUTO HIGH MED or LOW AUTO fan speed will have no indicator displayed When unit is operating in A...

Страница 20: ...AUTO COOL DRY HEAT FAN HIGH MED LOW MODE FAN SPEED SWING TIMER ON ECONOMY ON OFF TIMER OFF RESET LOCK SET TEMPERATURE C LED DISPLAY 3 1 2 TEMP AUTO COOL DRY HEAT FAN HIGH MED LOW MODE FAN SPEED SWING...

Страница 21: ...isplayed 2 Press the TIMER OFF button again to begin setting the desire time Each press of the button increases the time by 30 minutes up to 10 hours Then by 1 hour increments up to 24 hours After set...

Страница 22: ...is useful when you want the unit to start before you wake up and stop after you leave the house Example To start the AC unit in 2 hours and stop after 5 hours 1 Press the TIMER ON button to initiate a...

Страница 23: ...cement parts will be new or reconditioned Parts which are replaced become the property of Sunpentown The warranty applies for the use of the product in the USA only What is NOT COVERED Warranty does n...

Страница 24: ......

Отзывы: