Features: 

 

Stainless Steel front panel and flat door 

 

LED indicators on operation board 

 

Internal water storage tank for water preservation 

 

Insulated ice storage cabinet 

 

Gravity based draining 

 

Auto-cleaning function: Every time the unit is turned on, it will go through an auto-cleaning 

process. During this process, the 3 indicator lights (“RUN”, “FAULT” and “WATER LOW”) will 

flash at the same time. This process takes about one minute 

 

Overheat protection: If the internal temperature is above 164°F, the unit will shut-off 

automatically with “FAULT” and “WATER LOW” lights flashing and the “RUN” light staying solid. 

The unit will resume operation when the internal temperature drops below 158°F. 

 

Before First Use: 

1.

 

The unit should not be tilted more than 45° during transportation and unpacking. Do not turn 

the ice maker upside-down as this may damage the compressor or refrigeration system.   

2.

 

The flake ice maker should be placed on a flat, level and firm surface away from any heat 

sources or corrosive gas.  

3.

 

This unit is for Free-Standing use only. It vents from the sides. Do no place anything above the 

unit or install under-counter. There must be at least 3 feet of clearance on each side and at least 

6-inches behind the unit.  

4.

 

Wait 12 hours after installation before turning on the ice maker. 

5.

 

Unit is designed for use in a 3-prong grounded outlet. Do not use adapters to bypass this 

feature. 

6.

 

If the power cord is damage, it must be replaced by a qualified person to avoid electrical 

hazards. 

7.

 

Flake ice maker should be connected to a drinkable water supply only. 

8.

 

This appliance is not intended for use by children or other persons without assistance or 

supervision if their physical, sensory or mental capabilities prevent them from using it safely. 

Children should be supervised to ensure that they do not play with the appliance. 

1

.

.

9.

 

Please do not place the machine near flammable materials. 

10.

 

Use only new hose sets with the appliance. Do not use previously used hoses. 

Содержание SZB-20

Страница 1: ...Automatic Flake Ice Maker Instruction Manual SZB 20 SZB 40 Thank you for selecting SPT Automatic Flake Ice Maker Please follow and save this instruction manual ...

Страница 2: ...Content Features 1 Before First Use 1 Structure 2 Accessories 2 Installation Instructions 3 Maintenance 3 Specifications 3 Troubleshooting 4 Circuit Diagram 5 Warranty ...

Страница 3: ...flake ice maker should be placed on a flat level and firm surface away from any heat sources or corrosive gas 3 This unit is for Free Standing use only It vents from the sides Do no place anything above the unit or install under counter There must be at least 3 feet of clearance on each side and at least 6 inches behind the unit 4 Wait 12 hours after installation before turning on the ice maker 5 ...

Страница 4: ...Display Panel 3 Ice Maker Door 4 Ice Outlet 5 Ice Full Sensor 6 Ice Storage Cabinet 7 Power Cord 8 Water Inlet 9 Drain Spout 10 Drain Outlet 11 Foot Accessories Water Inlet Tube Water Drainage Tube 2 Squeeze Hose Clamp Ice Shovel ...

Страница 5: ...SI 5 Insert the plug into the power supply socket Maintenance 1 If the compressor stops for any reason like water shortage ice full power off or loss of power do not restart it right away Please wait about 5 minutes 2 Check the water inlet and drain line connectors regularly for any signs of cracks or wear 3 If the ice maker will be unused for a long period of time please switch off the power swit...

Страница 6: ...ks but no ice is made 1 Refrigerant leakage 2 The refrigeration system is blocked 1 Contact refrigerator repair shops for recharging refrigerant 2 Check whether the ventilation fan is working FAULT indicator light stays on 1 Flake ice motor is damaged 2 Fan motor is damaged Contact Sunpentown ICE FULL indicator light flashes The ice full sensor is loose or damaged Replace the ice full sensor WATER...

Страница 7: ...Circuit Diagram 5 ...

Страница 8: ...ll not be extended beyond the original one year period All replacement parts will be new or reconditioned Parts which are replaced become the property of Sunpentown The warranty applies for the use of the product in the USA only What is NOT COVERED Warranty does not include freight charges Incidental or consequential damage caused by possible defects with this product Damage to product caused by i...