Troubleshooting:
Trouble
Causes
Solutions
The ice maker does not work.
1.
The voltage is too low.
2.
The ambient
temperature is too
low (lower than 41°F)
1.
Turn off the ice maker
and restart it when the
voltage is normal.
2.
Use it when the ambient
temperature is higher
than 41°F.
“WATER LOW” indicator light is
on.
1.
Water shortage from
the water supply.
2.
Water valve is
damaged.
3.
Water pressure is too
low.
1.
Check the water supply.
2.
Check the water valve.
3.
Water pressure should be
higher than 1.5 bar.
Compressor does not work.
1.
Water shortage.
2.
Ice is full.
1.
Check the water supply
system, including water
valve and water tubes.
2.
Remove the ice from the
ice bucket.
Compressor works, but no ice is
made.
1.
Refrigerant leakage.
2.
The refrigeration
system is blocked.
1.
Contact refrigerator
repair shops for
recharging refrigerant.
2.
Check whether the
ventilation fan is working.
“FAULT” indicator light stays
on.
1.
Flake ice motor is
damaged.
2.
Fan motor is
damaged.
Contact Sunpentown.
“ICE FULL” indicator light
flashes.
The ice full sensor is loose or
damaged.
Replace the ice full sensor.
“WATER LOW” and “ICE FULL”
indicator lights flashes at the
same time.
1.
Water inlet is clogged.
2.
Ambient temperature
is too low.
Turn off the unit and turn it back
on when the ambient
temperature is high than 41°F.
“FAULT” and “WATER LOW”
lights flash and the “RUN” light
stays solid.
The unit is overheated.
The internal temperature is above
164°F. The unit will resume
operation when the internal
temperature drops below 158°F.
Please contact Sunpentown if the troubleshooting doesn’t work