background image

IMPORTANT! 

The carbon media inside the filter system MUST soak in water for a minimum of 

48 hours prior to installation

Carbon Soak Instructions (48 Hours Prior)

Carbon Filter 

Tank (Tank 2)

Softener Tank 

(FS)

Bypass Valves 

(x2)

MNPT Fittings 

(x4)

Hose Bib 

Assembly

Lawn Hose 

Connected to Faucet

This step will require the materials listed below

10) Insert the bypass valve onto 
the top of each tank.

11) Fully tighten the fasteners 
on both valve connections 
securing the bypass valves.

12) Attach and tighten a MNPT 
Fitting onto the connections on 
each of the bypass valves.

13) Use the hose bib to attach 
the lawn hose to the inlet on the 
first tank. Ensure the bypass is 
off to allow water flow through 
the tank.

14) Turn on the water to the 
hose halfway until water 
exits the tank. Turn off the 
water and disconnect the 
hose and hose bib.

15) Switch the tank to bypass  
and store for 48 hours. 

Repeat steps 10-14 with both 
tanks.

Bypass Operation

Bypass on, water does 

not flow through tank

Bypass off, water 

flows through tank

Questions? Call (800)-589-5592

7

Ultra Whole House Well Water Filter System Combo

Содержание ULTRA UWS1

Страница 1: ...ich uses the highest quality coconut shell catalytic carbon that targets the contaminants that we find in our water supplies today ULTRA Whole House Well Water Filter System Combo Model UWS1 UWS4 This is the ultimate combo system for anyone who has high levels of iron manganese and hydrogen sulfide We ve combined our whole house well system with our whole house carbon filtration system and salt fr...

Страница 2: ... Tank 1 Tank 2 1 inch 24 inch Long Corrugated Water Connectors x5 1 inch 3 inch long PVC Nipple x3 1 Roll Plumbers Tape 1 inch threaded connectors for pre plumb slip threaded elbows shown 1 Inch PVC Shut Off Valve Zip Ties Electronic Head for Well Water Filter Tank 1 Carbon Filter Tank Softening Tank Pre Filter Spanner Wrench Mounting Bracket Gasket and Lube Sediment Filter Tank Head for Carbon Fi...

Страница 3: ...sure to follow all applicable plumbing codes The system must be installed on a main water supply line System Configuration Water Source From Your Well 2 The sediment filter eliminates any particulate 1 The Well Water Filter uses an air injecting oxidation filter to remove iron sulfur and manganese from your water 4 The Softener will neutralize any remaining particulate 1 2 4 Filtered and Softened ...

Страница 4: ...Range 6 8 10 System Specifications CF1 Tank Width 9 Tank Height 48 52 with Head Flow Rate 9 GPM Service Connection Size 1 Operating Pressure 25 80 PSI Operating Temperatures 36 120 F Pre Filter Change Replacement Every 6 9 Months Media Change Replacement Every 6 years or 1 Million Gallons CF4 Tank Width 10 Tank Height 54 58 with Head Flow Rate 11 GPM Service Connection Size 1 Operating Pressure 25...

Страница 5: ...onnection Size 1 Max Pressure 75 PSI Operating Temperatures 35 110 F Questions Call 800 589 5592 5 FS4 Tank Width 9 Tank Height 48 52 with Head Flow Rate 15 GPM Service Connection Size 1 Max Pressure 75 PSI Operating Temperatures 35 110 F Ultra Whole House Well Water Filter System Combo ...

Страница 6: ...tions Call 800 589 5592 6 ONCE THE HEAD ATTACHES TO THE PIPE INSIDE THE TANK IT IS PERMANENT Do not attempt to unscrew or remove the head from the tank or it will cause the components within the tank to separate causing damage and potentially cause resin to seep from the tank into your home plumbing 1 Unscrew the cap on top of the carbon filter tank 8 Use your feet around the boot to add grip to t...

Страница 7: ...ions securing the bypass valves 12 Attach and tighten a MNPT Fitting onto the connections on each of the bypass valves 13 Use the hose bib to attach the lawn hose to the inlet on the first tank Ensure the bypass is off to allow water flow through the tank 14 Turn on the water to the hose halfway until water exits the tank Turn off the water and disconnect the hose and hose bib 15 Switch the tank t...

Страница 8: ...ur pre soak 17 Attach the hose bib assembly onto the inlet port on the tank 18 Connect the hose to the hose bib assembly 19 Run water through the tank until the water runs clear 20 Switch the hose and hose bib to the outlet side now and flush with water in the opposite direction until the water runs clear 21 Repeats steps 16 through 20 on both tanks Bypass Operation Bypass on water does not flow t...

Страница 9: ...ded 24 Locate the opening at the bottom of the well water filter electronic head 25 Align the opening on the bottom of the tank head with the pipe inside the tank 26 Press the tank head down to allow the threads to catch 27 Turn the tank head clockwise until it is fully tightened Tank 1 Note If your tank was shipped with a jacket it can be zipped around the tank prior to or after the installation ...

Страница 10: ...curing the bypass valve 28 Install a bypass valve onto the connections on the electronic head 31 Attach and tighten a MNPT Fitting onto each of the connections on the bypass valve 32 Apply plumbers tape to both MNPT Fittings Questions Call 800 589 5592 10 Installing the Well Water Filter Electronic Head Ultra Whole House Well Water Filter System Combo ...

Страница 11: ...he top of the pre filter Housing tank 35 Squeeze lubricant onto the O ring then spread it using your finger 36 Flip the O Ring over and lubricate the opposite side as well 38 Replace the lid and fully tighten it Note If the tanks have a stainless steel sleeve that is covered in protective plastic Please remove the plastic prior to install The sleeves can be maintained and polished using automobile...

Страница 12: ... pre plumb into the inlet of the pre filter Mark your holes for pre drilling 42 Use a 3 16 drill bit to pre drill the holes for the pre filter mounting bracket 43 Use 4 of the provided bolts and washers to secure the bracket to the wall using a 1 2 socket Spanner Wrench Mounting Bracket 1 inch 3 inch long PVC Nipples x3 Plumbers Tape 1 Inch PVC Shut Off Valve Wrench and Pliers 44 Before mounting t...

Страница 13: ...ead when connecting all corrugated pipes 48 Connect the PVC shut off valve onto the threaded adapter on the incoming water supply Questions Call 800 589 5592 13 IMPORTANT Be sure to turn off the water main to your home before proceeding to the next steps 49 Apply plumbers tape to the third PVC nipple Installing the Tanks Part 1 Well Water Filter Tank This step will require the materials listed bel...

Страница 14: ...f the well water filter Ensure it is fully tightened Installing the Drain Line Well Water Filter 55 Remove the blue lock tab securing the drain valve in place 56 Pull the drain valve straight out 57 Slide a hose clamp over an end of one of the provided drain lines This step will require the materials listed below 54 Locate the drain valve on the left side of the well water filter head It is a comp...

Страница 15: ... line isn t pinched 62 Insert the blue tab to lock the drain valve back in position 63 Thread the drain line towards your drain and cut away the excess leaving some slack 64 To ensure the drain line doesn t come out from the drain a pair of zip ties are recommended They can be inserted through two pairs of holes drilled high up in the drainpipe 65 Pushing the zip ties inwards will create a loop 66...

Страница 16: ...of the pre filter 70 Connect the other end to the inlet on the softening tank Note The inlet and outlet on this tank are opposite the well water filter This step will require the materials listed below Questions Call 800 589 5592 16 72 Position the softening tank next to the carbon filter tank Carbon Filter Tank 2 Tank 2 Plumbers Tape Wrench 1 inch 24 inch Long Corrugated Water Connectors x4 Note ...

Страница 17: ...ack into the home Be sure to fully tighten 73 Bend the corrugated connector from the output side of the carbon filter towards the input side on the softening tank Thread and fully tighten Questions Call 800 589 5592 17 Your system is now fully connected and should be plumbed like this Water From Well Water Into Home 1 Well Water Filter 2 Pre Filter 3 Carbon Filter 4 Water Softener Ultra Whole Hous...

Страница 18: ... connection on the far left beneath the electronic tank head 77 The power adapter will then be plugged into a power supply that isn t controlled by a switch 78 Lift off the cover on the electronic head 79 Locate the batter connection beneath the display Connect a 9v battery then store it in the tray 80 Replace the tank head cover You are ready to test the system Ultra Whole House Well Water Filter...

Страница 19: ...d open the shut off valve to allow water flow through the tank bypasses 89 Allow water to run through the system for 10 minutes It is normal to see a small amount of sediment during this time Questions Call 800 589 5592 19 Off Bypass Bypass 85 Turn on the water to the home and inspect the shut off valve for any leaks 87 If no leaks are detected from the bypass turn off the bypass to the well water...

Страница 20: ...ile Device 91 Open the app and select the Aeration Filter 92 Tap Time of Day on Unit to change the time 93 Select OK to set the time on to the same time as your mobile device 94 The tank should regen while water is not used in the home 95 Tap on the time tile then change the value to 2 00 am Hit OK 96 Tap Filter Backwash Frequency 97 Change the frequency to 5 days Hit OK Well Water Filter Tank Alr...

Страница 21: ...9 Select Advanced Settings 100 Tap Air Charge Frequency 101 Change the value to 1 day 102 Tap Backwash 103 Change the value to 10 min 105 Set the value to 0 min 106 Select Air Draw 107 Set the value to 20 min 108 Select Rapid Rinse 109 Set the value to 5 min 104 Tap Rest Ultra Whole House Well Water Filter System Combo ...

Страница 22: ...inutes You will not be able to use water to the home during this time 112 If you are ready select OK on the regenerate confirmation 111 Select Regenerate Now 110 Tap the Menu Icon Once the regenerations on the tank is completed the system is ready to use Ultra Whole House Well Water Filter System Combo ...

Страница 23: ...h or that the O ring became bunched Slowly unthread the head from the tank approx half a rotation You only need to expose a small gap between the tank collar and the tank head Reconnect the tank to the system and proceed back to page 12 to test the system again Questions Call 800 589 5592 23 Fully re tighten the head onto the tank The O ring will now be able to reseat Ultra Whole House Well Water ...

Отзывы: