844-E Sprayer Control

User program tip

User Programmable Tip

Default = 

0.00

While in the User Programmable Tip step, the tip indicator arrow 

 

will be flashing above the 

P

 tab at the bottom of the display. 

In some cases you may find that nozzles other than those pre-

programmed for the 844 Sprayer Control will need to be used. If 

one of the eleven pre-programmed tips do not meet your needs, this 

programming step allows the user to manually program a tip. 
Use the Plus key   or Minus key 

 to adjust flow rate in US 

Gallons Per Minute (Liters Per Minute) {Imperial Gallons Per Minute} 

at 40 psi (2 bar). Pressing the Plus key   and Minus key   

simultaneously will clear the value to zero. To accept the value, press 

the Program key   to advance to the next programming step. 

The flow rate information for the tip is only used to calculate the 

pressure reading for flow based controls. With non-linear tips, the 

calculation would be incorrect. Therefore we recommend a “

0.00

” 

setting for non-linear tips so that the pressure will read “

0

” at all times, 

instead of an inaccurate pressure. Non linear tips should not be used 

with pressure based controls. Pressure based controls use the tip flow 

rate information to adjust the pressure to achieve the right application 

rate based on the size of the tips. With non linear tips, there is no way 

for the controller to accurately calculate what the pressure should be at 

various speeds.

WARNINg:  If the user is using tips other than the TeeJet®‚ VisiFlo® 

brand, the corresponding colors may not match. In this 

case, the user should determine the flow rate of the tip 

being used at 40 psi (2 bar), and enter this flow rate as the 

programmable tip. 

NOTE:  The flow rate will be automatically displayed at 40 psi (2 bar). 

This pressure must be used for determining your tip’s flow rate. 

Actual operation pressure is not important. 

When the correct nozzle flow rate has been entered, advance to the 

next programming step by pressing the Program key  .

pressure regulation

Pressure Regulation Mode

Default = 

byp

 (By-pass for 

US

trF

I

N

P

, and 

Si

 Modes)

Default = 

thr

 (Throttling for 

nh3

 Mode)

While in the Pressure Regulating Mode step, the regulator symbol 

 

will be flashing at the top of the console display. 

This step tells the 844 where the regulating valve has been plumbed. 

Once set correctly, this value should not change unless the regulating 

valve is physically moved to a new point in the plumbing. For more 

information on plumbing refer to pages 2 and 3 of this manual. 
The default value “

bYP

” indicates that the pressure regulating valve 

is plumbed in the bypass line. In most situations, especially total flows 

below 4 US GPM (15 l/min) {3.3 Imperial GPM}, this is the preferred 

installation position. If the default is correct, press the Program key   

to accept the value and advance to the next step.

NOTE:  When programmed in the bypass mode, with the controller in 

“MAN” mode, the pressure regulating valve should close when 

the Plus key   is pressed, and open when the Minus key   

is pressed. 

The pressure regulating valve can be located in the supply line 

between the flow meter and the boom control valves. If you will be 

locating the pressure regulating valve in this position, use the Plus key 

 or Minus key   to change the value to 

tHr

 (Throttling Mode). 

By doing this, you have reversed the polarity that the console uses to 

control the regulating valve.

NOTE:  When programmed in the throttling mode with the controller 

in “MAN” mode, the valve should open when the Plus key 

 

is pressed and close when the Minus key 

 

is pressed.

Press the Program key   to advance to the next step.

Содержание TeeJet 844-E

Страница 1: ...844 E Sprayer Control User MANUAL Installation Programming and Operating...

Страница 2: ...Mounting The TeeJet 844 Console 7 Console Step 1 Location 7 Console Step 2 Mounting 7 Console Step 3 Power Connection 8 Console Step 4 Connecting Component Cables 9 Connect Step 1 Wiring Layout 10 Co...

Страница 3: ...Counter 19 Simulated Ground Speed 19 Program Specific Gravity 19 Liquid Specific Gravity Density 19 Communications 20 Minimum Pressure 20 Minimum Regulating Pressure Setting 20 Application Setup Mode...

Страница 4: ...EITHER EXPRESSED OR IMPLIED NO COPYRIGHT LIABILITY OR PATENT IS ASSUMED IN NO EVENT SHALL TEEJET TECHNOLOGIES BE LIABLE FOR ANY LOSS OF BUSINESS LOSS OF PROFIT LOSS OF USE OR DATA INTERRUPTION OF BUS...

Страница 5: ...ce the display reveals the application rate automatically switches between target and actual pressure speed and area covered Individual Boom Controls give independent control of up to five boom sectio...

Страница 6: ...and 2 are shown as general guidelines to follow when plumbing the 844 components The type of pump used and location of other components can vary from sprayer to sprayer It is important to ensure that...

Страница 7: ...he boom control valves If you choose this location the 844 will need to be properly programmed to reverse the polarity of the valve This step can be found in the System Setup instructions on page 14 W...

Страница 8: ...uction manual of the valves you are using for valve calibration instructions Pressure Transducer The pressure transducer if used should be installed as close to the spray tips as possible Normally thi...

Страница 9: ...errors that are likely to occur from a slipping drive wheel Refer to Figure 5 Proximity Sensor optional An optional proximity sensor is available to use in cases where space is limited or for drive s...

Страница 10: ...n driven wheel The round right angle steel bracket is then secured to the flat bracket with the two U bolts and necessary hardware provided The round right angle bracket is then used to secure the mag...

Страница 11: ...e sensor end cable An adapter cable will be necessary when using most radars and are available through your TeeJet Technologies dealer The 844 will automatically sense if the speed sensor is a wheel s...

Страница 12: ...er boom switch in a convenient location i e on the throttle gear shift or floor switch To install a remote boom switch simply install a switch to the brown wire in the power cable The switch should be...

Страница 13: ...ore installing the sprayer components to be sure the cables are long enough in length from the sensor connections to the 844 console connection If your installation requires longer cables several exte...

Страница 14: ...ong the flow line main frame of the sprayer or wherever the cables can be conveniently secured Avoid any situation where the cables may lay in puddles or come in contact with extreme heat sources Warn...

Страница 15: ...both the flow meter and pressure transducer are not used simultaneously there will be one extra connection on the cable Simply tie this part of the cable back as it will not be used When all connecti...

Страница 16: ...olor Signal Name A Brown Power Out B White Flow Signal C Green Sensor Ground Figure 20 Regulator Connector Regulator Connector Pin No Wire Color Signal Name 1 White Regulation Valve 2 Brown Regulation...

Страница 17: ...amming steps will likely only need to be programmed once to customize the controller to your sprayer For either setup mode if you press and hold the Program key for three 3 seconds your inputs will be...

Страница 18: ...gram Units step again using the key and change back to your desired units Select no again at the Reset Defaults step and exit the program mode by pressing and holding the key for three 3 seconds Senso...

Страница 19: ...inches cm in SI mode If the default value is correct press the Program key to accept the value If the nozzle spacing is different than that shown as a default then add or reduce this number by using t...

Страница 20: ...ow rate will be automatically displayed at 40 psi 2 bar This pressure must be used for determining your tip s flow rate Actual operation pressure is not important When the correct nozzle flow rate has...

Страница 21: ...to optimize system performance If you notice that the valve seems to search for the programmed application rate by cycling the pressure up and down continuously reduce the number until the searching i...

Страница 22: ...the display The speed sensor is now properly calibrated NOTE Once the auto calibration mode has been activated no other functions of the 844 are possible until the console receives speed impulses for...

Страница 23: ...e is set press the Program key to advance to the next step The simulated speed will be activated after you exit the system setup mode NOTE Once the sprayer begins moving and the 844 receives actual sp...

Страница 24: ...SECONDS AND THE ENTIRE PROGRAM SYSTEM WILL BE STORED IN THE COMPUTER S MEMORY NOTE For your protection the 844 console will not automatically power down while in the System Setup Mode You must exit p...

Страница 25: ...other display parameters The table at the bottom indicates flow rates in US Gallons Per Minute Liters per Minute Imperial Gallons Per Minute at 40 psi 2 bar for the TeeJet VisiFlo color coded spray ti...

Страница 26: ...pecific Gravity Density Step in the System Setup Mode page 14 press the Auto Manual key When calculations are using the programmed Specific Gravity Density the D symbol will be displayed at the top of...

Страница 27: ...operation and to diagnose spray tip wear Worn tips can contribute to costly chemical waste and inaccurate spraying regardless of your use of a sprayer control Calibration is important and necessary t...

Страница 28: ...le spacing on page 15 The volume measure is dependent on flow meter pulses and is available on flow based models only The lower right of the display window will alternately show the treated area spray...

Страница 29: ...printer has power Simultaneously press and hold the Plus key and Minus key for three seconds or until the printer begins printing When the printer is finished the area and volume counters in the lower...

Страница 30: ...lication Rate and Actual Application Rate Check all components and programming steps related to flow Mechanical B Stalled meter pulses Make sure there is no pressure in the system Remove the flow mete...

Страница 31: ...ve Speed Number in the System Setup Mode page 17 to a slower value Plumb the regulating valve in bypass mode This should allow the regulating valve to operate more in the center of its rotation If you...

Страница 32: ...might be necessary to recalibrate the flow meter Follow the flow meter calibration procedure s on pages 30 32 of this manual E Speed sensor installed incorrectly One or more of the wheel sensor magnet...

Страница 33: ...make sure at least one boom section switch is on and pump exactly n 10 US gallons 38 liters 8 Imperial gallons through the flow meter When the known volume is reached shut the Master boom switch OFF...

Страница 34: ...d flow Step 5 Adjustments If the measured flow does not match the calculated flow the flow meter number may need to be adjusted If the measured flow is higher than the calculated flow the flow meter c...

Страница 35: ......

Страница 36: ...g ease of use Large back lit display shows all spraying information at a glance Color coded tip selection for easy programming Communication Port for PC and GPS interfacing Flow or pressure based regu...

Отзывы: