16
SECTION 7
RECOMMENDED MAINTENANCE
CONTROL PANEL
Monthly:
•
Check that all indicator lights work. Replace lamps as required.
•
Check all ribbon cable connections. Reinsert any partially inserted connectors.
•
Check all other cable type connections. Reinsert any partially inserted connectors.
Every 6 Months:
•
Retighten all screw terminal connections to insure proper bonding.
•
Check all control relays to see that they are properly connected.
Every 12 Months:
•
Check calibration of any controls that required calibration. Calibrate as required. See individual control compo-
nent manuals for calibration procedures.
PNEUMATIC CONNECTIONS
Monthly:
•
Check all pneumatic connections for leaks and tighten or replace as needed.
•
Check system main air pressure as specified. Adjust to required pressure if necessary.
Every 6 Months:
•
Tighten all screw terminal connections to insure proper bonding.
Every 12 Months:
•
Check component calibration and re
-
calibrate if required. See individual control component manuals for calibra-
tion procedures.
LIQUID CONTROLS
Monthly:
•
Check all liquid connections for leaks and repair or replace as required.
•
Check all tubes and/or hoses for leaks and repair or replace as required.
•
Check liquid components for leaks and repair or replace as required.
•
Check liquid in
-
line filters and replace with recommended filter mesh size for system.
SPRAY NOZZLES
Daily:
•
Check all spray guns for leaks or mechanical malfunctions. Repair or replace as required. See spray gun data sheet
for maintenance and repair details.
Monthly:
•
Clean, lubricate, and adjust all spray guns. See spray gun data sheet for maintenance and repair details.
Note:
Any long term shut
-
down requires that all liquid lines, liquid components, pumps, spray guns be flushed and
cleaned thoroughly.