94
Spohn & Burkhardt
9. Removal
Danger!
All tasks on the device are only allowed to be undertaken by specialist personnel taking
into account the relevant safety regulations. Always pay attention to the safety instruc-
Danger!
Transport the control stand using suitable hoisting equipment.
9.1. Disconnecting electrical connection
1. Disconnect the system from the supply of electrical power.
Figure 44.
18
18
18
14
15
15
14
15
15
14
15
15
53585
53577
49649
53678
53585
53577
Electrical connection: opening spacer
2. Open the spacer as per
section 3.2 “Electrical connection”, page 79, point 2 and 3.
Figure 45.
19
16
14
4
15
19
15
20
Undoing electrical connections
3. Undo the cables from the terminal block (
20
) and pull out the cables downward
.
4. Tip the control stand back and fasten the spacer (
4
) using the two locking screws (
19
).