![background image](http://html.mh-extra.com/html/spm/ipro-kit-autofill-post-mix/ipro-kit-autofill-post-mix_instruction-and-maintenance-manual_1349067009.webp)
Data di emissione:
Luglio, 2013
Revisione:
1
Pag. :
9/21
M
G
H
I
L
M
ELECTRONIC CONNECTION AND MACHINE START UP
Position the tap on the bowl in order to have it well inserted along all the perimeter;
Join the connector I of the power
supplier to one of the lids;
Connect the powered lid to the other
through the proper cable L, equipped
with a double connector (a potential
additional 3rd lid might be connected to
the second one);
Connect the plug G of the feeder to
electricity mains, the kit is now ready to
work;
WARNING!
During the first installation is necessary to
proceed with the manual refill of the
water and syrup hoses (see the paragraph
“
MANUAL DISPENSING OF WATER AND
SYRUP)
Switch the kit on by using the main
switch M located in the upper part of
the lid;
The kit will automatically start to fill the
bowl, till the reaching of the level fixed
by the probes.
The tap is provided with a security micro that
avoids the functioning both if the tap is lifted
during the charging phase and if the tap is not
well positioned on the bowl before starting it.
SIGNALLING
In case the product finishes or the water supply is interrupted, the autofill kit is equipped with
a system of acoustic and visual signals: the LED referring to the finished content starts
flashing, and uttering, at the same time, an acoustic warning signal.
In case the level probes are not working properly and the product reaches the short security
probe, the three LED will turn on simultaneously and the lid will utter an acoustic warning
signal until the machine will be switched off and the level issue will be solved.