background image

2

3

  s p m i n s t r u m e n t . c o m   |   i n f o @ s p m i n s t r u m e n t . s e

Technical specifications

Material, housing/lid: 

stainless steel EN 1.4523

Weight:  

approx. 300 g

Power supply,
   AIR14: 

non-rechargeable 3.6 VDC Lithium

   AIR15: 

24 V DC ±10 %, 400 mA

Power rating, AIR15: 

1.2 W 

Power connector, AIR15:  4-pin M12 male connector
Readings:  

RMS, peak, peak-to-peak, crest, kurt, skew,  

  

temperature

Spectrum lines:  

400, 800, 1600, 3200* lines

Measurement range,  

–20° to +85 °C (–4° to +185 °F)

temperature:  

(ac/– 2 °C)

Operating temperature:  –40 °C to +85 °C (–40 °F to +185 °F)
Storage temperature: 

–40 °C to +85 °C (–40 °F to +185 °F)

Maximum altitude:  

2000 m

Condition evaluation:  

ISO10816 Part 2, 3, 4 >600 rpm

Protection class: 

IP69

Relative humidity: 

0 to 100% (non-condensing)

LTE-M:  

LTE Cat M1 (300 kb/s DL, 375 kb/s UL). 

 

 

Multi-region, incl. bands 1, 2, 3, 4, 5, 8, 12, 13,  

 

 

18, 19, 20, 25, 26, 28

Nordic operator:  

Telia Sverige AB

Bluetooth:  

v4.2 BLE

Part numbers

AIR14-01  

Airius II LTE-M, battery powered, incl. subscription 

 

 

 

with 3 years of data**, 10-1000 Hz, 2/4/8 g

AIR14-10  

Airius II LTE-M, battery powered, incl. subscription

 

 

 

with 3 years of data**, 2-5000 Hz, 2/4/8/16 g

AIR15-01  

Airius II LTE-M, externally powered, incl. subscription

 

 

 

with 3 years of data**, 10-1000 Hz, 2/4/8 g

AIR15-10  

Airius II LTE-M, externally powered, incl. subscription

 

 

 

with 3 years of data**, 2-5000 Hz, 2/4/8/16 g

Accessories

18470 

Installation kit (installation foot, M4 screw,

 

 

M4 washer, M6 screw)

18471 

Installation kit (installation foot, M8 screw)

18466 

Installation foot, glue installation

18549   Power supply for testing AIR15 in an indoor 
 

 

environment (incl. Europlug, angled 4-pin M12 

 

 

female connector, and 1.8 m cable)

MOD1YB One year of additional data for AIR14**
MOD1YC One year of additional data for AIR15**
MOD3YB Three years of additional data for AIR14**
MOD3YC Three years of additional data for AIR15**

Spare parts

18572 

Battery cell, Airius II

* 3200 lines are only available for AIR14-10 and AIR15-10. 

** Amount of data based on four measurements per day for AIR14 

and 24 measurements per day for AIR15.

152.5

AIR14

Ø45

AIR15

152.5

20

Ø45

15

12.6

16

Ø28

1

3

2

4

+

18466

Содержание AIR14-01

Страница 1: ...1 i n f o s p m i n s t r u m e n t s e QUICKSTART Airius II LTE M ...

Страница 2: ...rument com Technical data subject to change without notice ISO 9001 certified SPM 2021 10 72328 B Rev 0 Contents Technical specifications 3 Mechanical installation Airius vibration sensors 4 Setting up Airius 5 Setting up vibration measurements in Condmaster Ruby 7 Setting up vibration measurements in Condmaster NET 9 Replacing battery 10 ...

Страница 3: ...iption with 3 years of data 10 1000 Hz 2 4 8 g AIR14 10 Airius II LTE M battery powered incl subscription with 3 years of data 2 5000 Hz 2 4 8 16 g AIR15 01 Airius II LTE M externally powered incl subscription with 3 years of data 10 1000 Hz 2 4 8 g AIR15 10 Airius II LTE M externally powered incl subscription with 3 years of data 2 5000 Hz 2 4 8 16 g Accessories 18470 Installation kit installatio...

Страница 4: ...allation foot See table for sensor torque 6 If necessary adjust the installation foot so that the sensor s markings align with the intended measurement directions 7 If installing AIR15 connect an M12 connector to power the sensor Glue installation 1 Drill a counterbore with 30 mm diameter on the machine where the sensor should be placed 2 Screw the sensor onto the installation foot Tightening torq...

Страница 5: ...n flashing means that the sensor is working When the connection to Condmaster Entity Server CES is successful the sensor flashes green The number of green flashes corresponds to the LTE M signal strength 1 flash poor 2 flashes average 3 flashes good If the connection is unsuccessful the sensor flashes red 1 flash could not connect to the server 2 flashes invalid subscription contact your sales rep...

Страница 6: ...6 s p m i n s t r u m e n t c o m ...

Страница 7: ...technique Vibration 2 or 3 channel vibration or ISO 10816 and click Add 9 Select Online under Instrument select settings as desired and click OK 10 Go to the Online tab select the Airius sensor and direction z x or y under Address Click OK 11 Go to the Settings tab name the assignment and edit the settings as desired 12 For settings regarding conditions and filtering of results go to the Online Ad...

Страница 8: ...8 s p m i n s t r u m e n t c o m ...

Страница 9: ...tails 10 Click Create 11 Select a name for the measuring assignment 12 Select an Airius sensor under Measuring unit 13 To edit measuring interval operational hours or measuring range for the Airius sensor click Edit unit settings 14 Mark the axes z x y to be measured 15 Select frequency range 16 Select spectrum unit 17 Set alarm limit for each condition parameter that should have an alarm limit 18...

Страница 10: ...terfere with the battery replacement The lid is attached to the antenna cable that is attached to the circuit board at the other end 2 Loosen the two screws and remove the battery cover 3 Remove the battery and disconnect the plug 4 Connect the plug and insert the new battery 18572 5 Screw on the battery cover Tightening torque 0 5 Nm 6 Put the O ring in place and screw on the lid Tightening torqu...

Страница 11: ...aste and is marked with a crossed out wheeled bin symbol in order to prevent it being discarded with household waste When the life cycle of the product is over You can return it to Your local SPM representative for correct treatment or dispose it together with your other electronic waste ...

Страница 12: ...12 s p m i n s t r u m e n t c o m ...

Отзывы: