6
7
s p m i n s t r u m e n t . c o m | i n f o @ s p m i n s t r u m e n t . s e
Setting up vibration measurements in Condmaster Ruby
1. Go to
Graphical Overview
>
View as tree
.
2. In the tree structure to the left, expand
Components
.
3. Right-click Components, choose Create, and click
Component
.
4. Enter component number and name.
5. Click
Save
.
6. Right-click the created component, choose Create, and click
Measuring point
.
7. Enter Measuring point number and name.
8. Select a vibration measurement technique (Vibration, 2 or 3 channel vibration, or ISO 10816) and click
Add
.
9. Select
Online
under Instrument, select settings as desired, and click
OK
.
10. Go to the
Online
tab, select the Airius sensor and direction (z, x, or y) under Address. Click
OK
.
11. Go to the
Settings
tab, name the assignment, and edit the settings as desired.
12. For settings regarding conditions and filtering of results, go to the
Online Advanced
tab.
13. Go to
RPM
and enter fixed or variable speed (as a global value).
14. Click
Save
.
For further information regarding these steps, see chapter
Settings up measuring assignments for Airius vibration
sensors
in the
Condmaster Ruby User Guide
.